Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
ProSoft PLX31-EIP-MBS4
ProSoft PLX31-EIP-MBS4
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Thursday, November 5
Fast Shipping Available
EtherNet/IP to Modbus Serial Four-Port Communication Gateway

PLX31-EIP-MBS4

Product Information:

The ProSoft Technology PLX31-EIP-MBS4 is a four-port EtherNet/IP-to-Modbus Serial communication gateway for bidirectional data exchange between EtherNet/IP automation controllers or devices and Modbus Serial equipment.

For replacement, match PLX31-EIP-MBS4, the hardware revision, connectors, installed position and receiving-system configuration.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      The ProSoft Technology PLX31-EIP-MBS4 is a four-port EtherNet/IP-to-Modbus Serial communication gateway for bidirectional data exchange between EtherNet/IP automation controllers or devices and Modbus Serial equipment. For replacement, match PLX31-EIP-MBS4, the hardware revision, connectors, installed position and receiving-system configuration.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Industry uses for the documented ethernet/ip to modbus serial four-port communication gateway function.

      Water & Wastewater

      Connects serial instruments and meters to EtherNet/IP pump and treatment controls.

      Utilities & Metering

      Bridges Modbus serial power monitors into compatible controller data tables.

      Process Skids

      Links serial analyzers and packaged equipment with EtherNet/IP plant controllers.

      Industrial Manufacturing

      Integrates legacy Modbus serial devices into EtherNet/IP machine networks.
Technical specifications for

PLX31-EIP-MBS4

0 TECHNICAL PARAMETERS
  • Manufacturer:
    ProSoft
  • Product Category:
    General Automation
  • Manufacturer:
    ProSoft Technology
  • Product Type:
    EtherNet/IP to Modbus Serial communication gateway
  • EtherNet/IP Connections:
    5 Class 3 server connections; 8 Class 1 I/O connections
  • EtherNet/IP Messages:
    PCCC and CIP
  • Maximum RPI:
    5 ms per connection
  • Serial Ports:
    4
  • Serial Interfaces:
    RS-232, RS-422 or RS-485
  • Serial Baud Rate:
    110 baud to 115.2 kbps
  • Serial Port Isolation:
    2500 Vrms
  • Ethernet Port:
    10/100 Mbit RJ45, full or half duplex
  • Power Supply:
    24 V DC nominal; 10 to 36 V DC allowed
  • Current Load:
    300 mA at 24 V DC nominal; 610 mA maximum
  • Operating Temperature:
    -25 to +70 °C
  • Enclosure:
    IP20, NEMA/UL Open Type; DIN rail
  • Product Dimensions (H x W x D):
    13.67 x 5.05 x 11.13 cm
  • Stock Availability:
    1
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

ProSoft four-port EtherNet/IP Modbus Serial gateway ProSoft PLX31-EIP-MBS4 PLX31 EIP MBS4

Information

Overview Manuals EtherNet/IP Interface Modbus Serial Ports Installation Checks

Features:

  • Four serial ports bridge Modbus Serial equipment to an EtherNet/IP control system.
  • Documented interfaces include RS-232, RS-422, RS-485, PCCC and CIP.
  • The gateway uses a 24 V DC nominal supply and a DIN-rail IP20 enclosure.

PLX31-EIP-MBS4 is a four-port ProSoft gateway that exchanges data between EtherNet/IP controllers and Modbus Serial equipment. Its documented host-side compatibility includes ControlLogix and CompactLogix controllers.

Before replacement, confirm the controller project, serial mode, register map, port wiring, power source and firmware/configuration file. Do not infer the connected device count or controller compatibility from the gateway model alone. PLX31-EIP-MBS4 ProSoft EtherNet/IP to Modbus Serial Four-Port Gateway may remain available through Moore Automated beyond the manufacturer lifecycle; current OEM lifecycle status is not verified in the reviewed source.

The PLX31-EIP-MBS4 may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
PLX31-EIP-MBS4 documentation and reference links. Important Notice: Confirm the complete catalog identity, hardware revision, receiving-system configuration and required document revision before replacement.

Confirm the configured controller family, connection type, RPI, message format and data sizes in the running project. The datasheet lists five Class 3 server connections and eight Class 1 I/O connections; actual topology remains project-dependent.

Configure each of the four ports for the connected device and documented RS-232, RS-422 or RS-485 interface. Verify address, baud rate, parity, data size, stop bits, RTU or ASCII mode and register mapping before commissioning.

Verify the 24 V DC supply within the documented 10 to 36 V DC range, DIN-rail mounting, protective enclosure, serial isolation and grounding. Back up the gateway configuration and confirm data exchange on every used port before returning equipment to service.

Technical notes

The PLX31-EIP-MBS4 is a gateway, not an Ethernet switch or a stand-alone Modbus meter. Match the EtherNet/IP controller project, serial device map, 24 V DC supply, RS-232/422/485 wiring and port isolation before commissioning.

Network Protocols

PLX31-EIP-MBS4 exchanges data between EtherNet/IP controllers and Modbus Serial devices. The manufacturer lists PCCC and CIP message support, five Class 3 server connections, eight Class 1 I/O connections and a maximum 5 ms RPI per connection.

Serial and Power

The unit provides four serial ports with RS-232, RS-422 or RS-485 support. Its nominal supply is 24 V DC (10 to 36 V allowed), with 300 mA typical load at 24 V DC and 610 mA maximum. Serial ports are isolated to 2500 Vrms.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No official packed dimensions for PLX31-EIP-MBS4 were confirmed; the final carton is measured after protective packing.
  • Packed shipping weight
    Confirmed after final packing
    No official gross shipping weight for PLX31-EIP-MBS4 was confirmed; the packed shipment is weighed before dispatch.
  • HS / customs code
    Confirmed for destination
    The destination customs declarant confirms the applicable tariff line for the supplied item and order.
  • Country of origin
    Confirm from supplied item
    Record origin only from the allocated unit nameplate or traceable manufacturer documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location, quantity and handling time are confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Invoice, packing-list and origin-document requirements are agreed with the order.
PRODUCT & ORDER FAQS

Questions buyers ask about PLX31-EIP-MBS4

  • Which installed system and function should be matched for PLX31-EIP-MBS4?

    It is ProSoft Technology's four-port EtherNet/IP to Modbus Serial communication gateway.
  • How many serial ports does the gateway provide?

    The exact MBS4 model provides four serial communication ports.
  • Which serial electrical interfaces are documented?

    The manufacturer lists RS-232, RS-422 and RS-485 interfaces.
  • Which EtherNet/IP connection counts are listed?

    The datasheet specifies five Class 3 server connections and eight Class 1 I/O connections.
  • Which installed system and function should be matched for PLX31-EIP-MBS4?

    The nominal supply is 24 V DC, with a documented allowed range of 10 to 36 V DC.
  • What must match in the serial configuration?

    Verify baud rate, parity, data size, stop bits, node address, wiring and register mapping against the running project.
  • Which installed system and function should be matched for PLX31-EIP-MBS4?

    The reviewed exact-model datasheet does not confirm current lifecycle or orderability; check with ProSoft at quotation.
  • Are shipping weight, packed size and origin confirmed?

    No exact packed weight, packed dimensions or country of origin are asserted; confirm them from the supplied item and dispatch documents.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Availability for PLX31-EIP-MBS4 is confirmed at quotation. The complete model, condition and included hardware are checked before shipment.

    Any alternative is proposed only after the receiving system, interfaces, configuration and commissioning requirements have been reviewed.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

PLX31-EIP-MBS4
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.