Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
IS220YDOAS1AJ provides twelve discrete output channels, dual IONet Ethernet ports and front-panel channel indication. The matching label specifies 28 Vdc module power and 30 Vdc, 5 A dc contact output.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
IS220YDOAS1AJ is used for discrete output duties in qualified GE Mark VIeS turbine-control projects, including relay-driven actuators, alarms and auxiliary equipment. The actual field load and interposing relay arrangement must match the installed TRLYS terminal board and project drawings.
Typical installations include power-generation turbine packages, turbine-driven compressor trains and industrial utility systems. Industry context does not establish interchangeability; approve the module by its complete suffix and system documentation.
The matching IS220YDOAS1AJ label states 28 Vdc, 0.71 A dc module power, 30 Vdc, 5 A dc contact output and an ambient range of -30 to +65 degrees C. The faceplate includes twelve numbered output indicators, ENET1 and ENET2 IONet ports and an infrared service port.
GE family documentation lists IS200TRLYS1F, IS200TRLYS2F, IS400TRLYS1F and IS400TRLYS2F as associated relay terminal-board executions. Confirm the exact installed board revision before replacement.
Before removal, photograph the complete IS220YDOAS1AJ label and record the installed position, terminal-board part number, channel allocation, Ethernet connections and active diagnostics. Preserve the controller and I/O configuration in accordance with the site procedure.
After installation, confirm module power, both IONet links and controller diagnostics, then prove every affected output in a safe test state. Do not assume that another YDOA or PDOA suffix is a direct substitute.
Verify the complete IS220YDOAS1AJ code, AJ suffix, IS220YDOAS1A family marking, ART or hardware revision and yellow DISCRETE OUT faceplate. Compare connector layout and the paired TRLYS terminal board with the installed project record. If any marking is unclear, provide clear photographs of every label before approval.
Provide the complete IS220YDOAS1AJ model, quantity, required condition, label photographs, installed terminal-board part number, receiving equipment, delivery country and required delivery date. Also state any certificate, inspection-photo or document requirements so Moore Automated can match the exact item and prepare the quotation.
Active / Available from OEM
GE conformity documentation includes the IS220YDOAS1A discrete output family and its associated relay terminal boards. Moore Automated confirms the exact AJ revision, condition and supplied scope in the written quotation.