Woodward 5466-031 is a legacy NETCON I/O Controller used with the LON-based LINKnet I/O architecture. It provides the controller-side network interface for documented LINKnet nodes and must be matched to the installed MicroNet control hardware, network wiring and application configuration.
5466-031 is the Woodward NETCON I/O Controller used with the original LON-based LINKnet architecture. Its role is to connect the controlling MicroNet system to documented distributed field nodes. The complete part number, hardware revision, receiving controller and network design must match the controlled installation record.
Before replacement, record the chassis position, connectors, network wiring, termination, node addresses, node types, power arrangement, diagnostics and application revision. Do not treat a later LINKnet HT component as a drop-in replacement. After installation, verify controller status, network communication and every affected field input and output under the site commissioning procedure.
5466-031 belongs to the legacy LON-based LINKnet architecture. Match the controller module, network media, termination, address plan and field-node types to the controlled system record.
Use the controller only with documented legacy LINKnet nodes and the approved MicroNet application. Confirm every node identity and channel map; a visually similar node or later network component is not automatically compatible.
Woodward identifies CANopen LINKnet HT as a different architecture. A migration requires engineering review of controller hardware, field nodes, wiring, application software, diagnostics and commissioning tests.
Woodward identifies 5466-031 as a NETCON I/O Controller. It is used with the original LON-based LINKnet field network and must remain matched to the receiving MicroNet controller, network termination, node addresses and approved application.
Record the complete hardware label and all connected node identities before replacement. Do not assign generic voltage, current-loop or temperature ratings to this controller module.
Woodward states that regular production of the related LON LINKnet architecture ended in April 2015. Existing spares can support like-for-like service, while migration to CANopen LINKnet HT requires hardware and software changes.
After replacement, verify controller diagnostics, network communication, each node status and every affected field channel. A migration must be commissioned as an engineered system change.
Woodward states that regular production of the related LON LINKnet architecture ended in April 2015.
Moore Automated confirms the offered 5466-031 unit's condition, hardware revision, availability and supplied scope in the written quotation. Like-for-like service must preserve the original LON LINKnet design; migration to CANopen LINKnet HT requires hardware, software and commissioning changes.