330400-01-00

Accelerometer Acceleration Transducers

Product Information:

330400 and 330425 Accelerometer

Acceleration Transducers

The 330400 is designed to address the requirements of

American Petroleum Institute Standard 670 for accelerometers

+20 to +30 °C (+68 to +86 °F) and 100 Hz

Expand All
Collapse all

Technical specifications for 330400-01-00

  • Manufacturer:
    Bently Nevada
  • Product Category:
    TSI System
  • Estimated shipping dimensions:
    5.9 x 2.3 x 2.3 cm
  • Weight:
    0.1 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Sensitivity:
    10.2 mV/m/s2 (100 mV/g) ±5%
  • Acceleration range:
    490 m/s2 (50 g) peak
  • Amplitude Linearity:
    ±1% to 490 m/ s2 (50 g) peak
  • Broadband Noise Floor (10 Hz to 15 kHz):
    0.039 m/s2 (0.004 g) rms
  • Mounting Thread:
    ¼-28 UNF integral stud
  • Agency Approval:
    None

Ask our team:

Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.