Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
9200-03-05-10-00 is a Bently Nevada two-wire transducer used within the Bently Nevada machinery monitoring system. It provides the specified two-wire transducer function while retaining the complete order code, hardware execution and receiving-system compatibility during replacement. Its documented transducer mounting angle/minimum operating frequency option is 90 ±2.5, 4.5 Hz (270 cpm).
Measurement Role: 9200-03-05-10-00 performs the two-wire transducer function within the Bently Nevada transducer and transmitter products. The retained documentation identifies transducer mounting angle/minimum operating frequency option as 90 ±2.5, 4.5 Hz (270 cpm); apply that value only to this documented execution.
Match the complete label, hardware form and functional position before transferring any setting, cable or termination from the removed unit.
Integration Review: approve 9200-03-05-10-00 only for the documented Bently Nevada machinery monitoring system. Compare rack, carrier or panel generation, connector keying, terminal numbering and all paired assemblies with the installation drawings.
Photograph both sides and the installed position before removal so revision markings, jumpers, addressing and channel allocation can be reconstructed accurately.
Startup Review: isolate the equipment, remove stored energy and inspect the receiving hardware before installing 9200-03-05-10-00.
Restore power in the approved sequence, review status and diagnostics, then test every affected control, signal, relay, communication, protection or monitoring path against the commissioning record.
Verify that the supplied item is marked 9200-03-05-10-00 and that its two-wire transducer form, faceplate, connectors and printed revision agree with the approved Bently Nevada transducer and transmitter products receiving record.
Retained product evidence for this execution includes Transducer Mounting Angle/Minimum Operating Frequency Option: 90 ±2.5, 4.5 Hz (270 cpm); Connector/Cable: Terminal block top mount (no cable). Use photographs of the label and installed position to resolve ambiguity before shipment or installation.
For 9200-03-05-10-00, provide the installed Bently Nevada machinery monitoring system, required condition, quantity, receiving slot or mounting position and every connected terminal, cable or carrier assembly.
Record revision restrictions, configuration or calibration dependencies, testing requirements and required certificates so the quoted two-wire transducer matches the maintenance scope.
Confirm the current OEM lifecycle stage for 9200-03-05-10-00 against manufacturer records at quotation. The supplied two-wire transducer is matched by its complete hardware identity, revision and included assemblies.
Any alternative is proposed only after the receiving Bently Nevada machinery monitoring system, interfaces, configuration dependencies and commissioning requirements have been reviewed.