Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
TU843 is an ABB Redundant for the documented Advant S800 I/O platform. Verified configuration includes Type Redundant, Connection Terminal block, Channels 16, Voltage 50 V. Confirm the complete identity, hardware revision, interfaces and receiving-system configuration before replacement; verify affected functions after installation.
TU843 is an ABB Redundant selected by its complete product identity and documented Advant S800 I/O equipment role. Its verified execution includes Type Redundant; Connection Terminal block; Channels 16; Voltage 50 V; Mounting Vertical; Use with I/O AI843, AO845, AO845A, DI840, DI880, DO840, DO880 and DP840; Maximum current per I/O channel 3 A. These values distinguish the supplied hardware from visually similar revisions and must match the approved receiving-system record.
Before installing TU843, record the complete nameplate, hardware revision, installed position, connector or terminal allocation, paired assemblies and relevant settings. Compare the supplied unit with the approved ABB documentation, isolate affected energy sources, preserve grounding and configuration data, then complete diagnostics and controlled functional checks before return to service.
ABB TU843 documentation and reference links.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
TU843 performs the documented module termination unit function within the Advant S800 I/O platform. Verified product data includes Channels 16; Voltage 50 V; Mounting Vertical; Mounting detail 55 º (131 °F); Single/redundant I/O Redundant; Maximum current per I/O channel 3 A. These values and the complete hardware revision must match the supplied unit.
Integrate TU843 only with the approved Advant S800 I/O receiving hardware, connector or terminal arrangement and paired assemblies. Preserve all recorded settings, then verify each affected interface and diagnostic path after installation.
Before energizing TU843, inspect mounting, connector keying, wiring allocation, protective grounding and connected equipment. Review status indications and diagnostics, then complete controlled functional tests before service release.
TU843 verified technical data: Channels 16; Voltage 50 V; Mounting Vertical; Mounting detail 55 º (131 °F); Single/redundant I/O Redundant; Maximum current per I/O channel 3 A; Maximum current process connection 10 A; Dielectric test voltage 500 V a.c.; Temperature, Operating 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C; Temperature, Storage -40 to +70 °C (-40 to +158 °F). Use these values only with the complete product identity and documented Advant S800 I/O receiving-system record.
Match TU843 to the approved mounting position, terminal or connector arrangement, power and signal interfaces, paired assemblies and configuration record. After installation, verify every affected function and diagnostic indication.
Active / Available from OEM
Moore Automated supplies the ABB TU843 Redundant through exact-item verification and qualified supply channels. Every supplied unit is checked for identity, revision, physical condition and included items before shipment to support stable operation and reduce unplanned downtime.