Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China

Honeywell's control-hardware guide identifies TK-FTEB01 as the coated Fault Tolerant Ethernet (FTE) Bridge for supported C200 controller or FIM-only chassis communication. It describes one bridge per such chassis. The reviewed guide does not map the additional 51309512-175 number or give environmental ratings; verify the physical label and network architecture.
Honeywell's R301.1 control-hardware guide describes an FTE Bridge module with model numbers TC-FTEB01 and TK-FTEB01. The nearby manufacturer's note says model prefixes beginning TK denote coated versions. The bridge supports communication over Honeywell's Fault Tolerant Ethernet between server-side resources and C200 controllers or FIM-only chassis in the specified architecture. The guide limits the installation to one bridge per C200 controller or FIM-only chassis. This is more precise than the previous generic Ethernet-module wording and should not be expanded into unsupported claims about Modbus conversion, Ethernet speed or port count.
For replacement planning, identify the complete TK-FTEB01 marking and check the site's additional 51309512-175 number against the allocated unit and Honeywell parts record; the reviewed guide does not cross-reference it. Record the C200 or FIM-only chassis, FTE connections, network diagnostics, redundancy state and configuration before an authorized change. Follow the manufacturer's installation procedure for the actual release and the plant's network-change controls. After fitting an approved spare, verify bridge recognition, server-to-controller or FIM communications, diagnostics and controlled network resilience tests. The historical planning guide does not establish current lifecycle, hot-swap permission or environmental ratings for the exact part.
Honeywell names TK-FTEB01 together with TC-FTEB01 as a Fault Tolerant Ethernet Bridge. The guide explains communication between the server and C200 controllers or FIM-only chassis over Honeywell FTE. The TK prefix denotes coating. Do not confuse this network bridge with an I/O Link Interface, a generic Ethernet switch or an arbitrary protocol converter merely because all are communications hardware.
Honeywell's documented architecture allows one FTE Bridge module per C200 controller or FIM-only chassis. The source does not map the additional 51309512-175 number from this site's title, so inspect the physical label and manufacturer parts record. Confirm the approved chassis, slot, network connections and system release; a broad reseller description does not establish interchangeability with an uncoated TC unit or another FTE module.
Record current FTE diagnostics, topology, partner communication and controller/FIM state before an authorized module change. Follow Honeywell's release-specific procedure and site network change control. After fitting an approved replacement, verify module recognition, server communications, alarms and planned network-resilience checks. The reviewed guide does not provide vibration, shock, altitude or data-rate ratings for the exact model and does not authorize hot swapping.
Confirm the installed C200 controller or FIM-only chassis and the associated Honeywell FTE communication path before selecting TK-FTEB01. Honeywell's guide states one FTE Bridge per such chassis and identifies the TK variant as coated. Check the complete 51309512-175 physical marking, module revision, supported slot and system release in a manufacturer parts record. Do not infer generic switch, Modbus or field IO-Link functions from the bridge name.
Capture topology, network health, server links, controller or FIM diagnostics and approved configuration before work. Follow Honeywell's exact-release installation procedure and the site's change-control and isolation rules. After fitting the approved coated bridge, verify recognition, communications and redundancy or resilience behavior using a controlled acceptance plan. The planning guide does not establish current lifecycle or permit energized replacement.