The General Electric IC695ACC302 is an industrial automation component for the PACSystems RX3i platform. It performs its documented equipment function within the installed industrial system. Confirm the complete model code, hardware revision, interfaces and supplied condition against the installed equipment before replacement.
Verify that the supplied item is marked IC695ACC302 and that its auxiliary smart battery module for pacsystems. provides low battery signal to the cpu. module mounts external to the controller. form, connectors and revision agree with the approved PACSystems RX3i receiving record.
For IC695ACC302, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.
Apply only parameters supported by the exact IC695ACC302 record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.
IC695ACC302 technical scope: Program storage: Up to 10 Mbytes battery-backed RAM; 10 Mbytes non-volatile flash user memory; Power requirements: +3.3 VDC: 1.25 Amps nominal +5 VDC: 1.0 Amps nominal; Operating Temperature: 0 to 60°C (32°F to 140°F); Boolean execution speed: 0.195ms per 1000 Boolean instructions, typical; Elapsed Time Clock (internal timing) accuracy: 0.01% maximum.
Use these values only for the listed hardware execution and verify the supplied label before installation.
Match IC695ACC302 to the approved PACSystems RX3i receiving position, connector or terminal arrangement and configuration record.
After power restoration, review diagnostics and test the affected auxiliary smart battery module for pacsystems. provides low battery signal to the cpu. module mounts external to the controller. path.
Active / Available from OEM
IC695ACC302 is a General Electric auxiliary smart battery module for pacsystems. provides low battery signal to the cpu. module mounts external to the controller. associated with the PACSystems RX3i platform. It supports the documented controller execution, communications and configuration functions assigned to the installed processor position. Correct selection depends on the complete model code, connector or terminal arrangement, hardware revision and receiving-system configuration. Before replacement, compare the original product label, installed slot or cabinet reference, connected assemblies and approved project records. After installation, review system diagnostics and function-test every affected channel, control path, protection function or communication link before returning the equipment to service.