ProSoft MVI56E-MNETXT
ProSoft MVI56E-MNETXT
ProSoft MVI56E-MNETXT
ProSoft MVI56E-MNETXT
ProSoft MVI56E-MNETXT
ProSoft MVI56E-MNETXT
· Product image is representative; revision or series may vary. Contact us to request a specific version.

MVI56E-MNETXT

Network Interface Communications Module
In Stock

Product Information:

serves as a robust Modbus TCP/IP client

and server enhanced network interface

module. It is designed to fit into either

local or remote racks and supports

complex data transfer configurations.

Expand All
Collapse all

Technical specifications for MVI56E-MNETXT

  • Manufacturer:
    ProSoft
  • Product Category:
    PLC System
  • Estimated shipping dimensions:
    3.4x14.2x14.5cm
  • Weight:
    0.26 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Product Line:
    ControlLogix
  • Product Type:
    Communications Module
  • Rack Type:
    Local or Remote
  • Protection:
    Conformal-coated
  • Ethernet Port:
    10/100 Base-T
  • Shock:
    30g Operational
  • Backplane Current Load:
    800 mA @ 5V DC
  • Stock:
    30

Revisions

Revision Part #

Also known as

MVI56E-MNETXT/A
MVI56E-MNETXT Ser A, Series A, Rev A

Information

Overview Manuals Principle Industrial Use Cases

Features:

  • Network Interface Communications Module
  • A powerful Modbus TCP/IP client/server enhanced network interface
  • Can be installed locally or remotely in a rack and supports complex data transfer configurations
The Allen-Bradley MVI56E-MNETXT is a fully-featured network interface module designed for Modbus TCP/IP communication. This single-slot module enhances connectivity for both local and remote rack applications. It excels at handling data transmission via ladder logic programming, simplifying user operation and facilitating integration into existing systems.

The module features a 10/100 Base-T Ethernet port for standardized and reliable network communication. A key feature is its user-customizable memory mapping capability, allowing up to 5,000 registers to be mapped to meet specific application needs, thus enhancing data management flexibility.

The MVI56E-MNETXT PROSOFT Network Interface Communications Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
PROSOFT MVI56E-MNETXT Network Interface Communications Module Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The module employs a conformal coating to effectively resist environmental factors. This coating protects the module from moisture and contaminants, improving its reliability in harsh environments. In terms of durability, the module can withstand shocks up to 30g, making it suitable for dynamic industrial environments. Finally, it consumes only 800 mA of backplane current load at 5V DC, making it ideal for a variety of power distribution schemes common in industrial control applications.
Remote Oil and Gas Sites: Monitor and control wellheads, pipelines, and pumping stations in outdoor or un-air-conditioned environments.
Wastewater Treatment: Interface with instruments and actuators in corrosive chemical environments.
Data Centralization: Act as a gateway between ControlLogix processors and up to 10 Modbus servers (slaves) or clients (masters) with 100 commands.
Infrastructure and Utilities: Manage Modbus-compatible meters, protective relays, and RTUs in outdoor substations.

Ask our team:

  • How does the MVI56E-MNETXT optimize real-time data throughput in complex Ethernet/IP networks? The MVI56E-MNETXT leverages high-speed protocol processing and integrated buffering to maximize deterministic communication efficiency across multi-node network architectures. Q2. Why is the MVI56E-MNETXT essential for ensuring synchronized motion control in industrial automation systems? By supporting precise packet scheduling and time-stamped messaging, the MVI56E-MNETXT enables coordinated control of distributed I/O and motion devices with minimal latency. Q3. What mechanisms does the MVI56E-MNETXT employ to maintain robust network integrity under high-traffic conditions? The MVI56E-MNETXT integrates advanced error detection, redundant path handling, and priority-based traffic management to preserve signal fidelity and reduce packet loss. Q4. How does the MVI56E-MNETXT facilitate seamless integration with Rockwell Automation controllers and third-party devices? Its comprehensive EtherNet/IP stack, modular configuration interface, and backward-compatible firmware enable the MVI56E-MNETXT to interoperate reliably with diverse control architectures. Q5. Why is adaptive network diagnostics a critical feature of the MVI56E-MNETXT? The module continuously monitors link quality, latency, and error metrics, allowing the MVI56E-MNETXT to provide predictive maintenance insights and reduce unplanned network downtime. Q6. How does the MVI56E-MNETXT ensure deterministic communication in time-sensitive applications? Through prioritized message routing, timestamped packet handling, and optimized internal scheduling, the MVI56E-MNETXT guarantees precise timing for control-critical operations. Q7. What design elements of the MVI56E-MNETXT enhance electromagnetic compatibility and reduce interference susceptibility? Shielded connectors, robust grounding schemes, and EMI-resistant circuit layouts in the MVI56E-MNETXT minimize noise impact, ensuring reliable data integrity in electrically noisy environments. Q8. How does the MVI56E-MNETXT manage simultaneous multiple client connections without performance degradation? By utilizing multi-threaded processing and intelligent packet queuing, the MVI56E-MNETXT efficiently handles concurrent sessions while maintaining low latency and consistent throughput. Q9. Why is proper configuration critical to leveraging the full capabilities of the MVI56E-MNETXT? Accurate IP addressing, subnet planning, and device parameter tuning are essential to ensure that the MVI56E-MNETXT functions optimally within complex industrial network topologies. Q10. How does the MVI56E-MNETXT support predictive diagnostics for long-term network reliability? By continuously logging communication statistics and analyzing performance trends, the MVI56E-MNETXT provides actionable insights for preventive maintenance, reducing operational disruptions.
    The MVI56E-MNETXT leverages high-speed protocol processing and integrated buffering to maximize the efficiency of deterministic communication in multi-node network architectures.
  • Why is the MVI56E-MNETXT crucial for ensuring synchronized motion control in industrial automation systems?
    The MVI56E-MNETXT supports precise packet scheduling and timestamped messaging, enabling coordinated control of distributed I/O and moving devices with minimal latency.
  • What mechanisms does the MVI56E-MNETXT employ to maintain robust network integrity under high-traffic conditions?
    The MVI56E-MNETXT integrates advanced error detection, redundant path handling, and priority-based traffic management to maintain signal fidelity and reduce packet loss.
  • How does the MVI56E-MNETXT ensure deterministic communication in time-sensitive applications?
    Through prioritized message routing, timestamped packet processing, and optimized internal scheduling, the MVI56E-MNETXT guarantees precise timing control for critical operations.
  • Which design elements of the MVI56E-MNETXT enhance electromagnetic compatibility and reduce interference sensitivity?
    The MVI56E-MNETXT employs shielded connectors, a reliable grounding scheme, and an electromagnetic interference-resistant circuit layout to minimize noise impact and ensure reliable data integrity even in electrically noisy environments.
  • Why is proper configuration crucial to fully leveraging the capabilities of the MVI56E-MNETXT?
    Accurate IP address allocation, subnetting, and device parameter tuning are essential to ensuring optimal performance of the MVI56E-MNETXT in complex industrial network topologies.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.