Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
OPTIMATION INC OL2109
OPTIMATION INC OL2109
OPTIMATION INC OL2109
OPTIMATION INC OL2109
OPTIMATION INC OL2109
OPTIMATION INC OL2109
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Friday, November 27
Fast Shipping Available
8-Point DC Sinking Output Module

OL2109

Product Information:

OL2109 is an Optimation OptiLogic eight-point DC sinking output module using NPN open-collector transistor outputs for 5–40 VDC field loads.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      OL2109 is an Optimation OptiLogic eight-point DC sinking output module. Its NPN open-collector transistor outputs switch compatible 5–40 VDC field loads, with 300 mA maximum continuous current per documented point and a common field-supply arrangement. The Type 9, Subtype 2 identity, output wiring, card-cage position, field voltage and load characteristics must all match before replacement.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Applications describe qualified industry use and do not replace exact-system compatibility or functional-safety approval.

      Power Generation

      Supports qualified monitoring, control or communication duties in generating plants and auxiliary systems.

      Oil & Gas

      Supports approved process, machinery or network functions in production and compression facilities.

      Chemical Processing

      Integrates with verified continuous-process systems after exact hardware and interface matching.

      Water & Wastewater

      Supports qualified pumping, treatment and distribution systems with documented configuration controls.
Technical specifications for

OL2109

0 TECHNICAL PARAMETERS
  • Manufacturer:
    OPTIMATION INC
  • Product Category:
    General Automation
  • Module function:
    DC sinking output module
  • Output count:
    8 points
  • Output type:
    NPN open-collector transistor
  • Field-voltage range:
    5–40 VDC
  • Maximum continuous output current:
    300 mA per documented point
  • Peak output voltage:
    80 VDC
  • Isolation:
    500 VDC
  • Module identity:
    Type 9, Subtype 2
  • Stock Availability:
    2
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

Optimation OptiLogic OL2109 OptiLogic OL2109 OL-2109 OL2109 8-Point Sinking Output Module

Information

Overview Manuals Output Circuit Field Wiring Card-Cage Setup

Features:

  • Eight NPN open-collector sinking DC outputs.
  • Documented 5–40 VDC field-load range.
  • OptiLogic Type 9, Subtype 2 module execution.

OL2109 is an Optimation OptiLogic eight-point DC sinking output module. Its NPN open-collector transistor outputs switch compatible 5–40 VDC field loads, with 300 mA maximum continuous current per documented point and a common field-supply arrangement. The Type 9, Subtype 2 identity, output wiring, card-cage position, field voltage and load characteristics must all match before replacement.

Before removal, record the complete module marking, card-cage slot, field supply, common, output assignments, load currents and retained controller configuration. After installation, verify each output, polarity, isolation boundary, diagnostics and safe machine operation.

The OL2109 8-Point DC Sinking Output Module is listed as Obsolete / Discontinued by OEM. Current revision, availability and supplied scope are confirmed in the written quotation.
OL2109 Optimation OptiLogic official product documentation and Moore Automated resources.

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Verify the documented 8-Point DC Sinking Output Module function, exact identity and model-specific parameters before replacement. Preserve all installed settings and connected-hardware assignments.

Match the receiving platform, hardware execution, connector or terminal arrangement, field media and approved project documentation before installation.

After installation, inspect every connection, review diagnostics and complete controlled functional tests for each affected signal, link, alarm, interlock or control function.

Technical notes

Select OL2109 only after verifying the complete catalog identity, documented function, receiving-system compatibility, interfaces and retained configuration. Preserve the installed record and complete controlled diagnostics and functional testing before return to service.

Identity & System Matching

Confirm the complete OL2109 marking, documented 8-Point DC Sinking Output Module execution, receiving equipment, connected hardware and retained configuration before replacement.

Installation & Functional Test

Record the installed position and every interface before removal. After installation, verify diagnostics, signal or link performance and every affected control or protection function under the approved site procedure.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No verified exact-model warehouse dimensions were found; packed dimensions are recorded after protective packing.
  • Packed shipping weight
    Confirmed after final packing
    Final gross shipping weight is recorded after protective packing.
  • HS / customs code
    Confirmed for the destination
    Final classification depends on the declared item and destination.
  • Country of origin
    Confirmed from supplied item
    Verified from the product nameplate or traceable documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available documentation is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about OL2109

  • What is the exact identity of OL2109?

    OL2109 is the documented 8-Point DC Sinking Output Module; match every printed model, assembly and revision marking before replacement.
  • Which system must OL2109 match?

    Match the documented receiving platform, installed position, connectors or terminal hardware, field wiring and approved configuration.
  • Which interfaces require checking for OL2109?

    Confirm every electrical, optical or mechanical interface identified in the product parameters and the installed system record.
  • What should be recorded before removing OL2109?

    Record the complete label, installed position, connected hardware, wiring or fiber allocation, settings and retained configuration.
  • Can a nearby model replace OL2109?

    No direct interchangeability is assumed; compare the full catalog identity, hardware execution, interfaces and receiving-system documentation.
  • What must be tested after installing OL2109?

    Verify diagnostics and function-test every affected channel, link, output, alarm, interlock or control function under an approved procedure.
  • What should be checked when OL2109 arrives?

    Inspect the full identity, connector and housing condition, included items, readable markings and any requested certificates or inspection records.
  • What is required to quote OL2109?

    Provide the full model, quantity, condition, destination, readable label photographs and required certificates or inspection documentation.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Obsolete / Discontinued by OEM

    Moore Automated supplies OL2109 8-Point DC Sinking Output Module units for demanding industrial applications. Every unit is carefully inspected before shipment, supporting stable operation and reducing unexpected production downtime.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

OL2109
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.