Honeywell technical specifications

MC-ZLLMF2

Product Information:

MC-ZLLMF2 is Honeywell's LLMUX IOP firmware upgrade kit for using existing Process Manager I/O with a C300 controller. The manufacturer catalog lists one low-level multiplexer IOP firmware EPROM and one 28-pin protective boot. It is an upgrade component set for a compatible installed IOP, not a complete controller, new input module or USB cable.

  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      MC-ZLLMF2 is a hardware-delivered firmware upgrade kit for the low-level multiplexer input/output processor used in Honeywell PMIO installations. Honeywell lists it among the kits that enable compatible existing PMIO to be used with C300 controllers. The supply consists of a firmware EPROM and its protective boot, so the receiving IOP and its installed field connections remain separate items. Selection depends on the exact LLMUX processor and the planned controller release. The kit does not independently provide measurement channels, a new field terminal assembly or a complete migration of the cabinet.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Selected process-industry settings for this industrial communications hardware include Chemical Processing, Food & Beverage, Pharmaceutical Manufacturing and Pulp & Paper.

      Chemical Processing

      Serves reactors, blending systems and process utilities using compatible industrial communications hardware, after the installed configuration is confirmed.

      Food & Beverage

      Supports batching, thermal processing and packaging utilities using compatible industrial communications hardware, when exact hardware and system compatibility are verified.

      Pharmaceutical Manufacturing

      Fits controlled production and clean-utility systems using compatible industrial communications hardware, subject to engineering review of the installed control architecture.

      Pulp & Paper

      Applies to pulping, recovery and paper-machine operations using compatible industrial communications hardware, with site requirements and the supplied revision confirmed.
Technical specifications for

MC-ZLLMF2

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Honeywell
  • Product Category:
    DCS Systems
  • Kit function:
    LLMUX IOP firmware upgrade
  • Target I/O processor:
    Existing low-level multiplexer IOP in the PMIO family
  • Controller application:
    Use of compatible existing PMIO with C300 controllers
  • Firmware component:
    Low-level mux IOP firmware EPROM
  • EPROM quantity:
    1 per cataloged kit
  • Protective component:
    28-pin protective boot
  • Boot quantity:
    1 per cataloged kit
  • Firmware revision:
    Verify the supplied EPROM marking against the required system release
  • Product Type:
    Protective Boot, 28 Pin
  • Catalog Description:
    LLMUX IOP Firmware Upgrade Kit
  • Using Method:
    Existing PMIO with C300 controllers
  • Series:
    Honeywell DCS
  • Stock Availability:
    9
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

MCZLLMF2 MC ZLLMF2 MC-ZLLMF2 LLMUX Upgrade Kit

Information

Overview Manuals Kit Components PMIO to C300 Upgrade Checks

Features:

  • Model-specific firmware kit for the low-level multiplexer IOP, within Honeywell's PMIO-to-C300 upgrade offering.
  • The cataloged hardware set contains one low-level mux IOP firmware EPROM and one protective boot for 28 pins.
  • The existing IOP, field termination hardware and controller are separate from the kit; their compatibility and required release must be checked before the upgrade.

The MC-ZLLMF2 is intended for a specific part of a PMIO modernization project: changing the firmware used by the low-level multiplexer IOP. Honeywell's April 2021 Kits and Enhancements Catalog places it in the PMIO firmware-upgrade section for use of existing I/O with C300 controllers. The kit includes one firmware EPROM and one 28-pin protective boot. Neither the IOP card nor a C300 controller is listed as part of this kit, so purchasing it should not be treated as purchasing a complete input-processing or control assembly.

Before selecting the kit, record the receiving IOP's complete identification and its existing firmware label, then match them to the intended controller and software release. Have the responsible system engineer confirm the upgrade path and the approved installation procedure, including configuration backup and post-upgrade checks. The catalog identifies the kit contents and purpose but does not establish an unrestricted replacement relationship for every low-level input product. It also does not specify the delivered EPROM revision, which must be verified from the supplied kit and the applicable project documentation.

The MC-ZLLMF2 Honeywell LLMUX IOP Firmware Upgrade Kit may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Honeywell MC-ZLLMF2 official technical documentation and product links.This multi-page Honeywell technical document contains the exact model and its technical data. Apply the values to the supplied type number and verify its revision before installation.

Honeywell's catalog lists one low-level mux IOP firmware EPROM and one protective boot for 28 pins. The EPROM entry is on catalog page 53 and the boot entry continues on page 54. Confirm that the quotation supplies the complete kit, with readable component identification and suitable protective packaging; an unlabelled loose device is not enough to establish the required firmware execution.

The documented purpose is to allow compatible existing PMIO to be used with a C300 controller. For this kit the receiving processor is the low-level multiplexer IOP. Confirm the installed processor type and the planned Experion/controller release. The cataloged upgrade purpose does not mean that all PMIO variants, low-level input cards or remote hardened multiplexers use the same kit.

Plan the work using the approved Honeywell instructions for the receiving hardware and the site's controlled maintenance procedure. Record the current firmware and configuration, protect the EPROM against electrostatic damage and verify the supplied marking before installation. After the upgrade, check the IOP's reported status and the affected measurements under the project's commissioning plan. Do not infer a live-change or hot-swap permission from this catalog listing.

Technical notes

The April 2021 Honeywell Kits and Enhancements Catalog identifies MC-ZLLMF2 as an LLMUX IOP firmware upgrade kit. Its bill of materials spans pages 53 and 54: one firmware EPROM and one 28-pin protective boot. The catalog does not state a supplied firmware revision, chip memory capacity or electrical ratings for the complete kit. These are not replaced by specifications from a different IOP or a USB cable.

Receiving IOP and Release Match

Provide the installed low-level multiplexer IOP's complete part number, hardware revision and existing EPROM marking when requesting the kit. Include the target controller and system release so the responsible engineer can check the approved migration path. LLMUX, low-level analog input and remote hardened multiplexer kits have distinct catalog entries; a similar abbreviation does not establish interchangeability. Confirm the kit execution and required instructions before arranging a maintenance window.

Kit Completeness and Work Scope

The supply boundary is one firmware EPROM and one 28-pin protective boot, as listed across the two catalog pages. Confirm whether any additional instructions, installation service or replacement receiving hardware are required and explicitly included in the quotation. Keep the supplied component markings and packaging records for receiving inspection. Firmware installation, configuration recovery and operational testing are separate project activities and should be performed by qualified personnel under the applicable site procedure.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    The manufacturer kit listing does not give packed dimensions. Length, width and height are recorded after the EPROM and protective boot are secured in suitable antistatic and protective packaging.
  • Packed shipping weight
    Confirmed after final packing
    No verified net weight is stated in the reviewed exact-kit entry. The final gross weight is measured with all supplied components and protective packaging.
  • HS / customs code
    Confirm for the supplied kit
    The shipment contains a programmed EPROM and protective boot, not a complete PLC. The customs declarant must confirm classification from the actual component set and destination tariff; a generic controller code is not asserted.
  • Country of origin
    Confirm from supplied item
    Origin is recorded from the actual supplied kit's marking or traceable manufacturer documentation, not inferred from the brand or dispatch address.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location, quantity and handling time are confirmed in the quotation.
  • Customs documents
    Confirmed for the destination
    Available document scope is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about MC-ZLLMF2

  • What should be checked before ordering MC-ZLLMF2?

    Identify the installed LLMUX IOP, its present firmware marking and the required C300 system release before ordering. Confirm both cataloged kit components and follow the approved Honeywell upgrade procedure for the receiving hardware.
  • What does the cataloged kit include?

    One low-level mux IOP firmware EPROM and one 28-pin protective boot. Honeywell's catalog splits these entries across pages 53 and 54, both of which are retained in the linked excerpt.
  • Which hardware must be matched?

    Match the installed LLMUX IOP, its current firmware marking and the planned controller/software release. Obtain the approved upgrade instructions for that configuration; other PMIO firmware kits are not automatically interchangeable.
  • Is a specific firmware revision guaranteed?

    The reviewed catalog entry does not identify the revision delivered in a particular kit. Confirm the actual EPROM label and the required system release in the quotation and engineering review before installation.
  • Where is it used, and how is it installed?

    It can support PMIO modernization in refineries, chemical plants, power stations and paper mills that retain compatible multiplexer measurement I/O. Qualified personnel should follow the approved receiving-hardware procedure, preserve configuration records and verify the affected measurements after the upgrade.
  • Is MC-ZLLMF2 in stock?

    The page shows the listed stock quantity. Request written confirmation of allocation, firmware marking and complete kit contents before ordering; the displayed quantity does not reserve a particular execution.
  • What warranty is provided?

    Moore Automated offers a one-year warranty. The written quotation confirms condition, coverage, warranty start date and return procedure for the supplied kit.
  • How is the kit packed and shipped?

    The EPROM and boot are protected with suitable antistatic and shipping packaging. Final packed dimensions, gross weight, dispatch time and destination documents are confirmed for the actual shipment; origin requires supplied-item evidence.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Obsolete/Discontinued by OEM

    Moore Automated supplies genuine-quality Honeywell MC-ZLLMF2 industrial automation component for maintenance and replacement of compatible installed systems. Every unit is carefully inspected before shipment, supporting dependable control-system maintenance and minimizing unexpected production downtime.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

MC-ZLLMF2
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.