The General Electric IC695CMM004 is an industrial automation component for the PACSystems RX3i platform. It performs its documented equipment function within the installed industrial system. Confirm the complete model code, hardware revision, interfaces and supplied condition against the installed equipment before replacement.
Verify that the supplied item is marked IC695CMM004 and that its rx3i serial communications module. four isolated rs-232/485 port. supports serial read/write and modbus master/slave. requires unversal backplane. form, connectors and revision agree with the approved PACSystems RX3i receiving record.
For IC695CMM004, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.
Apply only parameters supported by the exact IC695CMM004 record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.
IC695CMM004 technical scope: Baud rates: 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2k; Data bits: 7, 8; Stop bits: 1, 2; Operating Temperature: 0°C to + 60°C; Input Impedance: Zin > 96 kOhm for RS-485/422 3 kOhm < Zin < 7 kOhm for RS-232.
Use these values only for the listed hardware execution and verify the supplied label before installation.
Match IC695CMM004 to the approved PACSystems RX3i receiving position, connector or terminal arrangement and configuration record.
After power restoration, review diagnostics and test the affected rx3i serial communications module. four isolated rs-232/485 port. supports serial read/write and modbus master/slave. requires unversal backplane. path.
Active / Available from OEM
IC695CMM004 is a General Electric rx3i serial communications module. four isolated rs-232/485 port. supports serial read/write and modbus master/slave. requires unversal backplane. associated with the PACSystems RX3i platform. It supports the documented industrial communication path between the controller, network and connected automation equipment. Correct selection depends on the complete model code, connector or terminal arrangement, hardware revision and receiving-system configuration. Before replacement, compare the original product label, installed slot or cabinet reference, connected assemblies and approved project records. After installation, review system diagnostics and function-test every affected channel, control path, protection function or communication link before returning the equipment to service.