Honeywell technical specifications

MU-PDOX02 51304487-100

Product Information:

Honeywell maps MU-PDOX02 to part 51304487-100 and identifies it as a CE-compliant, 16-point digital-output I/O processor in the TPS/HPM family. Output voltage, switching and terminal characteristics depend on the separately selected FTA. Confirm the installed processor, FTA, I/O configuration and physical label before replacement.

  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      MU-PDOX02 is Honeywell's 16-point digital-output I/O processor for the TPS High-Performance Process Manager family. Honeywell HPM Planning table 7-2 maps this exact model to 51304487-100 in its CE-compliant IOP part-number column. The Honeywell TPS Process Manager I/O specification labels MU-PDOX02 as a 16-point digital-output processor and shows separate compatible field termination assemblies. Depending on the selected FTA, the complete output arrangement may serve different AC, DC, relay or nonisolated circuits. Do not assign an FTA-specific load voltage, current, terminal type or relay contact rating to the processor alone. MU-PDOY22 is a distinct 32-point digital-output processor rather than an interchangeable execution. Match the installed IOP, FTA, channel assignment, cabinet and revision before ordering.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Selected industrial-control settings for this industrial communications hardware include Oil & Gas, Power Generation, Mining & Metals and Marine & Shipbuilding.

      Oil & Gas

      Applies to production, compression and processing assets using compatible industrial communications hardware, subject to engineering review of the installed control architecture.

      Power Generation

      Serves boiler, turbine and balance-of-plant systems using compatible industrial communications hardware, with site requirements and the supplied revision confirmed.

      Mining & Metals

      Supports mineral processing and metals-production equipment using compatible industrial communications hardware, after the installed configuration is confirmed.

      Marine & Shipbuilding

      Fits shipboard machinery and marine utility systems using compatible industrial communications hardware, when exact hardware and system compatibility are verified.
Technical specifications for

MU-PDOX02 51304487-100

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • OEM part number:
    51304487-100 (CE-compliant entry in Honeywell HPM Planning table 7-2)
  • Hardware role:
    Digital-output I/O processor (IOP)
  • System family:
    Honeywell TPS/HPM Process Manager I/O
  • Output points:
    16; IOP comparison and FTA matrix
  • Separate FTA:
    Required for field termination; choose the documented output type
  • Example AC FTA:
    MU-TDOA13, 120/240 Vac solid-state output
  • Other FTA families:
    Documented DC solid-state, nonisolated and relay variants
  • Distinct processor:
    MU-PDOY22 is a separate 32-point DO processor
  • Approval entry:
    CE-compliant entry in Honeywell 1998 parts table
  • Output Type:
    Open-collector (current-sinking) NPN transistors
  • Maximum Load Current:
    100 mA per output
  • Minimum Load Current:
    1 mA per output
  • Output Isolation:
    None (any screw terminal to common)
  • Product Type:
    Digital Output Module
  • System Platform:
    Honeywell Experion PKS and Series C I/O
  • Turn-on/Turn-off Time:
    10 µs
  • Product Series:
    Honeywell Series C / Experion PKS
  • Hardware Format:
    control-system module or termination assembly
  • Stock Availability:
    2
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

MU-PDOX02 MUPDOX02 Honeywell MU-PDOX02 51304487-100

Information

Overview Manuals Exact IOP Identity Processor Versus FTA Replacement Boundary

Features:

  • Honeywell HPM Planning directly maps MU-PDOX02 to 51304487-100.
  • Honeywell IO03-684 identifies the IOP as a 16-point digital-output processor.
  • The manufacturer matrix documents multiple separate output FTA categories.

Honeywell's March 1998 HPM Planning parts table lists MU-PDOX02 as a digital-output IOP and assigns 51304487-100 in the CE-compliant part-number column. The TPS Process Manager I/O specification describes it as the digital-output 16-point processor. Its comparison table distinguishes this processor from MU-PDOY22, which is the 32-point version. These documents establish the processor's identity and output-channel count, not a universal load-voltage rating. The field termination assembly chosen for the installation determines the relevant terminal and load interface.

The Honeywell IOP/FTA compatibility matrix lists MU-PDOX02 with several 16-point field termination choices, including 120/240 Vac solid-state MU-TDOA13, DC solid-state FTAs and relay FTAs. Electrical limits in the FTA specification must be attributed to the selected output path, not automatically to every MU-PDOX02 installation. Before replacement, document the processor label, revision, cabinet position, configured point assignments, installed FTA, field supply, fuse arrangement and connected loads. Use current site procedures and manufacturer instructions for isolation, fitting and channel-by-channel verification. Historical documentation does not prove current inventory or unrestricted interchangeability.

The MU-PDOX02 51304487-100 Honeywell HPM 16-Point Digital Output Processor may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell MU-PDOX02 51304487-100 official technical documentation and product links.This multi-page Honeywell technical document contains the exact model and its technical data. Apply the values to the supplied type number and verify its revision before installation.

The Honeywell HPM Planning parts table prints MU-PDOX02 and 51304487-100 on the same digital-output IOP row, under the CE-compliant part-number column. That is direct exact-model evidence for the website identity. It does not establish the installed item's revision, condition or firmware compatibility. Verify the physical label and the plant's HPM hardware records before treating an offered processor as the correct spare.

MU-PDOX02 is the 16-point digital-output processor, while the compatible FTA provides a separately specified field interface. Honeywell lists AC solid-state, DC solid-state, nonisolated and relay FTA arrangements for the processor. A voltage or contact rating from one FTA cannot be copied to all others. Confirm the exact companion FTA model, field supply and wiring before selecting electrical specifications or conducting output tests.

A Honeywell comparison table separately names the 32-point MU-PDOY22 processor, so it should not be substituted on name similarity. For MU-PDOX02, record the full part label, slot, cabinet generation, software configuration and point assignments. Check the paired termination assembly and field circuits using approved drawings. Follow local isolation and return-to-service procedures, then verify all affected outputs and diagnostics before releasing the process equipment.

Technical notes

Honeywell HPM Planning (March 1998) PDF page 134: MU-PDOX02 maps to CE-compliant 51304487-100. Honeywell IO03-684 pages 43, 53 and 58: separate 16-point DO processor and FTA compatibility. FTA-specific electrical ratings are not blanket processor ratings.

Hardware and System Match

Confirm MU-PDOX02 and 51304487-100 on the supplied processor label. Match the HPM cabinet, I/O position, release, board revision and configured 16-point output database. Honeywell's parts table identifies the CE-compliant IOP entry. Its I/O specification lists multiple companion FTAs with different load technologies, so select the exact installed FTA before interpreting voltage, current, isolation, terminal and fuse data. The processor is not itself the field termination assembly.

Controlled Commissioning

Capture the existing slot identity, IOP revision, FTA designation, field power, fuses, point names, command states and diagnostic history. Isolate circuits under the plant's authorized maintenance procedure and follow current Honeywell installation guidance. After fitting the verified IOP, inspect seating and connections, restore the approved configuration, then prove each affected output through its actual FTA and load under a controlled test plan. Do not assume the 32-point MU-PDOY22 or another PDOX revision is a drop-in replacement without documented approval.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    Bare-item dimensions from the exact-model warehouse image record: 2.9 x 31.7 x 27.8 cm. Final packed dimensions include accessories and protective packaging.
  • Packed shipping weight
    Confirmed after final packing
    Bare-item weight from the exact-model warehouse image record: 0.68 kg. Final packed weight includes accessories and protective packaging.
  • HS / customs code
    8538900000 (indicative reference)
    Indicative reference for an industrial control-system input/output part; the destination declarant confirms the final classification from the supplied item and shipment evidence.
  • Country of origin
    Confirm from supplied item
    Use its marking or traceable shipment documents.
  • Ships from
    Xiamen, Fujian, China
    Dispatch details are confirmed in the quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about MU-PDOX02 51304487-100

  • What should be checked before ordering MU-PDOX02?

    Verify the processor part label, 16-point configuration, cabinet and companion FTA.
  • Does Honeywell map 51304487-100?

    Yes. HPM Planning table 7-2 maps it to MU-PDOX02.
  • Is this a field termination assembly?

    No. It is the I/O processor; the FTA is separate.
  • How many output points are listed?

    Honeywell identifies MU-PDOX02 as a 16-point processor.
  • Does it have one universal load voltage?

    No. The selected companion FTA determines the field-load interface.
  • Is MU-PDOY22 the same processor?

    No. Honeywell identifies it as a separate 32-point output processor.
  • Can any FTA be fitted?

    No. Use the manufacturer compatibility matrix and installed system drawings.
  • How are shipping details confirmed?

    Final package measurements, weight and document scope are confirmed in writing.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Obsolete/Discontinued by OEM

    Moore Automated supplies genuine-quality Honeywell MU-PDOX02 51304487-100 industrial automation component for maintenance and replacement of compatible installed systems. Every unit is carefully inspected before shipment, supporting dependable control-system maintenance and minimizing unexpected production downtime.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

MU-PDOX02 51304487-100
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.