8mm Eddy Current Sensor

PR6423/13R-040 CON021

Product Information:

PR6423/13R-040 CON021 is a Emerson 8mm eddy current sensor engineered for the Emerson EPRO eddy-current measurement system. It performs the documented 8mm eddy current sensor function within the Emerson EPRO PR 642x hardware architecture, so the complete order code, hardware execution and receiving position must be retained during selection.

Product-level and manufacturer-family information records linear measurement range: 2 mm (80 mils); initial air gap: 0.5 mm (20 mils); deviation from best fit straight line (dsl): ± 0.025 mm (± 1 mil); minimum shaft diameter: 25 mm (0.79”). Before replacement, compare the installed label, rack or carrier, terminal or connector arrangement, power and signal requirements and approved configuration; after installation, verify diagnostics and every affected control, communication, safety or monitoring path before returning the equipment to service.

  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      PR6423/13R-040 CON021 is a Emerson 8mm eddy current sensor engineered for the Emerson EPRO eddy-current measurement system. It performs the documented 8mm eddy current sensor function within the Emerson EPRO PR 642x hardware architecture, so the complete order code, hardware execution and receiving position must be retained during selection. Product-level and manufacturer-family information records linear measurement range: 2 mm (80 mils); initial air gap: 0.5 mm (20 mils); deviation from best fit straight line (dsl): ± 0.025 mm (± 1 mil); minimum shaft diameter: 25 mm (0.79”). Before replacement, compare the installed label, rack or carrier, terminal or connector arrangement, power and signal requirements and approved configuration; after installation, verify diagnostics and every affected control, communication, safety or monitoring path before returning the equipment to service.

      Selection basis

      Confirm the complete PR6423/13R-040 CON021 identity, receiving hardware, connectors or terminals and approved configuration before replacement.
    • APPLICATIONS

      Where it may be used

      Typical industries for this documented 8mm eddy current sensor execution.

      Water Treatment

      Uses the documented sensing function in treatment and utility skids.

      Material Handling

      Detects qualified targets on conveyor and transfer equipment.

      Position Sensing

      Applies the documented sensing range in industrial position duties.

      OEM Machinery

      Restores the exact sensor execution in approved machine designs.
Technical specifications for

PR6423/13R-040 CON021

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Epro
  • Product Category:
    Sensor
  • Linear Measurement Range:
    2 mm (80 mils)
  • Initial Air Gap:
    0.5 mm (20 mils)
  • Deviation from best fit straight line (DSL):
    ± 0.025 mm (± 1 mil)
  • Minimum Shaft Diameter:
    25 mm (0.79”)
  • Protection Class:
    IP66, IEC 60529
  • Operating Temperature Range:
    -35 to +180°C (-31 to 356°F)
  • Product Type:
    Eddy Current Sensor
  • Stock Availability:
    5
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

PR642313R040CON021 PR6423 13R 040 CON021 PR 6423/13 R-040 CON 021 Emerson PR6423/13R-040 CON021 PR6423/13R-040-CON021 PR6423/13R-040 CON021

Information

Overview Manuals Sensor Setup System Match Install Checks

Features:

  • 8mm Eddy Current Sensor for the documented Emerson EPRO eddy-current measurement system.
  • Linear Measurement Range: 2 mm (80 mils).
  • Initial Air Gap: 0.5 mm (20 mils).
PR6423/13R-040 CON021 is a Emerson 8mm eddy current sensor engineered for the Emerson EPRO eddy-current measurement system. It performs the documented 8mm eddy current sensor function within the Emerson EPRO PR 642x hardware architecture, so the complete order code, hardware execution and receiving position must be retained during selection.

Product-level and manufacturer-family information records linear measurement range: 2 mm (80 mils); initial air gap: 0.5 mm (20 mils); deviation from best fit straight line (dsl): ± 0.025 mm (± 1 mil); minimum shaft diameter: 25 mm (0.79”). Before replacement, compare the installed label, rack or carrier, terminal or connector arrangement, power and signal requirements and approved configuration; after installation, verify diagnostics and every affected control, communication, safety or monitoring path before returning the equipment to service.

The PR6423/13R-040 CON021 8mm Eddy Current Sensor is supplied only after the exact hardware identity, condition and current OEM lifecycle status have been confirmed.
Emerson PR6423/13R-040 CON021 8mm Eddy Current Sensor manuals and technical resources.Important Notice: The linked PDF documents the listed model or its identified product family. Confirm the full order code, hardware revision and installed-system requirements before replacement. Accessories, cables, software and certificates are included only when stated in the quotation. All prices are shown in USD.

PR6423/13R-040 CON021 is a Emerson 8mm eddy current sensor engineered for the Emerson EPRO eddy-current measurement system. It performs the documented 8mm eddy current sensor function within the Emerson EPRO PR 642x hardware architecture, so the complete order code, hardware execution and receiving position must be retained during selection.

The listed parameters are limited to the documented model or product-family evidence. Compare the complete label, receiving hardware, terminal map and connected equipment rather than transferring ratings from a nearby code.

PR6423/13R-040 CON021 must remain matched to the documented Emerson EPRO eddy-current measurement system installation. Confirm hardware generation, slot or carrier, connector or terminal arrangement, software or configuration dependencies and system drawings before approval.

Photograph labels and connections before removal and preserve the original position, keying, addressing and channel allocation.

Isolate the equipment using the approved procedure, verify stored energy is removed and inspect the receiving hardware before fitting PR6423/13R-040 CON021.

After installation, restore power in the documented sequence, review diagnostics and test every affected signal, relay, network, control, safety or monitoring function against the commissioning record.

Technical notes

PR6423/13R-040 CON021 must be selected and serviced as the exact 8mm eddy current sensor identified by its complete hardware marking. Preserve the receiving rack or carrier, connector and terminal assignment, connected equipment, configuration record and any protection or diagnostic dependencies; after installation, verify seating, power, status indications and each affected control, I/O, communication or monitoring path before the equipment is returned to operation.

Identity Check

Verify that the supplied item is marked PR6423/13R-040 CON021 and that its hardware form, connectors, terminal blocks, faceplate and printed revision agree with the approved receiving-system record.

Use photographs of both sides and the installed position to resolve ambiguity before shipment or installation.

Quote Details

For an accurate PR6423/13R-040 CON021 quotation, provide quantity, required condition, installed system and slot, connected terminal or cable assemblies and any revision restrictions.

State whether testing, certificates, matched accessories or a scheduled outage date must be included in the written offer.

Customs & shipping dimensions / weight

  • Product dimensions
    Confirm from supplied item
    No exact-model record is present in the supplied dimensions-and-weight sheet; measure the supplied item before dispatch.
  • Product weight
    Confirm from supplied item
    No exact-model record is present in the supplied dimensions-and-weight sheet; weigh the supplied item before dispatch.
  • HS / customs code
    9031809090
    Indicative China HS classification for position, proximity or vibration sensor; final classification is confirmed by the customs declarant.
  • Country of origin
    Confirm from supplied item
    Origin is verified against the supplied item and applicable manufacturer documentation.
  • Ships from
    Xiamen, Fujian, China
    The dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Invoice, packing-list and origin-document requirements are agreed with the order.
PRODUCT & ORDER FAQS

Questions buyers ask about PR6423/13R-040 CON021

  • How is the exact PR6423/13R-040 CON021 execution identified?

    Use the complete PR6423/13R-040 CON021 marking, including every suffix and companion code, and compare it with the installed hardware record; a shortened base model does not confirm interchangeability.
  • Which function does PR6423/13R-040 CON021 perform?

    PR6423/13R-040 CON021 performs the documented 8mm eddy current sensor role in the Emerson EPRO eddy-current measurement system.
  • Which linear measurement range applies to PR6423/13R-040 CON021?

    The documented linear measurement range is 2 mm (80 mils); confirm it against the exact supplied execution.
  • Which initial air gap should be checked for PR6423/13R-040 CON021?

    Check 0.5 mm (20 mils) for initial air gap and do not import a rating from a nearby part number.
  • Which system must PR6423/13R-040 CON021 match?

    It must match the Emerson EPRO eddy-current measurement system, including the receiving rack or carrier generation, system configuration and connected equipment.
  • Which wiring or connector checks apply to PR6423/13R-040 CON021?

    Compare terminal numbering, connector keying, field supply, grounding, shielding and any paired termination or cable assembly with the approved drawings before removal.
  • How should PR6423/13R-040 CON021 be commissioned after installation?

    Verify seating and wiring first, restore power in the approved sequence, review diagnostics and test every affected channel, network, control, safety or monitoring path.
  • Can another revision replace PR6423/13R-040 CON021 directly?

    Do not assume direct interchangeability. Compare the complete PR6423/13R-040 CON021 code, deviation from best fit straight line (dsl) (± 0.025 mm (± 1 mil)), hardware revision, firmware dependencies and receiving-system documentation.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Lifecycle status is confirmed against current manufacturer records at quotation. The exact PR6423/13R-040 CON021 identity, hardware revision and included assemblies are checked against the supplied item.

    Any replacement or migration option is proposed only after the receiving Emerson EPRO eddy-current measurement system, connectors, configuration dependencies and commissioning requirements have been reviewed.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

PR6423/13R-040 CON021
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.