REA101-AA RLY-REA101-AAAG is an ABB arc protection relay used with the documented Safety Automation platform. Selection must match the complete product identity, hardware execution, connected assemblies and approved system configuration.
Before replacing REA101-AA RLY-REA101-AAAG, compare the supplied nameplate, revision, connectors or terminals and installed position with the original equipment record. After installation, review diagnostics and complete the approved functional checks before service.
ABB REA101-AA RLY-REA101-AAAG documentation and reference links.
Important Notice: Every linked document must identify the listed model or its documented family. Confirm the complete order code, hardware revision and installed-system requirements before replacement.
REA101-AA RLY-REA101-AAAG is a ABB arc protection relay for the ABB REA arc protection system. The documented identity places it in the ABB REA product family and defines its role as arc protection relay within the installed control or monitoring architecture.
The listed parameters are limited to the documented model or product-family evidence. Do not import ratings from a similar part number; compare the exact label, slot or carrier, terminal map and connected equipment.
REA101-AA RLY-REA101-AAAG must remain matched to the documented ABB REA arc protection system installation. Confirm the receiving hardware generation, connector or terminal arrangement, software or configuration dependencies and system drawings before approving the item.
Photograph labels and connections before removal and preserve the original position, keying, addressing and channel allocation.
Isolate the equipment using the approved procedure, verify all stored energy is removed and inspect the receiving hardware before fitting REA101-AA RLY-REA101-AAAG.
After installation, restore power in the documented sequence, review diagnostics and test every affected signal, relay, network, control or protection function against the commissioning record.
Inspect the supplied arc protection relay for REA101-AA RLY-REA101-AAAG against the documented product record. Confirm Rated voltage: 250 V DC/AC and Continuous carry: 5 A, then check the label, housing, connectors and mounting points for the exact installed execution.
Before returning REA101-AA RLY-REA101-AAAG to service, preserve Minimum pulse length: 1 s and Service temperature range: -35...+80°C from the installed arrangement. After fitting the item, exercise each documented output with a controlled load and confirm channel indication and fail-state behavior; record the result with the maintenance history.