Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
The General Electric 8811-IO-DC-01 is a 8-channel, 24vdc, non-isolated, safety-rated discrete input/output module for the GE PAC8000 platform. It performs its documented signal, control or interface function within the installed system. Confirm the complete model code, hardware revision, interfaces and supplied condition against the installed equipment before replacement.
Verify that the supplied item is marked 8811-IO-DC-01 and that its 8-channel, 24vdc, non-isolated, safety-rated discrete input/output module form, connectors and revision agree with the approved GE PAC8000 receiving record.
For 8811-IO-DC-01, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.
Apply only parameters supported by the exact 8811-IO-DC-01 record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.
8811-IO-DC-01 technical scope: Special Capabilities: Discrete or pulsed outputs; Current Consumption: 70mA System Pwr; 50mA Field Pwr; Input Ratings / Output Ratings: On-Off 0.9mA / 2ADC/pt; 6ADC/module; Mixed I/O Count, Type, Speed: 8 Point Safety; Configurable I/O; 1-8mS Configurable; Series: GE PAC8000.
Use these values only for the listed hardware execution and verify the supplied label before installation.
Match 8811-IO-DC-01 to the approved GE PAC8000 receiving position, connector or terminal arrangement and configuration record.
After power restoration, review diagnostics and test the affected 8-channel, 24vdc, non-isolated, safety-rated discrete input/output module path.
Active / Available from OEM
8811-IO-DC-01 is a General Electric 8-channel, 24vdc, non-isolated, safety-rated discrete input/output module associated with the GE PAC8000 platform. It interfaces the documented field signals with the control system through the assigned channels, terminals and installed I/O position. Correct selection depends on the complete model code, connector or terminal arrangement, hardware revision and receiving-system configuration. Before replacement, compare the original product label, installed slot or cabinet reference, connected assemblies and approved project records. After installation, review system diagnostics and function-test every affected channel, control path, protection function or communication link before returning the equipment to service.