HACH DR3900 LPV440.99.00002
HACH DR3900 LPV440.99.00002
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Thursday, September 24
Fast Shipping Available
Visible Spectrophotometer Without RFID

DR3900 LPV440.99.00002

Product Information:

HACH DR3900 LPV440.99.00002 is a benchtop visible spectrophotometer without RFID, covering 320–1100 nm with a halogen light source and reference-beam optical design.

It provides a 7-inch 800 × 480 TFT display, more than 220 stored programs, up to 100 user programs and capacity for 2000 measurement records. Confirm the exact order number, regional power cord and accessory set before use.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      HACH DR3900 LPV440.99.00002 is the non-RFID visible spectrophotometer execution for laboratory and process-water analysis. The exact order number, power arrangement, cuvettes, reagents and analytical methods must be verified before use.

      Official source

      HACH official DR3900 product record for order LPV440.99.00002.
    • APPLICATIONS

      Where it may be used

      Use the instrument only with validated methods, compatible reagents and a controlled laboratory or process-testing environment.

      Drinking water

      Routine photometric testing in municipal water laboratories.

      Wastewater

      Process and discharge analysis using validated HACH methods.

      Food & beverage

      Water-quality and process-sample checks in production laboratories.

      Environmental labs

      Visible-range testing for documented water and sample methods.
Technical specifications for

DR3900 LPV440.99.00002

0 TECHNICAL PARAMETERS
  • Manufacturer:
    HACH
  • Product Category:
    Process Control
  • Product type:
    Benchtop visible spectrophotometer
  • Order number:
    LPV440.99.00002
  • RFID option:
    Without RFID
  • Wavelength range:
    320 nm to 1100 nm
  • Light source:
    Halogen lamp
  • Optical system:
    Reference beam
  • Display:
    7-inch TFT, 800 × 480
  • Data storage:
    2000 measurement records
  • Stored programs:
    More than 220
  • User programs:
    Up to 100
  • Enclosure rating:
    IP30
  • Power supply:
    110–240 V AC, 50/60 Hz
  • Stock Availability:
    1
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

DR3900 LPV440.99.00002 HACH DR3900 Without RFID

Information

Overview Manuals Optical System Methods and Memory Laboratory Setup

Features:

  • Non-RFID benchtop visible spectrophotometer.
  • 320–1100 nm range with halogen lamp and reference-beam optics.
  • More than 220 stored programs, up to 100 user programs and 2000 data records.

Confirm order number LPV440.99.00002, regional power cord, cuvettes and reagent compatibility before use.

DR3900 is a visible-range laboratory spectrophotometer for programmed and user-defined water-analysis methods. Measurement quality depends on correct method selection, compatible cells and reagents, and routine verification of the optical system.

Official source: HACH official DR3900 product record.
DR3900 LPV440.99.00002 verified Moore Automated product resources. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

The DR3900 covers 320–1100 nm using a halogen lamp and reference-beam optical system. Keep the optical compartment clean and use compatible cells.

The instrument supports more than 220 stored programs, up to 100 user programs and 2000 measurement records. Use only validated methods and reagents.

Place the instrument on a stable dry bench, verify the 110–240 V AC supply and regional cord, then complete the required quality-control checks before sample testing.

Technical notes

HACH DR3900 order LPV440.99.00002 is the non-RFID benchtop visible spectrophotometer execution with a 320–1100 nm wavelength range, halogen light source, reference-beam optics, a 7-inch 800 × 480 TFT display, more than 220 stored programs, up to 100 user programs and storage for 2000 measurement records. Verify the exact order number, regional power cord, cuvette and reagent compatibility, accessory scope and site conditions before installation; place the instrument on a stable dry bench, complete the required quality-control checks and use only the approved analytical procedures for the sample and method.

Visible Spectral Measurement

The non-RFID DR3900 uses a 320–1100 nm spectral range, halogen source and reference-beam design. Confirm the exact LPV440.99.00002 order number.

Method and Sample Control

Select the validated analytical program, compatible reagent and clean cuvette for the sample. Complete blank, standard and quality-control checks required by the method.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    HACH product dimensions: 151 × 350 × 255 mm.
  • Packed shipping weight
    Confirmed after final packing
    HACH product net weight: 4.2 kg.
  • HS / customs code
    Not officially confirmed
    Verify the applicable classification for the destination before shipment.
  • Country of origin
    Not officially confirmed
    Verify from the instrument nameplate or COO.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about DR3900 LPV440.99.00002

  • How is the correct DR3900 execution identified?

    Match the exact HACH order number LPV440.99.00002 and confirm that this execution is specified without RFID.
  • What wavelength range does the instrument cover?

    The official product record specifies 320 nm to 1100 nm.
  • How many methods can the DR3900 store?

    Official data lists more than 220 stored programs and up to 100 user programs.
  • Where is this DR3900 typically applied?

    Typical uses include drinking-water, wastewater, environmental, food and beverage, and industrial-water analysis.
  • What should be checked before installation?

    Verify the regional power cord, cuvette and reagent compatibility, instrument location, ventilation and the required analytical method.
  • How is stock confirmed?

    Current stock, condition and the exact accessory scope are confirmed in the written Moore Automated quotation.
  • What warranty applies?

    The standard Moore independent-supplier warranty is 12 months from shipment unless the quotation states otherwise.
  • How is the instrument prepared for transport?

    The optical instrument and accessories are protected against shock and moisture; packed size and weight are confirmed after final packing.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    The official DR3900 record is current; the exact supplied condition and accessory scope require confirmation in the written quotation.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

DR3900 LPV440.99.00002
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.