Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
General Electric UR8MH
General Electric UR8MH
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Thursday, November 5
Fast Shipping Available
Sensitive-Ground CT/VT Module

UR8MH

Product Information:

UR8MH is the GE Multilin Universal Relay 8M CT/VT option with sensitive-ground 4 CT and 4 VT inputs plus enhanced diagnostics. Confirm the host Universal Relay model, slot, firmware, CT/VT secondary ratings, grounding and terminal assignments before replacement.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      GE Multilin UR8MH, also written UR-8MH, is the Universal Relay 8M CT/VT DSP option. Current GE Vernova ordering data defines 8M as sensitive-ground 4 CT/4 VT with enhanced diagnostics. It is a relay input module, not a digital I/O card. Confirm the host UR relay model, slot, firmware, CT and VT secondary ratings, terminal assignment and complete order code before replacement.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      The module is used in compatible GE Multilin Universal Relay protection systems requiring four current and four voltage inputs with sensitive-ground measurement.

      Power Generation

      Current, voltage and sensitive-ground measurement in compatible generator and motor protection relays.

      Transmission & Distribution

      Analog CT/VT inputs in documented substation protection and control schemes.

      Industrial Power Systems

      Protection measurement for qualified feeder, transformer and motor applications.

      Oil & Gas

      Electrical protection of approved motors, feeders and utility systems in process facilities.
Technical specifications for

UR8MH

0 TECHNICAL PARAMETERS
  • Manufacturer:
    General Electric
  • Product Category:
    General Automation
  • Manufacturer:
    GE Multilin / GE Vernova
  • Module code:
    UR 8M
  • Product type:
    CT/VT DSP input module
  • Current transformer inputs:
    4 CT inputs
  • Voltage transformer inputs:
    4 VT inputs
  • Ground measurement:
    Sensitive-ground input configuration
  • Diagnostics:
    Enhanced CT/VT diagnostics
  • Compatible platform:
    Supported GE Multilin Universal Relay models and firmware
  • Identity to verify:
    UR8MH / UR-8MH complete supplied marking
  • Stock Availability:
    3
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

GE UR8MH GE Multilin UR-8MH UR 8M CT/VT Module Sensitive Ground 4CT/4VT Module UR 8MH

Information

Overview Manuals CTVT Inputs Relay Compatibility Protection Commissioning

Features:

  • 8M option provides sensitive-ground 4 CT / 4 VT inputs.
  • Enhanced diagnostics support current and voltage input supervision.
  • Designed for compatible GE Multilin Universal Relay platforms.

UR8MH conditions current-transformer and voltage-transformer secondary signals for the relay protection and measurement functions. The host relay provides the configured protection logic; the module supplies the analog CT/VT interface.


Before replacement, save the relay settings file and record the complete relay order code, slot, firmware, CT/VT ratios, nominal frequency, grounding and terminal wiring. After installation, verify measurements, phase sequence, ground channel and protection-element operation.


The GE Multilin UR8MH Sensitive-Ground CT/VT Module is listed as Active / Available from OEM. Current revision, availability and supplied scope are confirmed in the written quotation.
GE Vernova Multilin Universal Relay Ordering Data, Link

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

The 8M option contains four CT inputs and four VT inputs with a sensitive-ground configuration and enhanced diagnostics. Confirm which physical channel is assigned to the ground-current circuit in the installed relay.

Match CT secondary current, VT secondary voltage, frequency, phase rotation, grounding and terminal assignment to the approved protection drawing.

UR module compatibility depends on the exact relay family, chassis generation, slot, firmware and complete order code. Verify the relay model and hardware option table before installation.

Do not substitute 8L, 8M, 8N, 8R or earlier 8G/8H/8J/8K modules without a documented protection-engineering review.

Save the complete relay settings and retrieve oscillography or metering references before work. Observe CT-secondary safety and site isolation procedures.

After replacement, verify all current and voltage channels, phase sequence, sensitive-ground response, diagnostics, metering and every affected protection element using approved secondary-injection tests.

Technical notes

Treat UR8MH as the 8M sensitive-ground 4CT/4VT input module, not digital I/O. Match the host relay and complete order code, observe CT-secondary safety, and complete measurement and secondary-injection testing after replacement.

CT/VT Identity & Safety

Match UR8MH/UR-8MH, the host relay, slot and firmware. Apply CT-secondary safety controls and verify CT/VT ratings, polarity, grounding and terminal allocation before disturbing wiring.

Metering & Protection Test

Restore the approved relay file, verify all phase and ground measurements, then complete secondary-injection tests for every affected metering, alarm, trip and protection function.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No verified exact-model warehouse dimensions were found; packed dimensions are recorded after protective packing.
  • Packed shipping weight
    Confirmed after final packing
    No verified exact-model warehouse weight was found; final gross shipping weight is recorded after protective packing.
  • HS / customs code
    Confirmed for the destination
    Final classification depends on the declared item and destination.
  • Country of origin
    Confirmed from supplied item
    Verified from the product nameplate or traceable documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available documentation is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about UR8MH

  • How is the exact UR8MH item identified?

    Match UR8MH on the supplied label and confirm the complete hardware revision, connectors and installed platform before replacement.
  • Which compatibility details must be checked?

    Confirm the host Universal Relay model, chassis generation, slot, firmware, complete order code, CT and VT secondary ratings, frequency, polarity and terminal assignment.
  • What should be recorded before removal?

    Record the complete label, revision, slot or mounting position, connector allocation, wiring, network settings and retained configuration before disturbing the installed item.
  • Can a nearby family model be substituted?

    No direct substitution is assumed. The function, hardware revision, electrical interface, protocol, firmware and installed-system requirements must match the approved design.
  • What should be inspected when the item arrives?

    Inspect the label, connectors, enclosure or circuit board, supplied accessories and packaging. Confirm the ordered model and condition before installation.
  • What should be tested after installation?

    Verify CT/VT metering, phase sequence, sensitive-ground measurement, diagnostics and every affected alarm, trip and protection element by approved secondary injection.
  • What information is required for a quotation?

    Provide UR8MH, quantity, required condition, destination, label photos and any revision, certificate, inspection or test-record requirements.
  • How is availability confirmed?

    Exact revision, condition, included items, lead time and compatibility are confirmed in the written quotation before supply.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Active / Available from OEM

    Current GE Vernova Universal Relay ordering documents list the 8M CT/VT DSP option. Exact module revision, host-relay compatibility, condition and supplied scope are confirmed in the written quotation.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

UR8MH
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.