Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Friday, November 6
Fast Shipping Available
Interconnection Cable Or Connector Assembly

MC-GHAO11 51309540-175

Product Information:

Honeywell's IO03-684 identifies MC-GHAO11 as the coated, GI/IS 16-output analog-output FTA with a HART connector and no standby-manual connectors, for use only with MU-PAOY22. The document lists MC-GHAO11 as a model but does not map numeric order suffix 51309540-175 to it separately; verify the full supplied marking and system configuration.

  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      Honeywell's IO03-684, TPS Process Manager I/O Specification and Technical Data, lists MC-GHAO11 as the coated model of a GI/IS analog-output 16-point FTA with a HART connector, without standby-manual connectors, and marked for use only with MU-PAOY22. The related GHAO11 family table specifies 16 channels of 4-20 mA, and provides model-specific limits including 870 ohms maximum resistive load at 20 mA and 17.4 V maximum output compliance under the table's 24 V supply = 20 V condition. The redundancy option lists a 20 ms maximum output gap on failover. These figures are from a Honeywell-authored 2012 family specification; it does not separately tie numeric order suffix 51309540-175 to the coated MC-GHAO11 model. Confirm the full marking, matched MU-PAOY22 IOP, intrinsic-safety design, field wiring and redundancy configuration before purchase or replacement.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Selected industrial-control settings for this industrial communications hardware include Oil & Gas, Chemical Processing, Marine & Shipbuilding and Pharmaceutical Manufacturing.

      Oil & Gas

      Serves production, compression and processing assets using compatible industrial communications hardware, subject to engineering review of the installed control architecture.

      Chemical Processing

      Supports reactors, blending systems and process utilities using compatible industrial communications hardware, with site requirements and the supplied revision confirmed.

      Marine & Shipbuilding

      Fits shipboard machinery and marine utility systems using compatible industrial communications hardware, after the installed configuration is confirmed.

      Pharmaceutical Manufacturing

      Applies to controlled production and clean-utility systems using compatible industrial communications hardware, when exact hardware and system compatibility are verified.
Technical specifications for

MC-GHAO11 51309540-175

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Listing order identity:
    51309540-175; numeric suffix mapping not separately verified in the reviewed OEM document
  • Assembly type:
    GI/IS analog output Field Termination Assembly (FTA)
  • Output points:
    16
  • Signal type:
    4-20 mA (GHAO11 family specification)
  • HART connector:
    Included per model description; the source does not claim a particular HART revision or full protocol behavior
  • Required IOP:
    MU-PAOY22 only
  • Standby manual connection:
    Not included
  • Maximum resistive load:
    870 ohms at 20 mA for GHAO11, with 24 V supply = 20 V condition
  • Maximum compliant voltage:
    17.4 V for GHAO11, with 24 V supply = 20 V condition
  • Calibrated accuracy:
    +/-0.45% at 25 C including linearity for MU-GHAO11 family entry; confirm application against installed configuration
  • Directly settable output current:
    0 mA; 2.9-21.1 mA
  • Output settling time:
    4 ms to 98% of final output value (digital input code)
  • Redundancy option:
    20 ms maximum output gap on failover; switching-hardware diagnostic once per minute
  • Product Type:
    Analog Output AO
  • The number of CH:
    16 channels
  • Current:
    4-20 mA
  • Connector Type:
    w/HART connector
  • Category Series:
    FTAs
  • Series:
    Honeywell DCS
  • Stock Availability:
    7
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

MC-GHAO11 MC-GHAO11 51309540-175 51309540-175 MCGHAO1151309540175 Honeywell GI/IS Analog Output 16 FTA Coated GI/IS AO FTA with HART connector

Information

Overview Manuals Model and Pairing Output Ratings Redundancy and Safety

Features:

  • Honeywell lists MC-GHAO11 as a coated 16-output GI/IS analog FTA with a HART connector and no standby-manual connectors.
  • The FTA is specified for use only with MU-PAOY22; the family table identifies 4-20 mA outputs and GHAO11-specific load/compliance limits.
  • Honeywell's redundancy-option table gives a 20 ms maximum output gap on failover; verify the actual redundant IOP/FTA design before application.

Honeywell's TPS Process Manager I/O specification (IO03-684, December 2012, Revision 2) lists MC-GHAO11 as the coated GI/IS analog-output FTA for 16 outputs, without standby-manual connectors and with a HART connector. The model table states that it is used only with MU-PAOY22 and that the MC models are conformally coated. The associated GHAO11 family specification is 4-20 mA with 16 channels. The document does not separately associate listing suffix 51309540-175 with this model, so that numeric mapping must be confirmed from the supplied item label.

Before installation, verify the complete FTA and IOP labels, approved I/O drawings, field-device and intrinsic-safety loop design, HART connector arrangement, redundancy use, and terminal/wiring details. Compare the loop burden with the GHAO11 family values under the stated supply condition; do not generalize ratings from the other 16-point FTA models in the same table. Follow the applicable Honeywell installation and safety instructions, and test each affected channel and alarm or failover behavior under the site's approved commissioning procedure before process release.

The MC-GHAO11 51309540-175 Honeywell GI/IS Analog Output FTA may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell MC-GHAO11 51309540-175 official technical documentation and product links.This multi-page Honeywell technical document contains the exact model and its technical data. Apply the values to the supplied type number and verify its revision before installation.

Honeywell lists MC-GHAO11 as the coated GI/IS analog-output FTA with a HART connector, without standby-manual connectors, for use only with MU-PAOY22. Confirm the exact FTA and IOP labels, connector style, coating and approved configuration. The model row does not independently map numeric order suffix 51309540-175 to MC-GHAO11.

The GHAO11 family table states 16 channels of 4-20 mA, an 870-ohm maximum resistive load at 20 mA and 17.4 V maximum compliant output under the stated 24 V supply = 20 V condition. It lists +/-0.45% calibrated accuracy at 25 C including linearity for MU-GHAO11. Apply these family figures only after confirming the exact matched IOP, supply and loop conditions; do not borrow limits from the other FTA models.

Honeywell's redundancy-option table lists a 20 ms maximum output gap on failover and switching-hardware diagnostics once per minute. The catalog marks the FTA for single or redundant applications, but the installed IOP, wiring and logic determine the actual arrangement. Confirm the intrinsic-safety design and approved process state, and test channels and failover under site procedures before return to service.

Technical notes

IO03-684 lists the coated MC-GHAO11 model, GI/IS 16-point analog-output function, HART connector, no standby-manual connectors and MU-PAOY22-only pairing. Its GHAO11 family table gives the ratings shown here. The reviewed document does not separately map 51309540-175 to MC-GHAO11, and the retrieved copy is mirrored rather than hosted on an official Honeywell domain. Confirm numeric suffix, actual labels and installed configuration. No verified weight, dimensions, country of origin or current lifecycle state is asserted.

Loop Burden and IOP Match

Confirm MU-PAOY22 is the connected processor and check each loop against the GHAO11 family limit of 870 ohms at 20 mA and 17.4 V maximum compliance under the specified 24 V supply = 20 V condition. Verify field-device demand, wiring resistance, barriers/isolators and supply conditions together; the table's other FTA model values differ. Record the channel assignments and test output scaling and HART-related connections using the approved commissioning procedure.

Redundant and GI/IS Installation

The source identifies the FTA as GI/IS, usable in single or redundant applications, and says the model has no standby-manual connectors. The separate redundancy table gives a maximum 20 ms output gap on failover for the named family. Confirm the site's approved intrinsic-safety entity/loop documentation, IOP redundancy hardware, channel configuration and safe-state behavior. Only qualified personnel should make changes; inspect the actual terminal/field barriers and verify channel and failover operation before process return.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    The reviewed OEM specification does not state verified package dimensions. Final packed dimensions are measured after protective packing.
  • Packed shipping weight
    Confirmed after final packing
    The reviewed OEM specification does not state verified net weight. Final gross shipping weight is measured after protective packing.
  • HS / customs code
    8538900000 (indicative reference)
    Indicative reference for an industrial control-system input/output part; the destination declarant confirms the final classification from the supplied item and shipment evidence.
  • Country of origin
    Confirm from supplied item
    Record origin only from the allocated unit's official marking or traceable manufacturer documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location, quantity and handling time are confirmed in the quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about MC-GHAO11 51309540-175

  • What should be checked before ordering MC-GHAO11?

    Match the full MC-GHAO11 marking and coating, the required MU-PAOY22 IOP, HART connector arrangement and GI/IS field interface. The reviewed specification lists MC-GHAO11 but does not separately map suffix 51309540-175 to the model; verify the actual supplied label and installed design.
  • Which IOP is it used with?

    The model table says MC-GHAO11 is used only with MU-PAOY22. Verify the installed IOP label and approved system configuration.
  • What output type and channel count are documented?

    The associated GHAO11 family specification lists 16 channels of 4-20 mA output.
  • What are the load and compliance limits?

    The GHAO11 family table states 870 ohms maximum resistive load at 20 mA and 17.4 V maximum compliant output under its stated 24 V supply = 20 V condition.
  • Does it include standby-manual connectors?

    No. Honeywell specifically notes that MU/MC-GHAO11 does not include standby-manual connectors.
  • Can it be used in a redundant system?

    The catalog marks the FTA for single or redundant applications. The redundancy option table gives a 20 ms maximum output gap on failover; confirm the installed IOP and switching hardware.
  • Does the OEM document confirm suffix 51309540-175?

    The reviewed document lists model MC-GHAO11, but does not separately map the numeric suffix 51309540-175 to it. Confirm the full supplied label.
  • What should be checked before replacement?

    Check the matched MU-PAOY22 processor, field-loop burden, HART connector arrangement, GI/IS design, exact module labels and redundant wiring; then test affected channels under site-approved procedures.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Obsolete/Discontinued by OEM

    Moore Automated supplies genuine-quality Honeywell MC-GHAO11 51309540-175 industrial automation component for maintenance and replacement of compatible installed systems. Every unit is carefully inspected before shipment, supporting dependable control-system maintenance and minimizing unexpected production downtime.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

MC-GHAO11 51309540-175
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.