8C-PAINA1 51454470-175 is a coated Honeywell Series 8 single-ended analog-input module without HART. Honeywell specifies sixteen 4-20 mA channels, 16-bit conversion, a 50 ms input scan, 24 VDC operation and optional redundant IOTA architecture. Confirm the complete suffix, IOTA, field-power arrangement and controller configuration before replacement.
8C-PAINA1 is the coated Series 8 high-level analog-input IOM without HART. Its sixteen single-ended channels accept 4-20 mA current from 2-wire or self-powered transmitters through the documented 250-ohm input path. Honeywell specifies 16-bit conversion, a 50 ms scan, 24 VDC operation and 105 mA module current. The absence of HART is a functional distinction and must not be replaced by assuming compatibility from the Series 8 family name alone.
The IOM is documented with 8C-TAIXA1 for a nominal 6-inch nonredundant arrangement or 8C-TAIXB1 for a nominal 12-inch redundant arrangement. Preserve the installed field-power selection, commons, channel numbering, grounding and controller database. Verify the receiving hardware and the approved redundancy design before moving any loop conductors. Honeywell's nominal IOTA lengths describe termination assemblies, not the packed module dimensions; the source does not establish exact shipping size or weight.
Use the module only for the documented single-ended 4-20 mA current-input path. Verify 2-wire or self-powered transmitter wiring, polarity, loop supply, channel assignment and controller scaling. This execution does not provide HART communication, so device diagnostics cannot be assumed from the analog signal alone.
Match the installed termination architecture before moving conductors. Use 8C-TAIXA1 for the documented nonredundant coated arrangement or 8C-TAIXB1 for the redundant coated arrangement. Preserve field-power selection, commons, grounding and channel numbering, and record every terminal before disconnecting the existing IOM.
Back up the control database before removal. After installation, inject authorized current values across the configured range, verify engineering-unit scaling and alarm limits, inspect channel quality and prove both paths where the redundant IOTA is used.
The module provides sixteen single-ended 4-20 mA channels with 16-bit conversion and a 50 ms input scan. Preserve transmitter power, polarity, current-return paths, controller scaling and alarm limits. Verify each configured range and bad-signal response during commissioning. Do not describe the module as HART-capable or as a voltage-input module.
Pair the IOM only with the documented coated IOTA arrangement and verify whether the installed cabinet is nonredundant or redundant. Record every terminal and configured channel before removal. After replacement, prove representative low, mid and high current values, alarm behavior, signal quality and redundant transfer where fitted.