Product Information:

The MVI69-MNET is a single-slot backplane interconnect Modbus TCP/IP network communication module developed by ProSoft Technology specifically for Rockwell Automation's Allen-Bradley CompactLogix series (based on the 1769 bus) PLC processors.

The MVI69-MNET is installed as a bridge in the PLC's local or remote I/O rack, utilizing a backplane communication mechanism similar to ordinary I/O modules to establish a bidirectional data exchange channel between the CompactLogix controller and an external Ethernet network.

The MVI69-MNET is widely used in hybrid industrial automation systems with high protocol compatibility requirements, such as in manufacturing, oil and gas refining, power dispatching, and food processing industries. In terms of system architecture, this module features powerful protocol conversion and dual-role processing capabilities, natively supporting simultaneous operation as a Modbus TCP/IP client (client/master) and server (server/slave).

Expand All
Collapse all

Technical specifications for MVI69-MNET

  • Manufacturer:
    ProSoft
  • Product Category:
    PLC System
  • Estimated shipping dimensions:
    15 x 12.3 x 14 cm
  • Weight:
    0.36 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    USA
  • Place of shipment:
    Xiamen, Fujian, China
  • Category Series:
    CompactLogix
  • Product Type:
    Communication Module
  • Registers:
    5000 max.
  • Client Commands:
    100 max.
  • Current Load:
    800 mA max. @ 5 VDC
  • Communication:
    Modbus TCP/IP
  • Relative Humidity:
    5% to 95% (with no condensation)
  • Operating Temp.:
    0°C to 60°C (32°F to 140°F)
  • Storage Temp.:
    -40°C to 85°C (-40°F to 185°F)
  • Stock:
    120

Revisions

Revision Part #

Also known as

MVI69-MNET/A
MVI69-MNET Ser A, Series A, Rev A

Alternative Names

MVI69MNET MVI69 MNET MV169-MNET MVI69-MNETC MVI69MNETC MVI69 MNETC MV169-MNETC MVI69E-MBTCP MVI69L-MBS MVI69L-MBTCP MVI69-PDPMV1

Information

Overview Manuals Practical Application Use Cases

Features:

  • Modbus TCP/IP Communication Module
  • Single-slot 1769 CompactLogix chassis module, powered entirely via the backplane (draws 800 mA at 5.1 Vdc)
  • Natively supports simultaneous operation as a Modbus TCP/IP Client (Master) and a Modbus TCP/IP Server (Slave)
The MVI69-MNET is a Modbus TCP/IP communication module from ProSoft Technology. It can connect to Rockwell Automation's CompactLogix or MicroLogix processors. A compatible power supply is required for installation. An empty slot must be provided in the chassis for installation. The module requires 800 mA of current.

When installing the MVI69-MNET, it is recommended to follow the installation instructions in the manufacturer's manual and comply with local safety regulations. Power to the system and peripheral devices must be turned off before connecting the module to the chassis. Before powering on, ensure all connections are secure and correct.

The MVI69-MNET PROSOFT Modbus TCP/IP Communication Module may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
PROSOFT MVI69-MNET Modbus TCP/IP Communication Module Manuals(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The MVI69-MNET is widely used in factory workshops to establish deterministic multi-vendor bridging:
 
Multi-brand PLC crosstalk: As an uncompressed network channel, it enables CompactLogix processors to directly poll data or issue control commands to Schneider Electric Modicon PLCs or Siemens controllers configured as Modbus TCP servers.
 
Sub-device cluster integration: Deployed as a centralized data acquisition unit for monitoring dedicated peripheral devices such as frequency converters (VFDs), instruments, flow meters, and SCADA monitoring nodes.
 
Legacy grid migration: Allows legacy remote terminal units (RTUs) or engine management panels communicating via Modbus TCP to transmit real-time tank diagnostics or pump control data to new Rockwell controller tags.

Technical notes

The ProSoft Technology MVI69-MNET is a single-slot Modbus TCP/IP baseband communication module designed specifically for Rockwell Allen-Bradley CompactLogix and MicroLogix 1500 systems. It serves as an asynchronous I/O module between the PLC processor and Ethernet, featuring 5000 virtual registers of 16-bit words. Supporting 10/100 Base-T high-speed network communication, it can function as either a Modbus TCP/IP client (master) or server (slave). Offering 1500 Vrms of electrical isolation and broadcast storm protection, it operates stably in industrial environments from 0°C to 60°C, enabling seamless integration of third-party Modbus devices with Rockwell automation architectures.
  • Product Lifecycle Stage

    Active/Available from OEM

    Moore Automated provides high-quality ProSoft replacement modules and spare parts to support existing and legacy automation systems. With reliable products and fast delivery, we help customers maintain stable system operation and simplify equipment maintenance.

Ask our team:

  • How does the MVI69-MNET facilitate deterministic Modbus TCP/IP communication between ControlLogix processors and heterogeneous industrial automation networks?
    The MVI69-MNET is a high-performance communication interface module designed to provide seamless Modbus TCP/IP client and server connectivity for Rockwell Automation CompactLogix and ControlLogix platforms. The MVI69-MNET supports deterministic industrial data exchange between Ethernet-based automation infrastructures.
  • Why is the MVI69-MNET considered a critical industrial protocol gateway for deterministic Ethernet communication in complex automation environments?
    The MVI69-MNET enables robust integration between PLC systems and Modbus TCP/IP devices, ensuring reliable data acquisition, monitoring, and distributed process automation across industrial networks.
  • How does the MVI69-MNET maintain communication reliability under high network traffic and harsh industrial operating environments?
    The MVI69-MNET employs optimized Ethernet communication processing, configurable polling strategies, industrial-grade hardware design, and deterministic protocol management to maintain stable network performance.
  • How does the MVI69-MNET enhance industrial data acquisition architectures by simultaneously functioning as a Modbus TCP/IP client and server?
    The MVI69-MNET can function as both a Modbus TCP/IP client and server, enabling flexible bidirectional communication between PLCs, HMIs, SCADA systems, drives, analyzers, and third-party field devices.
  • Why do engineers need to verify compatibility between the MVI69-MNET, CompactLogix processors, Ethernet switches, SCADA platforms, and Modbus TCP/IP field devices before deployment?
    Proper system verification ensures that the MVI69-MNET maintains deterministic communication performance while supporting reliable data exchange in industrial networks.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.