Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
Honeywell DCS MU-KFTA05 51201420-005 is a 5 m FTA I/O Cable for the documented receiving system.
For replacement, match MU-KFTA05 51201420-005, the hardware revision, connectors, installed position and receiving-system configuration.
Page 58 of Honeywell's IO03-500 TPS Process Manager I/O specification lists a family of FTA I/O cables with telephone-style connectors. MU-KFTA05 is the five-meter entry; MU-KFTA10 and higher model numbers denote other listed lengths. Immediately below, Honeywell distinguishes shielded FTA I/O cables as MU-KFTSxx. The designation therefore supports a specific cable role and length but not a generic claim that MU-KFTA05 has a braided shield. The cited table also does not provide electrical or environmental ratings for this individual cable. Selection must be based on the approved system documentation and actual cable marking.
Before replacing an installed FTA I/O cable, qualified personnel should identify the I/O processor and FTA endpoints, check the route and connector style, and record existing tags and connection orientation. Compare the complete MU-KFTA05 and 51201420-005 markings with the approved bill of materials; the latter number is present in the site's identity but is not cross-referenced by the reviewed Honeywell specification. After authorized isolation and fitting, inspect connector retention and cable routing, then prove affected I/O paths under the site's test plan. The source does not establish current Honeywell availability, hot-swap permission or interchangeability with another length or shielded variant.
Honeywell's model-number table identifies MU-KFTA05 as the five-meter FTA I/O cable. The reviewed page does not state that the site's additional 51201420-005 number is an official alternate identifier. Check both numbers on the allocated physical cable and in the manufacturer's parts record. Do not infer the properties of other MU-KFTA lengths from this one model.
The OEM table groups MU-KFTA05 in the telephone-connector version of FTA I/O cables. The separate MU-KFTSxx line is explicitly the shielded FTA I/O cable family. The current site's prior shielded, impedance and capacitance claims are not supported by this exact-model page. Match the installed cable construction and connectors to the original cabinet drawing before selecting a replacement.
Record both I/O and FTA endpoints, routing length, tags and connector orientation before an authorized cable change. Use the site's isolation and process-safety procedure, not a generic hot-swap assumption. After installation, inspect seating and routing, confirm hardware diagnostics and test every affected I/O point. The Honeywell model table does not establish current support status or interchangeable variants.
Use the complete MU-KFTA05 designation when checking the manufacturer's table: it denotes the five-meter FTA I/O cable in the telephone-connector version. The 51201420-005 number on this site's record must be checked on the supplied label and approved parts record. The OEM page does not provide impedance, capacitance, conductor gauge, jacket material or a temperature rating, so these should not be used as selection criteria without separate manufacturer evidence.
Confirm the installed I/O processor, field termination assembly, connector type and route length before removing the existing cable. Follow qualified isolation and system-specific maintenance procedures. Fit only the approved cable execution, inspect both connector seats and routing, then verify diagnostics and each affected I/O point against a documented test plan. The reviewed Honeywell specification does not authorize energized replacement or prove equivalence with shielded MU-KFTSxx versions.