Epro PR6426/010-030 CON021/916-160
Epro PR6426/010-030 CON021/916-160
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Tuesday, October 27
Fast Shipping Available
32mm Eddy Current Sensor

PR6426/010-030 CON021/916-160

Product Information:

PR6426/010-030 CON021/916-160 is a Emerson 32mm eddy current sensor used within the Emerson DeltaV distributed control system. It provides the specified 32mm eddy current sensor function while retaining the complete order code, hardware execution and receiving-system compatibility during replacement. Its documented sleeve thread is NO THREAD.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      PR6426/010-030 CON021/916-160 is a Emerson 32mm eddy current sensor used within the Emerson DeltaV distributed control system. It provides the specified 32mm eddy current sensor function while retaining the complete order code, hardware execution and receiving-system compatibility during replacement. Its documented sleeve thread is NO THREAD. The PR6426/010-030 CON021/916-160 supports the documented 32mm eddy current sensor duty within the Epro Sensors and Measurement Chains architecture. Correct selection depends on the complete order code, hardware revision, connected assemblies and approved control-system configuration. Before installation, compare the original label and wiring or connector allocation; after installation, review diagnostics and function-test every affected path.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Industry applications depend on the documented function and verified receiving system.

      Chemical Processing

      Applies the PR6426/010-030 CON021/916-160 32mm eddy current sensor in verified chemical processing automation systems when the installed Epro Sensors and Measurement Chains configuration and exact hardware execution match.

      Food & Beverage

      Applies the PR6426/010-030 CON021/916-160 32mm eddy current sensor in verified food & beverage automation systems when the installed Epro Sensors and Measurement Chains configuration and exact hardware execution match.

      Pulp & Paper

      Applies the PR6426/010-030 CON021/916-160 32mm eddy current sensor in verified pulp & paper automation systems when the installed Epro Sensors and Measurement Chains configuration and exact hardware execution match.

      Pharmaceutical Manufacturing

      Applies the PR6426/010-030 CON021/916-160 32mm eddy current sensor in verified pharmaceutical manufacturing automation systems when the installed Epro Sensors and Measurement Chains configuration and exact hardware execution match.
Technical specifications for

PR6426/010-030 CON021/916-160

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Epro
  • Product Category:
    Sensor
  • Sleeve Thread:
    NO THREAD
  • Armored Cable:
    WITH Armored Cable
  • Total Sensor Length:
    Mounting Plate 80 mm x 40 mm
  • Adaptor Plug:
    WITH Adaptor Plug
  • Total Cable Length:
    8 m
  • Cable End:
    LEMO
  • Sensitivity:
    2 V/mm (50.8 mV/mil) ≤ ±1.5% max
  • Long Term Drift:
    < 0.3%
  • Series:
    Epro Sensors and Measurement Chains
  • Product Type:
    32mm Eddy Current Sensor
  • Hardware Format:
    Industrial control module
  • Platform Architecture:
    Distributed process-control architecture
  • Installation Context:
    Industrial control-system hardware
  • Compatibility Scope:
    Epro Sensors and Measurement Chains installed control system
  • Stock Availability:
    3
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

PR6426010030CON021916160 PR6426 010 030 CON021 916 160 Emerson PR6426/010-030 CON021/916-160 PR6426/010-030 CON021/916-160 32mm Eddy Current Sensor Emerson DeltaV PR6426/010-030 CON021/916-160 DeltaV PR6426/010-030 CON021/916-160 PR6426/010-030 CON021/916-160 controller, I/O or carrier module PR6426/010-030

Information

Overview Manuals Identity Evidence Order Controls Technical Boundary

Features:

  • Total Sensor Length: The documented 32mm eddy current sensor specification is Mounting Plate 80 mm x 40 mm; verify it against the supplied label before installation.
  • Total Cable Length: The documented 32mm eddy current sensor specification is 8 m; verify it against the supplied label before installation.
  • Sensitivity: The documented 32mm eddy current sensor specification is 2 V/mm (50.8 mV/mil) ≤ ±1.5% max; verify it against the supplied label before installation.
The PR6426/010-030 CON021/916-160 Emerson 32mm eddy current sensor performs its documented automation, interface, control or monitoring duty within the DeltaV platform. Its correct operation depends on the relationship between the installed hardware, connected field equipment and approved system configuration. Complete model identification reduces the risk of connector, channel and revision mismatches during maintenance.

Before installing PR6426/010-030 CON021/916-160, compare the full product label, installed position, terminal or connector arrangement, paired assemblies, firmware or logic requirements and available project records. After replacement, review diagnostics and function-test every affected control, protection, communication or field-signal path before returning the equipment to service.

The PR6426/010-030 CON021/916-160 Emerson 32mm Eddy Current Sensor is identified as Active / Available from OEM. Current availability, revision and supplied scope are confirmed in the written quotation.
Emerson PR6426/010-030 CON021/916-160 documentation and reference links.Important Notice: The linked information must identify the listed model or its documented family. Confirm the complete order code, hardware revision and installed-system requirements before replacement.

Verify that the supplied item is marked PR6426/010-030 CON021/916-160 and that its 32mm eddy current sensor form, connectors and revision agree with the approved DeltaV receiving record.

For PR6426/010-030 CON021/916-160, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.

Apply only parameters supported by the exact PR6426/010-030 CON021/916-160 record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.

Technical notes

PR6426/010-030 CON021/916-160 must be selected as the exact 32mm eddy current sensor identified by its complete hardware marking. Preserve the DeltaV receiving position, connected hardware and configuration record during replacement.

Technical Scope

PR6426/010-030 CON021/916-160 technical scope: Sleeve Thread: NO THREAD; Armored Cable: WITH Armored Cable; Total Sensor Length: Mounting Plate 80 mm x 40 mm; Adaptor Plug: WITH Adaptor Plug; Total Cable Length: 8 m.

Use these values only for the listed hardware execution and verify the supplied label before installation.

Installation Review

Match PR6426/010-030 CON021/916-160 to the approved DeltaV receiving position, connector or terminal arrangement and configuration record.

After power restoration, review diagnostics and test the affected 32mm eddy current sensor path.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    Measure the verified item, included accessories and protective packaging after final packing.
  • Packed shipping weight
    Confirmed after final packing
    Weigh the verified item, included accessories and protective packaging after final packing.
  • HS / customs code
    8538900000 (indicative reference)
    Indicative reference for an industrial control-system board or module; the destination declarant confirms final classification from the supplied item and shipment evidence.
  • Country of origin
    Confirm from supplied item
    Use the physical origin marking and traceable shipment or manufacturer documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch date, supplied quantity and handling details are stated in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about PR6426/010-030 CON021/916-160

  • How is the exact PR6426/010-030 CON021/916-160 execution confirmed?

    Compare the complete PR6426/010-030 CON021/916-160 marking, hardware revision, connectors and installed position with the approved equipment record.
  • Which platform must PR6426/010-030 CON021/916-160 match?

    The supplied 32mm eddy current sensor must match the documented DeltaV hardware and project configuration.
  • Which function is assigned to PR6426/010-030 CON021/916-160?

    Use PR6426/010-030 CON021/916-160 only for its documented 32mm eddy current sensor function and verified receiving-system role.
  • Which sleeve thread applies to PR6426/010-030 CON021/916-160?

    The retained product record states Sleeve Thread: NO THREAD; confirm the supplied execution has the same value.
  • Which configuration records are required for PR6426/010-030 CON021/916-160?

    Retain installed position, channel mapping, firmware or logic dependencies, connected assemblies and the approved project record.
  • How should PR6426/010-030 CON021/916-160 be tested after installation?

    Review diagnostics and function-test every affected control, I/O, protection or communication path before release.
  • Can another revision replace PR6426/010-030 CON021/916-160 directly?

    Do not assume interchangeability; compare the full code, hardware revision, system version and receiving documentation.
  • What should accompany an enquiry for PR6426/010-030 CON021/916-160?

    Provide clear label photographs, installed position, required condition, quantity and the applicable system or cabinet reference.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Active / Available from OEM

    Moore Automated supplies genuine-quality Emerson PR6426/010-030 CON021/916-160 32mm Eddy Current Sensor units for industrial control maintenance. Every supplied item is inspected before shipment; the exact hardware identity, condition and included accessories are confirmed in the written quotation.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

PR6426/010-030 CON021/916-160
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.