General Electric ACC-5595-208
General Electric ACC-5595-208
General Electric ACC-5595-208
General Electric ACC-5595-208
General Electric ACC-5595-208
General Electric ACC-5595-208
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Thursday, November 5
Fast Shipping Available
VMIACC-5595 2 Gb/s Eight-Port Multimode Reflective Memory Hub

ACC-5595-208

Spare Part Number

PNVMIACC5595208

Product Information:

General Electric ACC-5595-208 is the VMIACC-5595 managed reflective-memory hub in a rack-mount or desktop enclosure. The -208 execution contains eight multimode pluggable optical transceivers, no single-mode transceivers, a 10Base-T management port, an RS-232 port and an internal universal power supply for documented VMIxxx-5565 networks.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      General Electric ACC-5595-208 is the VMIACC-5595 managed reflective-memory hub in a rack-mount or desktop enclosure. The -208 execution contains eight multimode pluggable optical transceivers, no single-mode transceivers, a 10Base-T management port, an RS-232 port and an internal universal power supply for documented VMIxxx-5565 networks.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Applications describe the product family and are not an automatic compatibility or functional-safety approval.

      Power Generation

      Links qualified reflective-memory nodes used in deterministic turbine, generator and plant-control networks.

      Aerospace & Defense

      Supports approved real-time simulation, hardware-in-the-loop and test-range data networks.

      Industrial Test Systems

      Connects documented high-speed data-acquisition and control nodes in laboratory and production test cells.

      Transportation Systems

      Supports engineered real-time control and simulation networks used in rail and transport infrastructure projects.
Technical specifications for

ACC-5595-208

0 TECHNICAL PARAMETERS
  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Spare Part Number:
    VMIACC5595208
  • Product Family:
    VMIACC-5595
  • Device Type:
    Managed reflective-memory hub
  • Reflective-Memory Data Rate:
    2 Gb/s
  • Enclosure:
    19-inch 1U rack mount or desktop
  • Optical Ports:
    8
  • Multimode Transceivers:
    8
  • Single-Mode Transceivers:
    0
  • Optical Connector:
    LC on installed SFP transceivers
  • Compatible Network Family:
    VMIxxx-5565 Reflective Memory
  • Network Topology:
    Star; automatic node bypass
  • Management Interfaces:
    10Base-T Ethernet and RS-232
  • Port Grouping:
    1 x 8 or 2 x 4
  • Cascade Capacity:
    Up to 256 network nodes
  • Maximum Multimode Cable Length:
    300 m with documented 50 µm fiber
  • Power Supply:
    Internal universal AC power supply
  • Installation Guide:
    522-805595-000
  • Stock Availability:
    2
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

VMIACC-5595-208 VMIACC5595208 350-805595-208 350-805595-208L

Information

Overview Manuals Reflective Memory Architecture Optical Port Configuration Network Integration

Features:

  • Eight installed multimode SFP transceivers with no single-mode transceivers.
  • Managed 2 Gb/s reflective-memory star network with automatic bypass and signal regeneration.
  • Rack-mount or desktop enclosure with Ethernet and RS-232 management interfaces.

ACC-5595-208 is the eight-multimode-port execution of the VMIACC-5595 hub family. The full -208 suffix controls the installed optical transceiver mix and must not be confused with the -280 single-mode execution.

Before replacement, record the full part number, installed transceivers, fiber type and polarity, port map, 1x8 or 2x4 grouping, detect and bypass modes, IP settings, serial settings, rack hardware and network-node configuration. After installation, verify every optical path and deterministic data route.

The ACC-5595-208 General Electric eight-port multimode reflective-memory hub is listed as Active / Available from OEM. Current revision, availability and supplied scope are confirmed in the written quotation.
General Electric ACC-5595-208 documentation and reference links.Important Notice: Confirm the complete order identity, hardware execution, receiving-system configuration and required document revision before replacement.

The managed hub supports the 2 Gb/s VMIxxx-5565 reflective-memory network and can operate as one eight-port group or two four-port groups.

Suffix -208 identifies eight multimode optical transceivers. Match the LC fiber type, polarity and installed SFP execution.

Restore the approved port grouping, IP and serial settings, then test signal detection, automatic bypass and every connected node.

Technical notes

The GE Automation & Control catalog identifies ACC-5595-208 as a rack-mount or desktop reflective-memory hub with universal power, one Ethernet port, one RS-232 port and eight multimode pluggable transceivers. GE publication 522-805595-000 documents the VMIACC-5595 managed 2 Gb/s hub architecture. Confirm the complete ACC-5595-208 or VMIACC-5595-208 identity, eight multimode SFP transceivers, LC fiber type and polarity, 2 Gb/s VMIxxx-5565 network, port grouping, management settings, enclosure and power input. Do not substitute the -280 single-mode execution. Reproduce the approved port map and configuration, verify power and grounding, then confirm Ethernet or RS-232 management, every optical link, signal-detect and bypass behavior, port grouping, node communication and system-level recovery before return to service.

Node and Memory-Mapping Record

Document the reflective-memory node IDs, address ranges, interrupt assignments and any segmentation or timeout settings used by the installed network. Retain the approved map for post-service comparison.

Optical Diagnostic Baseline

Capture transceiver identification, receive or transmit diagnostic values, link-error counters and bypass events for every populated optical port. Compare the restored links with this baseline before releasing the network.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    Exact packed dimensions for ACC-5595-208 are stated in the written quotation.
  • Packed shipping weight
    Confirmed after final packing
    Exact packed weight for ACC-5595-208 is stated in the written quotation.
  • HS / customs code
    Confirmed before shipment
    Final classification depends on the supplied configuration, destination and invoice documents.
  • Country of origin
    Confirmed from the item label or certificate
    Exact origin is stated in the written quotation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about ACC-5595-208

  • Which optical execution is identified by ACC-5595-208?

    The -208 execution has eight multimode pluggable transceivers and no single-mode transceivers.
  • Which reflective-memory products are compatible with ACC-5595-208?

    The VMIACC-5595 hub is designed for documented VMIxxx-5565 Reflective Memory products; verify each node and firmware before installation.
  • Which management interfaces does ACC-5595-208 provide?

    The hub provides a 10Base-T Ethernet TCP/IP management port and an RS-232 local management port.
  • How can the eight optical ports be grouped?

    The front-panel grouping selection supports one group of eight ports or two independent groups of four ports.
  • What must be recorded before removing ACC-5595-208?

    Record the full suffix, transceiver types, fiber polarity, port map, grouping, detect and bypass modes, IP and serial settings, rack hardware and network-node configuration.
  • Can ACC-5595-280 replace ACC-5595-208 automatically?

    No. The -280 execution uses single-mode transceivers, while -208 uses multimode transceivers; the complete fiber plant and network design must match.
  • How should ACC-5595-208 be commissioned?

    Verify power and grounding, restore the approved configuration, then test every optical link, bypass path, port group and connected reflective-memory node.
  • Which details are needed to quote ACC-5595-208?

    Provide quantity, complete label photographs, installed SFP and rack details, required condition, destination and delivery date.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Active / Available from OEM

    General Electric ACC-5595-208 is the VMIACC-5595 managed reflective-memory hub in a rack-mount or desktop enclosure. The -208 execution contains eight multimode pluggable optical transceivers, no single-mode transceivers, a 10Base-T management port, an RS-232 port and an internal universal power supply for documented VMIxxx-5565 networks. Moore Automated confirms the offered unit's exact marking, condition, availability, included accessories and supply scope in the written quotation.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

ACC-5595-208
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.