Thermocouple Input Limit Alarm

G128-0001

Product Information:

G128-0001 is a Eurotherm Ultra SlimPak thermocouple input limit alarm with dual setpoints and SPDT relay outputs. It provides configurable temperature trip points for documented industrial thermal processes.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      G128-0001 is a Eurotherm / Action Instruments Ultra SlimPak thermocouple-input limit alarm with cold-junction compensation, one or two field-configurable setpoints and two SPDT relay outputs. It accepts documented B, E, J, K, R, S and T thermocouple ranges and uses a 9 to 30 VDC supply. Match the complete model, thermocouple type and range, HI or LO trip direction, failsafe selection, deadband, wiring and relay load before replacement.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Applications describe qualified industry use and do not replace exact input-range, relay-load or process-safety approval.

      Heat Treatment

      Thermocouple limit alarming in documented furnaces, ovens and thermal-processing equipment.

      Food & Beverage

      Temperature limit monitoring in qualified cooking, drying and thermal utility systems.

      Glass Manufacturing

      High- and low-temperature alarm duties in documented glass melting and forming processes.

      Plastics & Extrusion

      Thermocouple limit supervision in qualified barrels, dies and heating zones.
Technical specifications for

G128-0001

0 TECHNICAL PARAMETERS
  • Manufacturer:
    Eurotherm
  • Product Category:
    General Automation
  • Product type:
    Thermocouple input limit alarm
  • Product family:
    Ultra SlimPak G Series
  • Supported thermocouples:
    B, E, J, K, R, S and T
  • Setpoints:
    Single or dual, field configurable
  • Trip selection:
    HI or LO per setpoint
  • Failsafe selection:
    Failsafe or non-failsafe
  • Relay outputs:
    2 SPDT (2 Form C), one per setpoint
  • Relay rating at 120 VAC:
    5 A resistive
  • Relay rating at 240 VAC:
    2 A resistive
  • Relay rating at 28 VDC:
    5 A resistive
  • Supply range:
    9 to 30 VDC
  • Power consumption:
    1.5 W typical, 2.5 W maximum
  • Deadband adjustment:
    0.25% to 5% of full-scale input
  • Isolation:
    1800 VDC between contacts, input and power
  • Operating temperature:
    0 to 55 °C
  • Stock Availability:
    1
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

Action Instruments G128-0001 Eurotherm G128-0001 Ultra SlimPak G128-0001

Information

Overview Manuals Thermocouple Ranges Trip & Failsafe Setup Relay Commissioning

Features:

  • Thermocouple-input limit alarm with cold-junction compensation.
  • One or two configurable setpoints with HI or LO trip selection.
  • Two SPDT relay outputs with selectable failsafe operation.

G128-0001 is a DIN-rail Ultra SlimPak alarm module for thermocouple temperature inputs. The complete model, thermocouple type, configured input range, trip direction, failsafe selection, deadband and relay load must match the installed application.


Before removal, record the switch settings, setpoint and deadband adjustments, terminal wiring, thermocouple polarity, power supply and relay loads. After installation, verify cold-junction compensation, input indication, both trip points, reset behavior and every connected alarm or shutdown function under an approved test procedure.


The G128-0001 Eurotherm Thermocouple Input Limit Alarm is listed as Obsolete / Discontinued by OEM. Current revision, availability and supplied scope are confirmed in the written quotation.
G128-0001 official product documentation, Link

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

Configure the documented B, E, J, K, R, S or T thermocouple range with the module switches before calibration. Match the thermocouple type, span, polarity and cold-junction compensation requirements of the installed loop.

Each setpoint may be configured for HI or LO operation with adjustable deadband. Confirm the failsafe or non-failsafe selection, burnout direction and relay behavior required by the approved alarm philosophy.

Apply a calibrated thermocouple signal and verify both setpoints, LED indication, relay transfer, reset behavior and connected alarm circuits. Use external suppression for inductive relay loads as documented by Eurotherm.

Technical notes

Use G128-0001 only after the thermocouple type and range, trip direction, failsafe selection, setpoints, deadband, DC supply, relay loads and terminal wiring have been verified. Record every switch and adjustment position before removal, then test both alarm channels with a calibrated thermocouple source before return to service.

Input & setpoint configuration

Match the complete G128-0001 identity, thermocouple type and range, HI or LO trip direction, burnout direction, failsafe selection, setpoint and deadband settings. Record all switch and adjustment positions before removal.

Power, relay & calibration checks

Verify the 9 to 30 VDC supply, terminal polarity and both relay loads. After warm-up, use a calibrated thermocouple source to check cold-junction compensation, input indication, trip accuracy, relay reset and connected alarm functions.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    No verified exact-model warehouse dimensions were found; packed dimensions are recorded after protective packing.
  • Packed shipping weight
    Confirmed after final packing
    No verified exact-model warehouse weight was found; final gross shipping weight is recorded after protective packing.
  • HS / customs code
    Confirmed for the destination
    Final classification depends on the declared item and destination.
  • Country of origin
    Confirmed from supplied item
    Verified from the product nameplate or traceable documentation.
  • Ships from
    Confirmed in the written quotation
    Dispatch location depends on the allocated stock item.
  • Customs documents
    Confirmed for the destination
    Available documentation is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about G128-0001

  • How is the exact G128-0001 configuration verified?

    Match the complete model, nameplate, thermocouple type and range, switch settings, setpoint adjustments and installed wiring.
  • Which thermocouple inputs are supported?

    The documented G128 ranges cover B, E, J, K, R, S and T thermocouples; verify the configured range before replacement.
  • What supply and relay ratings must be checked?

    Verify the 9 to 30 VDC supply and each SPDT relay load against the documented AC or DC contact rating.
  • What should be recorded before removal?

    Record switch positions, HI or LO trip selection, failsafe mode, setpoints, deadband, thermocouple polarity, terminals and relay loads.
  • What should be checked during installation?

    Confirm DIN-rail mounting, DC polarity, thermocouple type and polarity, terminal assignment and external protection for inductive relay loads.
  • What should be tested after installation?

    Apply a calibrated thermocouple signal and verify indication, both trip points, reset behavior, failsafe response and connected alarm functions.
  • What should be inspected on arrival?

    Inspect the G128-0001 marking, housing, terminals, adjustment controls, included accessories, packaging and visible shipping condition.
  • What information is required for a quotation?

    Provide the complete model, quantity, condition, destination, thermocouple range and clear nameplate and terminal photographs.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Obsolete / Discontinued by OEM

    Moore Automated supplies verified G128-0001 Eurotherm units, inspects each exact item before shipment and supports stable industrial temperature alarming while reducing unexpected production downtime.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

G128-0001
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.