Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
Woodward 9905-760
Woodward 9905-760
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Sunday, November 8
Fast Shipping Available
LINKnet Termination Network

9905-760

Product Information:

Woodward 9905-760 is the LINKnet termination network for the LINKnet I/O option used with Woodward 723 Digital Controls.

For replacement, match 9905-760, the hardware revision, connectors, installed position and receiving-system configuration.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      Woodward 9905-760 is the LINKnet termination network for the LINKnet I/O option used with Woodward 723 Digital Controls. For replacement, match 9905-760, the hardware revision, connectors, installed position and receiving-system configuration.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Industry uses for the documented linknet termination network function.

      Power Generation

      Supports distributed sequencing and monitoring in compatible 723 generator-control systems.

      Engine-Driven Compression

      Terminates remote LINKnet I/O serving compressor-package auxiliaries.

      Industrial Turbines

      Supports non-time-critical sequencing and monitoring around turbine control packages.

      Marine Engine Rooms

      Terminates compatible distributed I/O in vessel engine-control cabinets.
Technical specifications for

9905-760

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Woodward
  • Product Category:
    Process Control
  • Product Type:
    LINKnet termination network
  • Manufacturer Part Number:
    9905-760
  • Compatible System:
    Woodward LINKnet I/O option for 723 Digital Controls
  • Installation Position:
    Last LINKnet I/O module on the network
  • Network Trunk Capacity:
    Up to 60 I/O modules per 723 LINKnet channel trunk (system limit)
  • Network Cable:
    Shielded twisted pair; Manual 02826 specifies listed Level V type
  • Network Polarity:
    No polarity on LINKnet network wiring
  • Shield EMC Practice:
    Land shield at each I/O module; exposed shield wire limited to 25 mm (1 in)
  • Stock Availability:
    3
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

Woodward 9905-760 9905 760 9905760

Information

Overview Manuals Network Placement Cable & Shielding Addressing & Compatibility

Features:

  • Installed at the last LINKnet I/O module on the network, not at an arbitrary intermediate node.
  • Used with the Woodward LINKnet I/O option for 723 Digital Controls; trunk capacity is a system limit of.
  • Manual 02826 specifies shielded twisted-pair wiring, no network-wire polarity, and no more than 25 mm of exposed shield.

Woodward 9905-760 is identified in Product Manual 02826 as the termination network for the LINKnet I/O option on 723 Digital Controls. It is a network-end component: the manual requires it at the last LINKnet I/O module on a trunk. It does not perform the sensing, control logic or output work of the I/O modules themselves.

The 723 LINKnet channel can serve independent trunks of up to 60 modules. Each node's address must match its configured application address in the 1–60 range. Confirm the exact part marking, 723 LINKnet option, trunk layout, last-node position, address plan and wiring drawing before replacement.

The 9905-760 may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
9905-760 documentation and reference links. Important Notice: Confirm the complete catalog identity, hardware revision, receiving-system configuration and required document revision before replacement.

Manual 02826 requires one 9905-760 termination network at the last LINKnet I/O module on the network. The part is not a substitute for the controller's LINKnet interface or for the LINKnet nodes. Preserve the documented bus end point when changing a module or rerouting the trunk.

A 723 LINKnet channel may provide independent trunks with up to 60 I/O modules. Woodward describes node addresses 1–60 and requires each module's rotary-switch address to match the application-program definition. The count and address range describe the network, not a separate rating of the termination part.

Use the documented shielded twisted-pair LINKnet cable; Manual 02826 specifies listed Level V type. The network wiring has no polarity, but follow the terminal diagram for the installed module and control. Do not treat the absence of polarity as permission to ignore terminal assignment or grounding.

For EMC performance, the manual says to land the cable shield at each I/O module and limit exposed shield wire to 25 mm (1 in). At the 723, strip the outer insulation and land the bare shield to chassis as shown in the installation instructions. Verify isolation and safe-work requirements before service.

Confirm the 723 Digital Control's LINKnet option, configured trunk, application address list, installed I/O node sequence and last-node position. Each node address must match the configured address; the documented range is 1–60 per trunk.

Manual 02826 describes LINKnet for non-time-critical control functions such as sequencing and monitoring. Check the current controller project, wiring revisions and system-specific safety review; do not infer compatibility with other Woodward control families from the 9905-760 number alone.

Technical notes

Install 9905-760 at the last LINKnet I/O module on the network. Verify the 723 LINKnet option, trunk topology, node addresses and current application configuration. Use documented shielded twisted-pair cable; land shields as specified and limit exposed shield wire to 25 mm (1 in) at I/O modules. Confirm terminal assignment and safe-work procedure from current Woodward documentation before commissioning or replacement.

Network Placement & Termination

Install the 9905-760 termination network at the last LINKnet I/O module on the network. Do not place it at an intermediate node or substitute it for the 723 LINKnet controller interface. Confirm the correct end point from the network drawing before removing an installed unit.

A 723 LINKnet channel supports up to 60 modules per independent trunk. Treat this as the network's node limit; it is not a channel count or load rating for the 9905-760.

Network Wiring & Shielding

Use the shielded twisted-pair cable specified for LINKnet; Woodward Manual 02826 specifies listed Level V type. The network conductors have no polarity, but follow terminal labels and the project wiring diagram.

For EMC, land the cable shield at each I/O module and keep exposed shield wire to 25 mm (1 in) or less. At the 723, strip outer insulation and land the bare shield to chassis as instructed by the manual. Isolate and inspect the system using the approved site procedure.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No official packed dimensions for 9905-760 were confirmed; the final carton is measured after protective packing.
  • Packed shipping weight
    Confirmed after final packing
    No official gross shipping weight for 9905-760 was confirmed; the packed shipment is weighed before dispatch.
  • HS / customs code
    Confirmed for destination
    The destination customs declarant confirms the applicable tariff line for the supplied item and order.
  • Country of origin
    Confirm from supplied item
    Record origin only from the allocated unit nameplate or traceable manufacturer documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location, quantity and handling time are confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Invoice, packing-list and origin-document requirements are agreed with the order.
PRODUCT & ORDER FAQS

Questions buyers ask about 9905-760

  • Which installed system and function should be matched for 9905-760?

    It is the LINKnet termination network identified in Woodward Manual 02826 for LINKnet I/O used with 723 Digital Controls; it is not an I/O module.
  • Where does 9905-760 install on a LINKnet trunk?

    Manual 02826 requires the termination network at the last LINKnet I/O module on the network, not at an intermediate node.
  • Which Woodward control family is documented for 9905-760?

    The reviewed manual covers the LINKnet option for 723 Digital Controls; verify the installed controller and project configuration before ordering.
  • How many LINKnet modules may share a 723 trunk?

    Manual 02826 describes independent trunks with up to 60 I/O modules, addressed 1 through 60; this is a network limit, not the terminator's rating.
  • Does LINKnet network wiring have polarity?

    Woodward states that the LINKnet network wiring has no polarity, but the installed module terminal diagram and project wiring still govern connections.
  • What cable does the 9905-760 installation use?

    Manual 02826 specifies shielded twisted-pair LINKnet cable and listed Level V cable type; confirm the project cable specification before replacement.
  • How should the LINKnet cable shield be handled?

    For EMC, land the shield at each I/O module, keep exposed shield wire to 25 mm or less, and land the bare shield to chassis at the 723 as instructed.
  • What should be checked before replacing 9905-760?

    Match the part marking, 723 LINKnet option, trunk endpoint, last-module location, module address list, shield termination and current wiring revision.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Availability for 9905-760 is confirmed at quotation. The complete model, condition and included hardware are checked before shipment.

    Any alternative is proposed only after the receiving system, interfaces, configuration and commissioning requirements have been reviewed.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

9905-760
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.