Allen-Bradley 1756-IA16I
Allen-Bradley 1756-IA16I
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Monday, September 21
Fast Shipping Available
Digital AC Input Module

1756-IA16I

Spare Part Number

PN1756IA16I 1756-IA16I/A

Product Information:

The Allen-Bradley 1756-IA16I is a ControlLogix 16-point isolated AC input module. It is designed to connect standard AC field signals (such as limit switches, pushbuttons, and motor starter contacts) to Allen-Bradley ControlLogix PAC (Programmable Automation Controller) systems. A key feature of this module is its point-to-point isolation, ensuring that each input channel is electrically isolated from other channels.

The 1756-IA16I operates from 79 to 132V AC and from 47 to 63 Hz. This module can be installed directly into a 1756 local or remote chassis.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
Technical specifications for

1756-IA16I

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Allen-Bradley
  • Product Category:
    PLC and Machine Control
  • Spare Part Number:
    1756IA16I 1756-IA16I/A
  • Estimated shipping dimensions:
    23.3x18.2x5.3cm
  • Weight:
    0.35 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Line:
    ControlLogix
  • Inputs:
    16 Individually Isolated
  • Module Type:
    Digital AC Input Module
  • No. of Inputs:
    Sixteen (16) Individually Isolated
  • Input Voltage:
    120 Volts AC
  • Operating Voltage Range:
    79-132 Volts AC
  • Input Delay Time:
    Programmable 9 or 18 milliseconds
  • Minimum Operating Current:
    5 milliamperes at 79 Volts AC, 47-63 Hertz
  • Maximum Operating Current:
    15 milliamperes at 132 Volts AC, 47-63 Hertz
  • Maximum Input Current, Off-State:
    2.5 milliamperes
  • Power Dissipation (Max):
    4.9 Watts at 60 degrees Celsius
  • Backplane Current at 5 Volts:
    125 milliamperes
  • Backplane Current at 24 Volts:
    2 milliamperes
  • Series:
    Allen-Bradley ControlLogix
  • Stock Availability:
    20
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Revisions

Revision Part #

Also known as

1756-IA16I/A
1756-IA16I Ser A, Series A, Rev A

Alternative Names

1756IA16I 1756 IA16I I756-IAI6I 1756-1A161 1756-I416I I756-1AI61 1756-IA16IA 1756-IA16IK 1756-IA16 1756-IA16K 1756-IN16 1756-IN16K 1756-TBCH 1756-TBS6H

Information

Overview Manuals Channel-to-Channel Isolation Advantages Wiring & Accessories

Features:

  • ControlLogix 16-point Isolated AC Input Module
  • 74V AC to 132V AC (nominal 120V AC) at a frequency of 47 Hz to 63 Hz
  • This module has Sixteen (16) individually isolated channels
The Allen-Bradley 1756-IA16 is a ControlLogix I/O module. This isolated AC digital input module features a display showing input and communication status, as well as module operating conditions. Each input channel is independently isolated, with a rated continuous input voltage of 125 volts per channel. The module can be directly connected to a ControlLogix chassis. Compatible removable terminal block housings are the 1756-TBCH and 1756-TBS6H.

This module can be installed in a local or remote I/O ControlLogix chassis. A local ControlLogix chassis refers to the component with a ControlLogix processor installed, while a remote I/O chassis refers to a ControlLogix chassis that communicates with the local chassis via a communication adapter.

The 1756-IA16I Allen Bradley Digital AC Input Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Allen Bradley 1756-IA16I Digital AC Input Module Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
Because this module features point-to-point isolation (250V continuous rated voltage between channels), it is ideal for harsh industrial environments:
Multiple power supplies: It allows you to connect field inputs from completely different phases, transformers, or external control panels to a single module without short circuits.
Ground loop protection: Electrical noise or grounding faults on one field device will not propagate and affect signals in adjacent channels.
This module can be installed in any standard 1756 ControlLogix chassis slot.
It requires separate purchase of removable terminal blocks (RTBs) for field wiring:
1756-TBCH: 36-pin cage-clamp RTB.
1756-TBS6H: 36-pin spring-clamp RTB.

Technical notes

The Allen-Bradley 1756-IA16I is a 16-channel 120V AC digital input module for ControlLogix systems, characterized by complete isolation between channels. Operating from 79-132V AC, the module supports software-configurable filtering and state change (COS) interrupts and is designed for high-isolation industrial automation applications.
PRODUCT & ORDER FAQS

Questions buyers ask about 1756-IA16I

  • How does the 1756-IA16I, with its 16 independently isolated AC input channels and 79–132V AC operating range, ensure high integrity discrete signal acquisition within the ControlLogix architecture?

    The 1756-IA16I is designed to provide reliable field AC signal monitoring while maintaining channel-to-channel isolation, thereby enhancing system integrity and fault tolerance.
  • Why is the 1756-IA16I considered a mission-critical digital input module requiring 16 independently isolated AC signal processing points in ControlLogix systems?

    The 1756-IA16I offers superior electrical isolation, enhanced noise immunity, and reliable signal detection in harsh industrial environments.
  • What operational advantages does the 1756-IA16I offer through its 16 isolated input points, 50/60 Hz compatibility, and ControlLogix backplane integration?

    The 1756-IA16I enhances input reliability while simplifying the acquisition of field-level AC status signals in distributed automation systems.
  • How does the 1756-IA16I maintain excellent signal integrity and immunity to electrical noise through independently isolated channels when handling discrete AC input signals of 79–132V?

    The 1756-IA16I minimizes signal interference between channels, thereby improving measurement accuracy and system availability.
  • How does the 1756-IA16I enhance the reliability of industrial automation through independent channel isolation and deterministic AC input status monitoring?

    The 1756-IA16I accurately detects the status of field devices while reducing the risk of cross-channel electrical interference.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

1756-IA16I
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.