Overview
Manuals
Small-Shaft Monitoring
Compressor Equipment
Probe Gap
Features:
- Metric M10 × 1 probe configuration with stainless-steel armor for mechanically demanding installations.
- The specified configuration provides a 1.0 m total probe length with a 100 mm case.
- The probe uses a miniature coaxial ClickLoc connector with connector protector and is configured with the Multiple Approvals option.
The Bently Nevada 330910-00-10-10-01-05 is part of the 3300 XL NSv proximity transducer system, a non-contact eddy-current measurement system designed for machinery where conventional proximity-probe installation is restricted by counterbore, side-view, rear-view, or target-size limitations. The NSv system can be used for radial vibration, radial position, axial/thrust position, tachometer or zero-speed measurement, and Keyphasor phase-reference applications on fluid-film bearing machinery.
This specific probe combines an M10 × 1 threaded case, 100 mm case length, 1.0 m total length, armored probe cable, ClickLoc connector with protector, and Multiple Approvals. The 3300 XL NSv system provides a 1.5 mm linear range, a recommended 1.0 mm gap setting, and an average scale factor of 7.87 V/mm (200 mV/mil) under the manufacturer's specified test conditions.
The 330910-00-10-10-01-05 Bently Nevada Proximity Probe may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Bently Nevada 330910-00-10-10-01-05 Standard Interconnect Cables Manuals(Datasheets), Link
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Suitable for applications involving relatively small targets, including radial vibration measurements on shafts below 51 mm and axial-position measurements on flat targets below 15 mm.
The NSv system is intended for applications including centrifugal air compressors, refrigeration compressors, process-gas compressors, and other machines with tight installation requirements.
The manufacturer's recommended probe gap is 1.0 mm (40 mils). The specified system linear range is approximately 0.25 to 1.75 mm (10 to 70 mils).