The General Electric IC695PSA140 is a multipurpose 120/240vac or 125vc power supply, 40 watts for the PACSystems RX3i platform. It performs its documented equipment function within the installed industrial system. Confirm the complete model code, hardware revision, interfaces and supplied condition against the installed equipment before replacement.
Verify that the supplied item is marked IC695PSA140 and that its multipurpose 120/240vac or 125vc power supply, 40 watts form, connectors and revision agree with the approved PACSystems RX3i receiving record.
For IC695PSA140, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.
Apply only parameters supported by the exact IC695PSA140 record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.
IC695PSA140 technical scope: Nominal Rated Voltage: 120/240 VAC or 125 VDC; Input Voltage Range AC: 85 to 264 VAC; Input Voltage Range DC: 100 to 300 VDC; Output Power: 40 Watts maximum total 5.1 VDC = 30 Watts maximum 3.3 VDC = 30 Watts maximum The maximum total output power available depends on the ambient temperature, as shown.; Number of PSA140 Power Supplies in Universal Backplane: Up to 4.
Use these values only for the listed hardware execution and verify the supplied label before installation.
Match IC695PSA140 to the approved PACSystems RX3i receiving position, connector or terminal arrangement and configuration record.
After power restoration, review diagnostics and test the affected multipurpose 120/240vac or 125vc power supply, 40 watts path.
Active / Available from OEM
IC695PSA140 is a General Electric multipurpose 120/240vac or 125vc power supply, 40 watts associated with the PACSystems RX3i platform. It supports the documented power-conversion and distribution duty assigned to the installed rack or cabinet position. Correct selection depends on the complete model code, connector or terminal arrangement, hardware revision and receiving-system configuration. Before replacement, compare the original product label, installed slot or cabinet reference, connected assemblies and approved project records. After installation, review system diagnostics and function-test every affected channel, control path, protection function or communication link before returning the equipment to service.