Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
KJ3002X1-BG2 12P1731X022 VE4003S5B1 is a Emerson thermocouple/rtd module used within the Emerson DeltaV distributed control system. It provides the specified thermocouple/rtd module function while retaining the complete order code, hardware execution and receiving-system compatibility during replacement. Its documented localbus power rating is 12 VDC at 350 mA.
Hardware Role: KJ3002X1-BG2 12P1731X022 VE4003S5B1 performs the thermocouple/rtd module function within the Emerson DeltaV. The retained documentation identifies localbus power rating as 12 VDC at 350 mA; apply that value only to this documented execution.
Match the complete label, hardware form and functional position before transferring any setting, cable or termination from the removed unit.
Platform Fit: approve KJ3002X1-BG2 12P1731X022 VE4003S5B1 only for the documented Emerson DeltaV distributed control system. Compare rack, carrier or panel generation, connector keying, terminal numbering and all paired assemblies with the installation drawings.
Photograph both sides and the installed position before removal so revision markings, jumpers, addressing and channel allocation can be reconstructed accurately.
Operational Test: isolate the equipment, remove stored energy and inspect the receiving hardware before installing KJ3002X1-BG2 12P1731X022 VE4003S5B1.
Restore power in the approved sequence, review status and diagnostics, then test every affected control, signal, relay, communication, protection or monitoring path against the commissioning record.
Verify that the supplied item is marked KJ3002X1-BG2 12P1731X022 VE4003S5B1 and that its thermocouple/rtd module form, faceplate, connectors and printed revision agree with the approved Emerson DeltaV receiving record.
Retained product evidence for this execution includes LocalBus power rating: 12 VDC at 350 mA; Field circuit rating: 5.5 VDC at 0.6 mA/channel. Use photographs of the label and installed position to resolve ambiguity before shipment or installation.
For KJ3002X1-BG2 12P1731X022 VE4003S5B1, provide the installed Emerson DeltaV distributed control system, required condition, quantity, receiving slot or mounting position and every connected terminal, cable or carrier assembly.
Record revision restrictions, configuration or calibration dependencies, testing requirements and required certificates so the quoted thermocouple/rtd module matches the maintenance scope.
Confirm the current OEM lifecycle stage for KJ3002X1-BG2 12P1731X022 VE4003S5B1 against manufacturer records at quotation. The supplied thermocouple/rtd module is matched by its complete hardware identity, revision and included assemblies.
Any alternative is proposed only after the receiving Emerson DeltaV distributed control system, interfaces, configuration dependencies and commissioning requirements have been reviewed.