Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China

MC-ZLLMF2 is Honeywell's LLMUX IOP firmware upgrade kit for using existing Process Manager I/O with a C300 controller. The manufacturer catalog lists one low-level multiplexer IOP firmware EPROM and one 28-pin protective boot. It is an upgrade component set for a compatible installed IOP, not a complete controller, new input module or USB cable.
The MC-ZLLMF2 is intended for a specific part of a PMIO modernization project: changing the firmware used by the low-level multiplexer IOP. Honeywell's April 2021 Kits and Enhancements Catalog places it in the PMIO firmware-upgrade section for use of existing I/O with C300 controllers. The kit includes one firmware EPROM and one 28-pin protective boot. Neither the IOP card nor a C300 controller is listed as part of this kit, so purchasing it should not be treated as purchasing a complete input-processing or control assembly.
Before selecting the kit, record the receiving IOP's complete identification and its existing firmware label, then match them to the intended controller and software release. Have the responsible system engineer confirm the upgrade path and the approved installation procedure, including configuration backup and post-upgrade checks. The catalog identifies the kit contents and purpose but does not establish an unrestricted replacement relationship for every low-level input product. It also does not specify the delivered EPROM revision, which must be verified from the supplied kit and the applicable project documentation.
Honeywell's catalog lists one low-level mux IOP firmware EPROM and one protective boot for 28 pins. The EPROM entry is on catalog page 53 and the boot entry continues on page 54. Confirm that the quotation supplies the complete kit, with readable component identification and suitable protective packaging; an unlabelled loose device is not enough to establish the required firmware execution.
The documented purpose is to allow compatible existing PMIO to be used with a C300 controller. For this kit the receiving processor is the low-level multiplexer IOP. Confirm the installed processor type and the planned Experion/controller release. The cataloged upgrade purpose does not mean that all PMIO variants, low-level input cards or remote hardened multiplexers use the same kit.
Plan the work using the approved Honeywell instructions for the receiving hardware and the site's controlled maintenance procedure. Record the current firmware and configuration, protect the EPROM against electrostatic damage and verify the supplied marking before installation. After the upgrade, check the IOP's reported status and the affected measurements under the project's commissioning plan. Do not infer a live-change or hot-swap permission from this catalog listing.
Provide the installed low-level multiplexer IOP's complete part number, hardware revision and existing EPROM marking when requesting the kit. Include the target controller and system release so the responsible engineer can check the approved migration path. LLMUX, low-level analog input and remote hardened multiplexer kits have distinct catalog entries; a similar abbreviation does not establish interchangeability. Confirm the kit execution and required instructions before arranging a maintenance window.
The supply boundary is one firmware EPROM and one 28-pin protective boot, as listed across the two catalog pages. Confirm whether any additional instructions, installation service or replacement receiving hardware are required and explicitly included in the quotation. Keep the supplied component markings and packaging records for receiving inspection. Firmware installation, configuration recovery and operational testing are separate project activities and should be performed by qualified personnel under the applicable site procedure.