82000000011000 is the order code for SM-PROFIBUS DP-V1, the PROFIBUS DP-V1 option module for supported legacy drives. It supports 9.6 kbit/s to 12 Mbit/s, up to 32 input and 32 output cyclic words, PROFIdrive V2/V4 and DP-V1 acyclic parameter access.
82000000011000 SM-PROFIBUS DP-V1 connects a supported host drive to a PROFIBUS network. The official guide documents PROFIdrive V2/V4 profiles, DP-V1 parameter access, non-cyclic communication and drive identification functions.
Before removal, record the label, host drive, slot, node address, baud behavior, process-data mapping, GSD revision and cable termination. After installation, load the verified configuration and prove cyclic data, parameter access and drive interlocks.
Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The module supports PROFIBUS data rates from 9.6 kbit/s through 12 Mbit/s. The installed node address, cable topology, shielding and termination must match the approved network design.
Use the correct GSD file and preserve the original master configuration and process-data mapping before replacement.
Up to 32 input and 32 output cyclic words are supported. DP-V1 adds acyclic parameter access alongside the standard cyclic data exchange.
Confirm word order, PPO or mapping selection, PROFIdrive profile, parameter channel and timeout behavior from the running installation.
The module is powered from the host drive internal supply and must be fitted only in a supported option slot. Match the complete module label and host-drive firmware.
After installation, verify network status, cyclic I/O, DP-V1 parameter access, drive enable chain, command source, reference scaling and fault handling before production.
Match the module label, host drive, option slot, node address, GSD file, process-data words and PROFIdrive configuration. Do not substitute another fieldbus option by connector appearance.
Inspect cable, shielding and termination, then prove master communication, cyclic control and status words, acyclic parameter access, drive commands, references, interlocks and fault response under the approved site procedure.
Obsolete / Discontinued by OEM
The legacy SM communication-module family belongs to discontinued drive platforms. Exact revision, condition, GSD compatibility, included connector and host-drive support are confirmed in the written quotation.