Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China

REA107-AA RLY-REA107-AAA is an ABB arc protection extension unit used with the documented Safety Automation platform. Selection must match the complete product identity, hardware execution, connected assemblies and approved system configuration.
Before replacing REA107-AA RLY-REA107-AAA, compare the supplied nameplate, revision, connectors or terminals and installed position with the original equipment record. After installation, review diagnostics and complete the approved functional checks before service.
ABB REA107-AA RLY-REA107-AAA documentation and reference links.
Important Notice: Every linked document must identify the listed model or its documented family. Confirm the complete order code, hardware revision and installed-system requirements before replacement.
REA107-AA RLY-REA107-AAA is a ABB arc protection extension unit for the ABB REA arc protection system. The documented identity places it in the ABB REA product family and defines its role as arc protection extension unit within the installed control or monitoring architecture.
The listed parameters are limited to the documented model or product-family evidence. Do not import ratings from a similar part number; compare the exact label, slot or carrier, terminal map and connected equipment.
REA107-AA RLY-REA107-AAA must remain matched to the documented ABB REA arc protection system installation. Confirm the receiving hardware generation, connector or terminal arrangement, software or configuration dependencies and system drawings before approving the item.
Photograph labels and connections before removal and preserve the original position, keying, addressing and channel allocation.
Isolate the equipment using the approved procedure, verify all stored energy is removed and inspect the receiving hardware before fitting REA107-AA RLY-REA107-AAA.
After installation, restore power in the documented sequence, review diagnostics and test every affected signal, relay, network, control or protection function against the commissioning record.
Inspect the supplied arc protection extension unit for REA107-AA RLY-REA107-AAA against the documented product record. Confirm Maximum system voltage: 250 V dc/ac and Normal service temperature range: -40... +100 °C, then check the label, housing, connectors and mounting points for the exact installed execution.
Before returning REA107-AA RLY-REA107-AAA to service, preserve Operating time from the light: < 1.0 ms and Degree of protection, IEC 60529: IP 20 from the installed arrangement. After fitting the item, exercise each documented output with a controlled load and confirm channel indication and fail-state behavior; record the result with the maintenance history.