Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
IC697CPX935 is a GE cpu, 96 mhz, 12k discrete i/o, 1m byte fixed user memory used within the GE Fanuc Series 90-70 PLC architecture. It provides the specified cpu, 96 mhz, 12k discrete i/o, 1m byte fixed user memory function while retaining the complete order code, hardware execution and receiving-system compatibility during replacement. Its documented hardware role is CPU, 96 MHz, 12K Discrete I/O, 1M byte fixed user memory.
Verify that the supplied item is marked IC697CPX935 and that its cpu, 96 mhz, 12k discrete i/o, 1m byte fixed user memory form, connectors and revision agree with the approved GE 90-70 Series PLC receiving record.
For IC697CPX935, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.
Apply only parameters supported by the exact IC697CPX935 record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.
IC697CPX935 technical scope: System Platform: GE Fanuc Series 90-70 PLC architecture; Functional Role: CPU, 96 MHz, 12K Discrete I/O, 1M byte fixed user memory function in the documented GE Fanuc Series 90-70 architecture; Hardware Format: rack PLC, CPU, I/O or communication module; Product Type: CPU, 96 MHz, 12K Discrete I/O, 1M byte fixed user memory; Series: GE 90-70 Series PLC.
Use these values only for the listed hardware execution and verify the supplied label before installation.
Match IC697CPX935 to the approved GE 90-70 Series PLC receiving position, connector or terminal arrangement and configuration record.
After power restoration, review diagnostics and test the affected cpu, 96 mhz, 12k discrete i/o, 1m byte fixed user memory path.
Obsolete/Discontinued by OEM
IC697CPX935 is a General Electric cpu, 96 mhz, 12k discrete i/o, 1m byte fixed user memory associated with the GE 90-70 Series PLC platform. It interfaces the documented field signals with the control system through the assigned channels, terminals and installed I/O position. Correct selection depends on the complete model code, connector or terminal arrangement, hardware revision and receiving-system configuration. Before replacement, compare the original product label, installed slot or cabinet reference, connected assemblies and approved project records. After installation, review system diagnostics and function-test every affected channel, control path, protection function or communication link before returning the equipment to service.