Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
Honeywell identifies CC-PFB802 as the released Experion FOUNDATION Fieldbus FIM8 interface module replacing CC-PFB801. The direct manufacturer bulletin confirms model and role, but does not map additional website number 51454953-176 or provide electrical ratings. Verify the full supplied label, software release and connected fieldbus design.
The January 2019 Honeywell System Hints newsletter announces Experion FOUNDATION Fieldbus Interface Modules FIM4 and FIM8, identifying CC-PFB802 as the FIM8 and CC-PFB402 as the FIM4. It explicitly says the two newer modules replace CC-PFB801 and CC-PFB401 respectively. The notice also limits older parts to Experion servers operating at revision R400 or earlier. This establishes a model-level release and replacement context, but it is not a detailed module datasheet and must not be treated as proof of a universal drop-in replacement for any installed IOTA, firmware or fieldbus design.
Before procurement, check the complete CC-PFB802 label, hardware revision, installed Experion PKS release, fieldbus carrier, interface firmware, redundancy arrangement and connected H1 segments. Record segment power-conditioning design, terminators, cable topology and device load. The direct Honeywell bulletin does not map additional website number 51454953-176, so obtain confirmation from the actual supplied item or manufacturer parts record. It also provides no electrical ratings or shipping dimensions for this model; do not copy generic FIM4 values or unqualified reseller figures. After approved replacement, verify every affected segment and connected device under plant procedures.
Honeywell's bulletin identifies exact CC-PFB802 as an Experion FOUNDATION Fieldbus Interface Module designated FIM8. That is a role-level identification, not a complete electrical specification. Confirm the offered hardware's full label, revision and installed Series C carrier before representing it as an exact replacement in a particular control cabinet.
Honeywell states that CC-PFB802 replaces CC-PFB801, while the older part is retained only for systems with Experion servers at revision R400 or earlier. This announcement does not resolve every firmware, carrier or redundancy dependency. Review the actual plant release and current Honeywell compatibility guidance before implementing the change.
The reviewed direct Honeywell PDF is a January 2019 release bulletin. It does not map website number 51454953-176 and does not state the module's electrical ratings, size or packing weight. Verify those from the supplied item and an exact-model current technical document. Do not transfer FIM4 specifications or reseller-only claims into this FIM8 record.
Confirm CC-PFB802 on the physical module and verify additional website number 51454953-176 from its label or an OEM parts record. The direct Honeywell bulletin establishes that CC-PFB802 is the released Experion FOUNDATION Fieldbus FIM8 and replaces CC-PFB801. It does not specify the supplied module's electrical ratings, carrier selection or firmware. Match the installed Experion server release, Series C termination hardware and redundant architecture using current Honeywell documentation.
Record the original FIM label, firmware, carrier, fieldbus segment assignments, power conditioners, terminators, device count, status and diagnostic baseline. Follow approved plant isolation and ESD procedures. After installing a verified replacement, confirm module communication with the Experion system and check each affected H1 segment, device visibility, function-block operation and alarms. Do not assume a model-level release announcement proves a direct mechanical or configuration substitution in every cabinet.