991-01-XX-01-00 is a Bently Nevada 991 Two-Wire Thrust Transmitter that converts axial shaft-position/thrust input from one 3300 NSv proximity-probe system into an industry-standard 4–20 mA two-wire loop signal. The ordered full-scale code resolves to 01 — not defined in the current official ordering table; verify the controlled order/MOD record, and the system-length code resolves to XX — not defined in the current official ordering table; verify the controlled order/MOD record.
The 991-01-XX-01-00 accepts one 3300 NSv proximity-probe system and converts axial shaft position into a proportional 4–20 mA current-loop output for thrust-position monitoring. The transmitter operates from +12 to +35 Vdc, supports up to 1000 Ω loop resistance at 35 Vdc, and provides a buffered Prox Out signal for commissioning measurements.
This order code records 01 — not defined in the current official ordering table; verify the controlled order/MOD record, XX — not defined in the current official ordering table; verify the controlled order/MOD record, 35 mm DIN-rail clips and agency approval not required. Before replacement, preserve the established zero/reference position, verify probe/cable compatibility, loop polarity and scaling, and prove the NOT OK response without changing the machine protection setpoints.
991-01-XX-01-00 uses the documented 01 — not defined in the current official ordering table; verify the controlled order/MOD record execution to convert axial shaft position into its 4–20 mA loop signal. Commission the receiving channel against this exact range, preserve polarity and engineering units, and retain the established thrust datum, alarms and trip logic.
991-01-XX-01-00 records XX — not defined in the current official ordering table; verify the controlled order/MOD record for the matched 3300 NSv probe and extension-cable chain. Confirm the combined electrical length, connector condition, probe gap and buffered Prox Out response before accepting the loop reading.
991-01-XX-01-00 records 35 mm DIN-rail clips with agency approval not required. Match the physical mounting hardware, terminal access, grounding and approval marking, then prove the NOT OK response through the receiving system without changing protection setpoints.
The 991-01-XX-01-00 scales 01 — not defined in the current official ordering table; verify the controlled order/MOD record axial shaft position to a 4–20 mA two-wire output. Preserve the mechanical reference, polarity and thrust alarm positions while verifying the +12 to +35 Vdc supply and total loop resistance at several known displacement points.
Use the matched XX — not defined in the current official ordering table; verify the controlled order/MOD record 3300 NSv chain and confirm the 0.25–1.65 mm buffered Prox Out linear range without allowing probe contact. An input fault must drive the loop below 3.6 mA within 100 µs and valid input should restore operation within 0.1 second.