Product Information:

Smart Link DP AC1335 is a IFM as-i profibus-dp gateway used within the IFM AS-Interface and PROFIBUS-DP network. It provides the specified as-i profibus-dp gateway function while retaining the complete order code, hardware execution and receiving-system compatibility during replacement. Its documented gateway function is AS-Interface to PROFIBUS-DP.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      Smart Link DP AC1335 belongs to the IFM AS-Interface SmartLink and performs the documented as-i profibus-dp gateway role in the IFM AS-Interface and PROFIBUS-DP network. The retained technical evidence records Gateway Function: AS-Interface to PROFIBUS-DP; AS-i Masters: 1 integrated master; Operating Voltage: 26.5 to 31.6 V DC from AS-i. The full marking, receiving hardware, connectors or terminals, configuration dependencies and installed position must be matched before substitution.

      Selection basis

      Select Smart Link DP AC1335 by its complete hardware identity and the approved receiving-system record; appearance alone does not establish interchangeability.
    • APPLICATIONS

      Where it may be used

      Typical industries for the documented as-i profibus-dp gateway execution.

      Process Control

      Supports as-i profibus-dp gateway duties in the documented control architecture.

      Power Utilities

      Maintains controller, I/O and protection functions in plant auxiliary systems.

      Manufacturing

      Restores machine and process automation hardware during planned maintenance.

      System Upgrades

      Preserves the exact IFM AS-Interface SmartLink execution in approved modernization work.
Technical specifications for

Smart Link DP AC1335

0 TECHNICAL PARAMETERS
  • Manufacturer:
    IFM Electronic
  • Product Category:
    General Automation
  • Gateway Function:
    AS-Interface to PROFIBUS-DP
  • AS-i Masters:
    1 integrated master
  • Operating Voltage:
    26.5 to 31.6 V DC from AS-i
  • Current Consumption:
    Less than 200 mA from AS-i
  • Display:
    Backlit 128 x 64 graphic LCD
  • Operating Temperature:
    0 to 60 °C
  • Protection Rating:
    IP20
  • Mounting:
    DIN rail
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

AC1335 IFM AC1335 AC1335 AS-i PROFIBUS-DP Gateway

Information

Overview Manuals Bus Interface Platform Match Startup Review

Features:

  • AS-i PROFIBUS-DP Gateway for the documented IFM AS-Interface SmartLink.
  • Gateway Function: AS-Interface to PROFIBUS-DP.
  • AS-i Masters: 1 integrated master.
Smart Link DP AC1335 belongs to the IFM AS-Interface SmartLink and performs the documented as-i profibus-dp gateway role in the IFM AS-Interface and PROFIBUS-DP network. The retained technical evidence records Gateway Function: AS-Interface to PROFIBUS-DP; AS-i Masters: 1 integrated master; Operating Voltage: 26.5 to 31.6 V DC from AS-i. The full marking, receiving hardware, connectors or terminals, configuration dependencies and installed position must be matched before substitution.

For installation, retain the IFM AS-Interface SmartLink receiving position, connector or terminal arrangement and configuration record. After power restoration, review diagnostics and test the affected operating path before process release.

The Smart Link DP AC1335 AS-i PROFIBUS-DP Gateway is supplied only after the complete hardware identity, condition and current OEM lifecycle status have been confirmed.
IFM Smart Link DP AC1335 AS-i PROFIBUS-DP Gateway Manual(Datasheets), LinkImportant Notice: The uploaded PDF documents the listed model or its identified product family. Confirm the complete order code, hardware revision and installed-system requirements before replacement. Accessories, cables, software and certificates are included only when stated in the quotation. All prices are shown in USD.

Bus Interface: Smart Link DP AC1335 performs the as-i profibus-dp gateway function within the IFM AS-Interface SmartLink. The retained documentation identifies gateway function as AS-Interface to PROFIBUS-DP; apply that value only to this documented execution.

Match the complete label, hardware form and functional position before transferring any setting, cable or termination from the removed unit.

Platform Match: approve Smart Link DP AC1335 only for the documented IFM AS-Interface and PROFIBUS-DP network. Compare rack, carrier or panel generation, connector keying, terminal numbering and all paired assemblies with the installation drawings.

Photograph both sides and the installed position before removal so revision markings, jumpers, addressing and channel allocation can be reconstructed accurately.

Startup Review: isolate the equipment, remove stored energy and inspect the receiving hardware before installing Smart Link DP AC1335.

Restore power in the approved sequence, review status and diagnostics, then test every affected control, signal, relay, communication, protection or monitoring path against the commissioning record.

Technical notes

Smart Link DP AC1335 must be selected and serviced as the exact as-i profibus-dp gateway identified by its complete hardware marking. Preserve the IFM AS-Interface SmartLink receiving position, connected hardware, configuration record and every affected control, I/O, communication, protection or monitoring dependency during replacement.

Network Inspection

Verify that the supplied item is marked Smart Link DP AC1335 and that its as-i profibus-dp gateway form, faceplate, connectors and printed revision agree with the approved IFM AS-Interface SmartLink receiving record.

Retained product evidence for this execution includes Gateway Function: AS-Interface to PROFIBUS-DP; AS-i Masters: 1 integrated master. Use photographs of the label and installed position to resolve ambiguity before shipment or installation.

Compatibility Record

For Smart Link DP AC1335, provide the installed IFM AS-Interface and PROFIBUS-DP network, required condition, quantity, receiving slot or mounting position and every connected terminal, cable or carrier assembly.

Record revision restrictions, configuration or calibration dependencies, testing requirements and required certificates so the quoted as-i profibus-dp gateway matches the maintenance scope.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    Bare-item dimensions from the IFM product datasheet: 85 x 138 x 68 mm. Final packed dimensions are confirmed after packing.
  • Packed shipping weight
    Confirmed after final packing
    Bare-item net weight from the IFM product datasheet: 0.396 kg. Final packed weight is confirmed after packing.
  • HS / customs code
    HS code 8517623990
    Indicative China HS classification for data communication gateway; final classification is confirmed by the customs declarant.
  • Country of origin
    Germany
    Origin is verified against the supplied item and applicable manufacturer documentation.
  • Ships from
    Xiamen, Fujian, China
    The dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Invoice, packing-list and origin-document requirements are agreed with the order.
PRODUCT & ORDER FAQS

Questions buyers ask about Smart Link DP AC1335

  • How is the exact Smart Link DP AC1335 execution confirmed?

    Read the complete Smart Link DP AC1335 marking, including every suffix and companion code, then compare the faceplate, connectors and installed-system record before approval.
  • Which installed platform must Smart Link DP AC1335 match?

    It must match the IFM AS-Interface and PROFIBUS-DP network, including the receiving rack, carrier or panel generation and the approved project configuration.
  • Which function does Smart Link DP AC1335 perform in the system?

    Smart Link DP AC1335 performs the documented as-i profibus-dp gateway role within the IFM AS-Interface SmartLink; do not transfer the role from a visually similar part number.
  • Which gateway function applies to Smart Link DP AC1335?

    The retained documentation records gateway function as AS-Interface to PROFIBUS-DP; verify the supplied execution carries the same specification.
  • Which interfaces should be checked before fitting Smart Link DP AC1335?

    Compare connector keying, terminal numbering, field supply, grounding, shielding, cable assemblies and every paired termination against the approved drawings.
  • Which configuration records are needed for Smart Link DP AC1335?

    Retain the slot or node assignment, channel map, firmware or logic dependencies, calibration data where applicable, and the approved IFM AS-Interface SmartLink project record.
  • How should Smart Link DP AC1335 be tested after installation?

    Restore power in the approved sequence, review status and diagnostics, then function-test every affected channel, relay, network, control, protection or monitoring path.
  • Can another revision replace Smart Link DP AC1335 without review?

    No direct interchangeability should be assumed. Compare the full code, as-i masters (1 integrated master), operating voltage (26.5 to 31.6 V DC from AS-i) and receiving-system documentation first.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Confirm the current OEM lifecycle stage for Smart Link DP AC1335 against manufacturer records at quotation. The supplied as-i profibus-dp gateway is matched by its complete hardware identity, revision and included assemblies.

    Any alternative is proposed only after the receiving IFM AS-Interface and PROFIBUS-DP network, interfaces, configuration dependencies and commissioning requirements have been reviewed.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

Smart Link DP AC1335
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.