Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China

The General Electric QPM-2D100-L2P is a 5-inch monochrome stn lcd touch screen hmi for the GE QuickPanel platform. It provides a local operator interface for machine monitoring, status display and control. Confirm the complete model code, hardware revision, interfaces and supplied condition against the installed equipment before replacement.
Verify that the supplied item is marked QPM-2D100-L2P and that its 5-inch monochrome stn lcd touch screen hmi, designed for 24v dc power input form, connectors and revision agree with the approved GE QuickPanel receiving record.
For QPM-2D100-L2P, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.
Apply only parameters supported by the exact QPM-2D100-L2P record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.
QPM-2D100-L2P technical scope: Supply Voltage: 24 VDC; Power Consumption: Approximately 10–20 W (typical: 12–15 W); Power Supply Tolerance: Designed to withstand industrial-grade power fluctuations within standard control system environments; Dielectric Withstand Voltage (Isolation Strength): 1500 VAC for 1 minute (typical); Noise Immunity: 1000 Vp-p pulse noise suppression capability (pulse width: 1 μs), ensuring robust EMC performance in electrically noisy industrial environments.
Use these values only for the listed hardware execution and verify the supplied label before installation.
Match QPM-2D100-L2P to the approved GE QuickPanel receiving position, connector or terminal arrangement and configuration record.
After power restoration, review diagnostics and test the affected 5-inch monochrome stn lcd touch screen hmi, designed for 24v dc power input path.
Active / Available from OEM
QPM-2D100-L2P is a General Electric 5-inch monochrome stn lcd touch screen hmi, designed for 24v dc power input associated with the GE QuickPanel platform. It interfaces the documented field signals with the control system through the assigned channels, terminals and installed I/O position. Correct selection depends on the complete model code, connector or terminal arrangement, hardware revision and receiving-system configuration. Before replacement, compare the original product label, installed slot or cabinet reference, connected assemblies and approved project records. After installation, review system diagnostics and function-test every affected channel, control path, protection function or communication link before returning the equipment to service.