BASLER ELECTRIC AVC63-12A1
BASLER ELECTRIC AVC63-12A1
BASLER ELECTRIC AVC63-12A1
BASLER ELECTRIC AVC63-12A1
BASLER ELECTRIC AVC63-12A1
BASLER ELECTRIC AVC63-12A1
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Thursday, November 5
Fast Shipping Available
Automatic Voltage Regulator

AVC63-12A1

Product Information:

AVC63-12A1 is a Basler Electric automatic voltage regulator for brushless synchronous generator excitation. It provides 63 Vdc at 12 Adc continuous output, supports 100/120 Vac sensing at 50/60 Hz and includes frequency compensation, overexcitation protection and parallel-droop compensation.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      Basler Electric AVC63-12A1 is an analog automatic voltage regulator for the excitation field of conventional brushless synchronous generators. The complete style code identifies the AVC63-12 model with 63 Vdc at 12 Adc maximum continuous output, A sensing for nominal 100/120 Vac and style 1 for 50/60 Hz sensing. The official manual lists 90 to 153 Vac power input, 90 to 139 Vac sensing for option A, single- or three-phase sensing and power input, 1 or 5 A CT input, and a plus or minus 3 Vdc accessory input. Match the complete style code, generator excitation design, sensing voltage, frequency, CT circuit and terminal wiring before replacement.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      This regulator is used in qualified brushless synchronous-generator excitation systems whose power, sensing, field and compensation circuits match the complete AVC63-12A1 style.

      Power Generation

      Generator-voltage regulation in qualified standby, prime-power and utility generating units.

      Data Centers

      Excitation control for documented emergency and standby generator systems serving critical facilities.

      Marine

      Voltage regulation in approved marine auxiliary and shipboard generator installations.

      Oil & Gas

      Generator excitation in qualified production, pipeline and remote-power facilities.
Technical specifications for

AVC63-12A1

0 TECHNICAL PARAMETERS
  • Manufacturer:
    BASLER ELECTRIC
  • Product Category:
    General Automation
  • Product function:
    Analog automatic voltage regulator for brushless synchronous generators
  • Style code A1:
    100/120 Vac sensing, 50/60 Hz
  • Maximum continuous output:
    63 Vdc at 12 Adc
  • 10-second forcing output:
    125 Vdc at 24 Adc
  • Power input:
    90 to 153 Vac, single or three phase, 50 to 400 Hz
  • Sensing input option A:
    90 to 139 Vac, single or three phase, less than 1 VA per phase
  • Current-transformer input:
    1 or 5 Aac at 50/60 Hz
  • Accessory input:
    Plus or minus 3 Vdc
  • Regulation accuracy:
    Plus or minus 0.5% of voltage setpoint, average response
  • Response time:
    Less than 4 ms
  • Minimum field resistance:
    5.25 ohms
  • Underfrequency compensation:
    One or two jumper-selectable V/Hz curves; 45 to 65 Hz knee range
  • Operating temperature:
    -40 to +70 degrees C
  • Stock Availability:
    2
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

Basler AVC63-12A1 AVC63 12A1 AVC63-12 A1 Basler AVC63-12 Voltage Regulator

Information

Overview Manuals Electrical Ratings Sensing Compensation Generator Setup

Features:

  • AVC63-12A1 style code selects 63 Vdc at 12 Adc output, 100/120 Vac sensing and 50/60 Hz.
  • Single- or three-phase sensing and shunt or PMG power input are supported within the documented limits.
  • Frequency compensation, overexcitation shutdown, droop compensation and accessory bias input are integrated.

AVC63-12A1 senses generator terminal voltage and controls dc field power to maintain the voltage setpoint. The regulator includes selectable underfrequency compensation, inverse-time overexcitation shutdown, voltage buildup circuitry and parallel-droop compensation.


Before removal, record every terminal connection, jumper, adjustment position, sensing transformer, CT polarity, field resistance, excitation source and generator operating data. After installation, complete the approved static checks and generator commissioning procedure before applying normal load.


The AVC63-12A1 BASLER ELECTRIC Automatic Voltage Regulator is listed as Active / Available from OEM. Current revision, availability and supplied scope are confirmed in the written quotation.
Basler Electric AVC63-12 and AVC125-10 Official Instruction Manual, Link

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

AVC63-12 identifies 63 Vdc at 12 Adc maximum continuous output. Style A selects nominal 100/120 Vac sensing and style 1 selects 50/60 Hz operation.

Confirm 90 to 153 Vac power input, 90 to 139 Vac sensing, field resistance, phase configuration and the exact shunt or PMG excitation source before wiring.

The regulator supports single- or three-phase sensing and 1 or 5 A CT secondary input for droop or line-drop compensation. CT polarity and sensing-transformer grounding must follow the approved generator design.

Record underfrequency, droop, voltage and stability settings before removal. Do not alter the factory-calibration control unless the manufacturer procedure specifically requires recalibration.

Match every numbered terminal, F1 and F2 field polarity, phase arrangement, grounding and protective device. Confirm the generator is stopped and isolated before any field-flashing or wiring work.

Commission with the approved generator procedure: verify voltage buildup, sensing, field output, underfrequency response, stability and regulation under controlled no-load and load conditions.

Technical notes

Installation and testing must be completed by qualified generator-excitation personnel. Preserve every terminal, jumper and adjustment setting, verify the exact A1 sensing style and field circuit, and follow the Basler and generator-manufacturer commissioning procedures.

Style Identity & Excitation-System Match

Match AVC63-12A1 in full. Verify 63 Vdc at 12 Adc output, A sensing, 50/60 Hz style, excitation source, generator field resistance, CT secondary and all accessory connections before replacement.

Terminal Record & Operational Test

Record terminals, jumpers and control positions before removal. After installation, perform insulation and wiring checks, then verify voltage buildup, frequency compensation, stability, droop or line-drop behavior and generator voltage regulation under controlled conditions.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No verified exact-model warehouse dimensions were found; packed dimensions are recorded after protective packing.
  • Packed shipping weight
    Confirmed after final packing
    No verified exact-model warehouse weight was found; final gross shipping weight is recorded after protective packing.
  • HS / customs code
    Confirmed for the destination
    Final classification depends on the declared item and destination.
  • Country of origin
    Confirmed from supplied item
    Verified from the product nameplate or traceable documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available documentation is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about AVC63-12A1

  • How is the exact AVC63-12A1 item identified?

    Match AVC63-12A1 on the supplied label. The AVC63-12 model, sensing code A and frequency code 1 must all agree with the generator documentation.
  • Which system and application details must be checked?

    Confirm the brushless generator excitation source, field resistance, sensing-transformer arrangement, CT secondary, phase configuration, accessories and complete terminal design.
  • Which published ratings or interfaces must be matched?

    The A1 style identifies 100/120 Vac nominal sensing at 50/60 Hz. The regulator provides 63 Vdc at 12 Adc continuous output and uses 90 to 153 Vac power input.
  • What should be recorded before removal?

    Photograph the label and every terminal, then record jumpers, voltage, stability, underfrequency and droop settings, CT polarity, sensing voltages and field resistance.
  • What must be checked during installation?

    Isolate the generator and excitation system, reproduce terminal and jumper positions exactly, verify F1/F2 polarity and grounding, and complete pre-energization checks.
  • What should be tested after installation?

    Verify voltage buildup, no-load voltage adjustment, frequency compensation, stability, droop or line-drop operation, field output and regulation during controlled load testing.
  • What should be inspected when the item arrives?

    Inspect the complete label, terminal strips, heat sinks, capacitors, adjustment controls, jumpers, mounting base, supplied accessories and packaging before installation.
  • What information and accessory scope are required for a quotation?

    Provide AVC63-12A1, quantity, required condition, destination, clear label photos, generator and excitation details, and any required accessories, certificates or inspection records.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Active / Available from OEM

    Moore Automated supplies BASLER ELECTRIC AVC63-12A1 Automatic Voltage Regulator units subject to confirmed availability and condition. Every supplied item is inspected before shipment to support stable operation and reduce unplanned downtime.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

AVC63-12A1
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.