Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
10201/2/1 is a Honeywell safe digital output module for the Honeywell FSC safety system. The documented identity places it in the Honeywell FSC product family and defines its role as safe digital output module within the installed control or monitoring architecture.
10201/2/1 is a Honeywell safe digital output module for the Honeywell FSC safety system. The documented identity places it in the Honeywell FSC product family and defines its role as safe digital output module within the installed control or monitoring architecture.
The listed parameters are limited to the documented model or product-family evidence. Do not import ratings from a similar part number; compare the exact label, slot or carrier, terminal map and connected equipment.
10201/2/1 must remain matched to the documented Honeywell FSC safety system installation. Confirm the receiving hardware generation, connector or terminal arrangement, software or configuration dependencies and system drawings before approving the item.
Photograph labels and connections before removal and preserve the original position, keying, addressing and channel allocation.
Isolate the equipment using the approved procedure, verify all stored energy is removed and inspect the receiving hardware before fitting 10201/2/1.
After installation, restore power in the documented sequence, review diagnostics and test every affected signal, relay, network, control or protection function against the commissioning record.
Inspect the supplied safe digital output module for 10201/2/1 against the documented product record. Confirm Power requirements: 5 V DC, 25 mA and Number of output channels: 8 channels, then check the label, housing, connectors and mounting points for the exact installed execution.
Before returning 10201/2/1 to service, preserve Output specification: 24 V DC solid-state source, short-circuit proof and Maximum current: 550 mA from the installed arrangement. After fitting the item, exercise each documented output with a controlled load and confirm channel indication and fail-state behavior; record the result with the maintenance history.
Obsolete / Discontinued by OEM. The exact 10201/2/1 identity, revision and included hardware are confirmed against the supplied item.
Moore Automated can provide the documented safe digital output module subject to stock and condition. Any alternative or upgrade is quoted only after the receiving system, connectors, configuration and commissioning requirements have been reviewed.