Allen-Bradley 1746-P4
Allen-Bradley 1746-P4
Allen-Bradley 1746-P4
Allen-Bradley 1746-P4
Allen-Bradley 1746-P4
Allen-Bradley 1746-P4
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Thursday, November 5
Fast Shipping Available
SLC 500 Chassis Power Supply

1746-P4

Product Information:

1746-P4 is an Allen-Bradley SLC 500 chassis power supply that accepts 120 or 240 V AC input and supplies the 5 V DC and 24 V DC rails used by compatible SLC modules.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      1746-P4 is an Allen-Bradley SLC 500 chassis power supply for compatible 1746 modular controllers and I/O assemblies. It accepts the documented 120 or 240 V AC input and provides regulated 5 V DC and 24 V DC power to modules through the SLC backplane. Correct selection depends on the chassis arrangement, total backplane current demand, branch protection, wiring and any required power-supply redundancy strategy.

      Selection basis

      Match the complete 1746-P4 identity, installed system, revision, connections and application before replacement.
    • INDUSTRY APPLICATIONS

      Where is it used?

      Typical industries using compatible systems and the documented product function are shown below.

      Industrial Manufacturing

      Powers compatible SLC 500 processors and I/O used in automated production machinery.

      Packaging

      Supports SLC control chassis installed in filling, labeling, conveying and packaging lines.

      Material Handling

      Supplies backplane power for compatible SLC racks controlling conveyors, sortation and storage equipment.

      Water & Wastewater

      Supports legacy SLC control panels used for pumping, treatment and distribution processes.
Technical specifications for

1746-P4

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Allen-Bradley
  • Product Category:
    PLC and Machine Control
  • Input Voltage:
    85 to 132 / 170 to 265 V AC
  • Input Frequency:
    47 to 63 Hz
  • Typical Line Power:
    240 VA
  • Maximum Inrush Current:
    45 A
  • Backplane Output:
    10.0 A at 5 V DC; 2.88 A at 24 V DC
  • User Power Output:
    1 A at 24 V DC
  • Operating Temperature:
    0 to 60 °C
  • Stock Availability:
    1
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Revisions

Revision Part #

Also known as

1746-P4/A
1746-P4 Ser A, Series A, Rev A

Alternative Names

1746P4 1746 P4 SLC 500 P4 power supply

Information

Overview Manuals Backplane Capacity AC Input Wiring Replacement Checks

Features:

  • Wide AC input ranges support documented 120 V and 240 V branch circuits.
  • Provides up to 10.0 A at 5 V DC and 2.88 A at 24 V DC to the SLC backplane.
  • Includes a 24 V DC, 1 A user supply for compatible external circuitry.

The 1746-P4 supplies regulated power to the processor and I/O modules installed in a compatible SLC 500 chassis. It accepts either the documented 120 V or 240 V AC input range and delivers up to 10.0 A at 5 V DC and 2.88 A at 24 V DC through the backplane, with a separate 24 V DC, 1 A user-power output available for supported field use.

Because every installed SLC module draws from one or both backplane rails, the supply is selected by a chassis-level power calculation rather than by physical fit alone. The input-voltage selection, branch protection, protective earth, typical line-power demand, maximum inrush current and total 5 V and 24 V loads must be checked before the supply is placed in service.

The 1746-P4 Allen-Bradley SLC 500 Chassis Power Supply may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Allen-Bradley 1746-P4 documentation and reference links.Important Notice: The linked PDF is an official manufacturer document for this model or its documented exact product family. Confirm the complete order code, revision, connected hardware and installation requirements before replacement. Accessories, software and certificates are included only when stated in the written quotation.

Calculate the total 5 V and 24 V current required by every installed SLC module before approving the supply.

Confirm the 120 or 240 V branch circuit, terminal arrangement, protective earth, disconnect and overcurrent protection.

Match the complete catalog and series, inspect the chassis connector and verify both backplane rails after installation.

Technical notes

1746-P4 is an SLC 500 chassis supply. Verify the complete series, AC input, branch protection, protective earth and both 5 V and 24 V backplane-current calculations before energization.

SLC 500 Backplane Power

1746-P4 accepts 85 to 132 or 170 to 265 V AC at 47 to 63 Hz and provides up to 10.0 A at 5 V DC plus 2.88 A at 24 V DC to a compatible SLC 500 backplane. A separate 24 V DC, 1 A user output is also provided.

Installation and Load Verification

Confirm the 120 or 240 V input selection, 240 VA typical line-power requirement, 45 A maximum inrush current, branch protection, protective earth and the separate 5 V and 24 V chassis load calculations before installation.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No official exact-model packed dimensions are published; final dimensions are recorded after protective packing.
  • Packed shipping weight
    Recorded net product weight
    0.225 kg. Recorded exact-model net product weight; final gross shipping weight is confirmed after protective packing.
  • HS / customs code
    8537101190
    The final customs classification is confirmed by the destination customs declarant.
  • Country of origin
    Mexico
    The existing exact-model record lists Mexico; confirm the supplied unit marking and shipment documents before dispatch.
  • Ships from
    Xiamen, Fujian, China
    The dispatch location, quantity and handling time are confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Invoice, packing-list and origin-document requirements are agreed with the order.
PRODUCT & ORDER FAQS

Questions buyers ask about 1746-P4

  • How is the 1746-P4 selected for an SLC 500 chassis?

    Add the 5 V DC and 24 V DC current required by every installed processor and I/O module, then confirm both totals remain within the supply's separate backplane ratings.
  • Which AC input ranges can be connected to the 1746-P4?

    The supply accepts 85 to 132 V AC or 170 to 265 V AC at 47 to 63 Hz when the input selection and terminal wiring are configured correctly.
  • How much current can the 1746-P4 deliver on the 5 V DC rail?

    It provides up to 10.0 A at 5 V DC to the compatible SLC 500 backplane.
  • How much current is available on the 24 V DC backplane rail?

    It provides up to 2.88 A at 24 V DC for installed modules that draw from that rail.
  • What is the purpose of the separate 24 V DC user output?

    The documented 1 A user output can power supported external circuits, but its use and load must remain separate from the chassis backplane calculation.
  • Which incoming-power values affect branch-circuit design?

    Use the documented 240 VA typical line-power requirement and 45 A maximum inrush current when selecting wiring, disconnects and protective devices.
  • What should be inspected before replacing an existing SLC power supply?

    Check the complete catalog and series, input selection, protective earth, terminal condition, chassis connector and the 5 V and 24 V load calculation.
  • Which measurements confirm correct operation after energizing the 1746-P4?

    Verify the chassis power indicators and both backplane rails under the installed load before enabling the processor and field equipment.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    1746-P4 is supplied only after the complete model, revision, condition and included hardware are checked against the written quotation.

    Confirm the 120 or 240 V input selection, 240 VA typical line-power requirement, 45 A maximum inrush current, branch protection, protective earth and the separate 5 V and 24 V chassis load calculations before installation.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

1746-P4
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.