Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Wednesday, October 28
Fast Shipping Available
Reverse-mount eddy-current displacement probe

PR6423/03R-012-ZD

Product Information:

PR6423/03R-012-ZD is an Emerson PR6423 eddy-current probe execution for non-contact shaft displacement measurements in a documented reverse-mount installation. Its full suffix controls the mechanical, cable and connection arrangement, and the probe must be used only with the matched converter chain and installed geometry defined for the machine.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      PR6423/03R-012-ZD is an Emerson PR6423 eddy-current probe execution for non-contact shaft displacement measurements in a documented reverse-mount installation. Its full suffix controls the mechanical, cable and connection arrangement, and the probe must be used only with the matched converter chain and installed geometry defined for the machine. The PR6423/03R-012-ZD supports the documented reverse-mount eddy-current displacement probe duty within the Emerson Process Automation architecture. Correct selection depends on the complete order code, hardware revision, connected assemblies and approved control-system configuration. Before installation, compare the original label and wiring or connector allocation; after installation, review diagnostics and function-test every affected path.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Industry applications depend on the documented function and verified receiving system.

      Power Generation

      Applies the PR6423/03R-012-ZD reverse-mount eddy-current displacement probe in verified power generation automation systems when the installed Emerson Process Automation configuration and exact hardware execution match.

      Chemical Processing

      Applies the PR6423/03R-012-ZD reverse-mount eddy-current displacement probe in verified chemical processing automation systems when the installed Emerson Process Automation configuration and exact hardware execution match.

      Pulp & Paper

      Applies the PR6423/03R-012-ZD reverse-mount eddy-current displacement probe in verified pulp & paper automation systems when the installed Emerson Process Automation configuration and exact hardware execution match.

      Oil & Gas

      Applies the PR6423/03R-012-ZD reverse-mount eddy-current displacement probe in verified oil & gas automation systems when the installed Emerson Process Automation configuration and exact hardware execution match.
Technical specifications for

PR6423/03R-012-ZD

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Epro
  • Product Category:
    Probes
  • Measurement Range:
    2 mm / 80 mils linear range
  • Initial Air Gap:
    0.5 mm / 20 mils
  • Scale Factor:
    8 V/mm ±5% from 0 to 45°C
  • Case Thread:
    M10 × 1 family execution
  • Mounting Style:
    Reverse mount
  • Cable Protection:
    Armored-cable reverse-mount execution
  • Protection Class:
    IP66
  • Target Material:
    42CrMo4 / AISI 4140 standard target
  • Special Execution:
    ZD suffix; preserve complete order code
  • Product Type:
    Reverse-mount eddy-current displacement probe
  • Series:
    Epro Sensors and Measurement Chains
  • Hardware Format:
    Industrial control module
  • Platform Architecture:
    Industrial process-automation architecture
  • Installation Context:
    Industrial control-system hardware
  • Stock Availability:
    4
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

PR 6423/03R-012-ZD PR6423 reverse-mount 8 mm probe PR642303R012ZD

Information

Overview Manuals Identity Evidence Order Controls Technical Boundary

Features:

  • Measurement Range: Supports the documented 2 mm / 80 mils linear range specification in the approved Emerson Process Automation configuration.
  • Initial Air Gap: The documented reverse-mount eddy-current displacement probe specification is 0.5 mm / 20 mils; verify it against the supplied label before installation.
  • Scale Factor: The documented reverse-mount eddy-current displacement probe specification is 8 V/mm ±5% from 0 to 45°C; verify it against the supplied label before installation.
The PR6423/03R-012-ZD Emerson reverse-mount eddy-current displacement probe performs its documented automation, interface, control or monitoring duty within the Emerson Process Automation platform. Its correct operation depends on the relationship between the installed hardware, connected field equipment and approved system configuration. Complete model identification reduces the risk of connector, channel and revision mismatches during maintenance.

Before installing PR6423/03R-012-ZD, compare the full product label, installed position, terminal or connector arrangement, paired assemblies, firmware or logic requirements and available project records. After replacement, review diagnostics and function-test every affected control, protection, communication or field-signal path before returning the equipment to service.

The PR6423/03R-012-ZD Emerson Reverse-mount eddy-current displacement probe is identified as Active / Available from OEM. Current availability, revision and supplied scope are confirmed in the written quotation.
Emerson PR6423/03R-012-ZD documentation and reference links.Important Notice: The linked information must identify the listed model or its documented family. Confirm the complete order code, hardware revision and installed-system requirements before replacement.

Verify that the supplied item is marked PR6423/03R-012-ZD and that its reverse-mount eddy-current displacement probe form, connectors and revision agree with the approved Emerson Process Automation receiving record.

For PR6423/03R-012-ZD, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.

Apply only parameters supported by the exact PR6423/03R-012-ZD record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.

Technical notes

PR6423/03R-012-ZD must be selected as the exact reverse-mount eddy-current displacement probe identified by its complete hardware marking. Preserve the Emerson Process Automation receiving position, connected hardware and configuration record during replacement.

Technical Scope

PR6423/03R-012-ZD technical scope: Measurement Range: 2 mm / 80 mils linear range; Initial Air Gap: 0.5 mm / 20 mils; Scale Factor: 8 V/mm ±5% from 0 to 45°C; Case Thread: M10 × 1 family execution; Mounting Style: Reverse mount.

Use these values only for the listed hardware execution and verify the supplied label before installation.

Installation Review

Match PR6423/03R-012-ZD to the approved Emerson Process Automation receiving position, connector or terminal arrangement and configuration record.

After power restoration, review diagnostics and test the affected reverse-mount eddy-current displacement probe path.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    Measure the verified item, included accessories and protective packaging after final packing.
  • Packed shipping weight
    Confirmed after final packing
    Weigh the verified item, included accessories and protective packaging after final packing.
  • HS / customs code
    8538900000 (indicative reference)
    Indicative reference for an industrial control-system board or module; the destination declarant confirms final classification from the supplied item and shipment evidence.
  • Country of origin
    Confirm from supplied item
    Use the physical origin marking and traceable shipment or manufacturer documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch date, supplied quantity and handling details are stated in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about PR6423/03R-012-ZD

  • How is the exact PR6423/03R-012-ZD execution confirmed?

    Compare the complete PR6423/03R-012-ZD marking, hardware revision, connectors and installed position with the approved equipment record.
  • Which platform must PR6423/03R-012-ZD match?

    The supplied reverse-mount eddy-current displacement probe must match the documented Emerson Process Automation hardware and project configuration.
  • Which function is assigned to PR6423/03R-012-ZD?

    Use PR6423/03R-012-ZD only for its documented reverse-mount eddy-current displacement probe function and verified receiving-system role.
  • Which measurement range applies to PR6423/03R-012-ZD?

    The retained product record states Measurement Range: 2 mm / 80 mils linear range; confirm the supplied execution has the same value.
  • Which configuration records are required for PR6423/03R-012-ZD?

    Retain installed position, channel mapping, firmware or logic dependencies, connected assemblies and the approved project record.
  • How should PR6423/03R-012-ZD be tested after installation?

    Review diagnostics and function-test every affected control, I/O, protection or communication path before release.
  • Can another revision replace PR6423/03R-012-ZD directly?

    Do not assume interchangeability; compare the full code, hardware revision, system version and receiving documentation.
  • What should accompany an enquiry for PR6423/03R-012-ZD?

    Provide clear label photographs, installed position, required condition, quantity and the applicable system or cabinet reference.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Active / Available from OEM

    Moore Automated supplies genuine-quality Emerson PR6423/03R-012-ZD Reverse-mount eddy-current displacement probe units for industrial control maintenance. Every supplied item is inspected before shipment; the exact hardware identity, condition and included accessories are confirmed in the written quotation.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

PR6423/03R-012-ZD
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.