Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
Schneider Electric catalog reference 47059 identifies the Micrologic 6.0 P electronic control unit with LSIG protection and power-meter measurement for compatible MasterPact NT and NW circuit breakers. The S047059 notation is retained as a supplied-item reference, while breaker frame, sensor and rating-plug details must be verified from the installed assembly.
Schneider Electric catalog reference 47059 identifies the Micrologic 6.0 P electronic control unit with long-time, short-time, instantaneous and ground-fault protection. It adds power and energy metering for compatible MasterPact NT and NW circuit breakers. The S047059 notation is retained as a supplied-item reference.
Before replacement, record the complete breaker and trip-unit labels, protection settings, sensor and rating plug, ZSI wiring, auxiliary power, communications, alarms and event history. After installation, restore only the approved settings and test LSIG protection, trip indication, metering, communication and breaker operation before returning the switchgear to service.
Micrologic 6.0 P provides long-time, short-time, instantaneous and ground-fault protection. Record every pickup and delay setting, the rating plug, sensor and ZSI arrangement before replacement.
The Micrologic P platform provides current, voltage, power, energy, frequency and power-factor measurements together with event and alarm functions. Confirm auxiliary power, communication and programmable contact options.
Schneider documents the control unit for compatible MasterPact NT and NW circuit breakers. Verify the exact breaker frame, sensor, rating plug, trip-unit execution and communication accessories before installation.
Schneider Electric catalog reference 47059 identifies a Micrologic 6.0 P control unit with LSIG protection and power-meter measurement. The unit includes an integrated display and keypad for settings, measurements, alarms and event information.
Record the complete protection setting set, sensor and rating plug, ZSI wiring, auxiliary power and option configuration before removal.
Use the control unit only with the documented MasterPact NT or NW breaker and verified frame, sensor, rating plug and accessories. Another Micrologic 6.0 execution is not automatically interchangeable.
After installation, test long-time, short-time, instantaneous and ground-fault protection, trip indication, measurements, alarms, communication and breaker operation under the approved procedure.
Schneider Electric regional pages show differing lifecycle and service states for catalog reference 47059.
Moore Automated confirms availability, condition and supplied scope in the written quotation for the destination. Match the complete Micrologic 6.0 P execution, MasterPact NT or NW breaker, frame, sensor, rating plug, protection settings and communication options; no substitution from a family name alone is asserted.