ProSoft MVI46-ADMNET
ProSoft MVI46-ADMNET
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Tuesday, October 20
Fast Shipping Available
SLC Programmable Ethernet Communication Module

MVI46-ADMNET

Product Information:

MVI46-ADMNET is a ProSoft in-chassis programmable communication module for Allen-Bradley SLC systems, combining an Ethernet interface, serial ports and a user-programmable C application environment.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      MVI46-ADMNET is a ProSoft in-chassis programmable communication module for compatible Allen-Bradley SLC 500 systems. It combines an Ethernet interface, isolated application serial ports and a user-programmable C environment, allowing custom data handling and communication functions to operate directly in the control chassis. Selection must account for the SLC processor, chassis slot, backplane data exchange, port wiring and the application program stored in the module.

      Selection basis

      Match the complete MVI46-ADMNET identity, installed system, revision, connections and application before replacement.
    • INDUSTRY APPLICATIONS

      Where is it used?

      Typical industries using compatible systems and the documented product function are shown below.

      Industrial Manufacturing

      Enables custom Ethernet and serial data exchange in SLC-controlled production equipment.

      Water & Wastewater

      Supports programmed communication between SLC systems and compatible instruments or supervisory equipment.

      Material Handling

      Connects conveyors, storage systems and third-party devices through a custom in-chassis communication application.

      Energy & Utilities

      Provides programmable protocol and data-handling functions for legacy SLC installations in utility facilities.
Technical specifications for

MVI46-ADMNET

0 TECHNICAL PARAMETERS
  • Manufacturer:
    ProSoft
  • Product Category:
    General Automation
  • Host Platform:
    Allen-Bradley SLC 500
  • Slot Use:
    Single SLC chassis slot
  • Ethernet Ports:
    1 Port
  • Serial Ports:
    3 total; 2 isolated application ports
  • Programming Environment:
    User-programmable C application
  • Backplane Data:
    M0/M1 files
  • Stock Availability:
    1
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

MVI46ADMNET MVI46 ADMNET ProSoft MVI46 ADMNET

Information

Overview Manuals Port Architecture Application Software SLC Data Exchange

Features:

  • Occupies one compatible SLC chassis slot and exchanges data through the processor M0/M1 files.
  • Provides one Ethernet port plus configuration and two isolated application serial ports.
  • User C applications can implement custom data handling and protocol functions with the ProSoft development APIs.

The MVI46-ADMNET occupies one slot in a compatible Allen-Bradley SLC chassis and adds a programmable communication environment to the controller system. One Ethernet interface, a configuration serial port and two isolated application serial ports allow a user-developed C application to exchange and process information for connected devices while backplane data move through the processor's M0 and M1 files.

The module is used when a standard fixed-function interface does not provide the required data handling or protocol behavior. Its operation depends on both hardware and software: the SLC processor, chassis slot, ladder-logic data map, Ethernet parameters, serial electrical modes, cable pinouts, compiled program and source files must be preserved together before an installed module is replaced.

The MVI46-ADMNET ProSoft SLC Programmable Ethernet Communication Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
ProSoft MVI46-ADMNET documentation and reference links.Important Notice: The linked PDF is an official manufacturer document for this model or its documented exact product family. Confirm the complete order code, revision, connected hardware and installation requirements before replacement. Accessories, software and certificates are included only when stated in the written quotation.

Document the Ethernet port, configuration port and two isolated application serial ports, including every cable and electrical mode.

Back up the user C source, compiled application, configuration files and any ProSoft API dependencies before replacing the module.

Verify the processor supports the required M0/M1 files, match the slot and ladder logic, then test the full data map after installation.

Technical notes

MVI46-ADMNET contains application-specific software. Before removal, preserve the compiled application, source where available, Ethernet settings, serial port modes, cable pinouts, SLC slot and M0/M1 data map.

SLC Backplane and Port Architecture

MVI46-ADMNET occupies one compatible Allen-Bradley SLC chassis slot and provides one Ethernet interface, a configuration serial port and two isolated application serial ports. Backplane data are exchanged with the processor through M0 and M1 files.

Application and Data Transfer

The module runs a user-programmable C application using the ProSoft development APIs. Preserve the source and executable, Ethernet settings, serial modes, cable pinouts, SLC slot and ladder-logic data map before replacement.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No official exact-model packed dimensions are published; final dimensions are recorded after protective packing.
  • Packed shipping weight
    Recorded after final packing
    Final gross shipping weight is recorded after the supplied item and protective packing are checked.
  • HS / customs code
    Not officially confirmed
    The final customs classification is confirmed by the destination customs declarant.
  • Country of origin
    Confirm from supplied item
    The supplied unit nameplate and shipment documents are checked before dispatch.
  • Ships from
    Xiamen, Fujian, China
    The dispatch location, quantity and handling time are confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Invoice, packing-list and origin-document requirements are agreed with the order.
PRODUCT & ORDER FAQS

Questions buyers ask about MVI46-ADMNET

  • What problem does the MVI46-ADMNET solve in an SLC 500 system?

    It provides a programmable in-chassis environment for custom Ethernet and serial communication or data-handling functions that are not covered by a fixed-function interface.
  • Which SLC hardware must be checked before installing MVI46-ADMNET?

    Confirm the compatible SLC processor, available chassis slot, backplane power and support for the M0 and M1 files used by the module.
  • Which physical communication ports are available on the module?

    It provides one Ethernet interface, a configuration serial port and two isolated application serial ports for the user program.
  • How does the custom application exchange data with the processor?

    The C application reads and writes the defined data map through the SLC processor's M0 and M1 backplane files.
  • Which application files must be preserved before module replacement?

    Back up the C source, compiled executable, configuration files, build information and any ProSoft API dependencies needed to reproduce the application.
  • What Ethernet settings should be recorded from the operating module?

    Record IP address, subnet mask, gateway, port use, client or server roles and every peer or host expected by the application.
  • Which serial-port details are essential for a like-for-like replacement?

    Record RS-232/422/485 mode, baud rate, data bits, parity, stop bits, handshaking, cable pinouts and connected-device addresses.
  • How should MVI46-ADMNET communication be validated after installation?

    Verify the SLC data map, Ethernet sessions, both isolated application ports, diagnostics and the complete end-to-end workflow implemented by the custom program.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    MVI46-ADMNET is supplied only after the complete model, revision, condition and included hardware are checked against the written quotation.

    The module runs a user-programmable C application using the ProSoft development APIs. Preserve the source and executable, Ethernet settings, serial modes, cable pinouts, SLC slot and ladder-logic data map before replacement.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

MVI46-ADMNET
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.