3SK2122-1AA10

SIRIUS safety relay Basic unit
In Stock

Product Information:

SIRIUS safety relay Basic unit 3SK2 series

20 F-DI, 4 F-DQ, 2 DQ, 24 V DC Can be

parameterized via SIRIUS Safety ES 45 mm width

screw terminal up to SILCL 3 (DIN EN 62061)

Up to Performance Level E (ISO 13849-1) Output

expansions 3SK1 and fail-safe motor

starters 3RM1 via device connector connectable

Expand All
Collapse all

Technical specifications for 3SK2122-1AA10

  • Manufacturer:
    Siemens
  • Product Category:
    PLC System
  • Estimated shipping dimensions:
    15.2 x 20 x 10 cm
  • Weight:
    0.25 kg
  • Tariff Code:
    8537101190
  • Country of origin:
    Germany
  • Place of shipment:
    Xiamen, Fujian, China
  • Category Series:
    SIRIUS
  • Operating power rated value:
    4.5 W
  • Amount of data of the cyclic user data for inputs with PROFIBUS DP:
    64 bit
  • Control supply voltage rated value:
    24 V DC
  • Input delay time:
    0 ... 150 ms
  • Input current at digital input:
    2.6 mA
  • Residual current maximum:
    0.05 mA
  • Total current maximum:
    7 A
  • Voltage drop maximum:
    0.5 V
  • Stock:
    5

Information

Overview Manuals In terms of operation Availability and Expansion

Features:

  • SIRIUS safety relay Basic unit 3SK2 series 20 F-DI, 4 F-DQ, 2 DQ,24 V DC
  • Parametrically configurable via SIRIUS Safety ES
  • Complies with SILCL Level 3 (DIN EN 62061) standards, achieving the highest performance level E (ISO 13849-1)
The 3SK2122-1AA10 is a programmable safety repeater (software configurable) in the Siemens SIRIUS series. As a core control unit for safety applications, it can flexibly integrate various safety devices, such as emergency stop buttons, safety door locks, light curtains, and laser scanners.

SIRIUS safety relay Basic unit 3SK2 series 20 F-DI, 4 F-DQ, 2 DQ, 24 V DC Can be parameterized via SIRIUS Safety ES 45 mm width screw terminal up to SILCL 3 (DIN EN 62061) Up to Performance Level E (ISO 13849-1) Output expansions 3SK1 and fail-safe motor starters 3RM1 via device connector connectable

The 3SK2122-1AA10 Siemens SIRIUS safety relay Basic unit may still be available for purchase and support from Moore Automated Company beyond End-Of-Life (EOL) by the manufacturer (OEM).
Siemens 3SK2122-1AA10 SIRIUS safety relay Basic unit datasheet(Datasheets), Link Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.
The 3SK2122-1AA10 employs a dual-channel redundant monitoring mechanism. It continuously scans input signal levels and pulse test signals via its internal microprocessor to detect short circuits, open circuits, or synchronization errors in the circuit. Once a trigger signal (e.g., pressing an emergency stop button) is detected at the input or a logic judgment fails to meet safety conditions, the processor will shut down the safety output with a millisecond-level response time, forcing the device into a safe stop state by cutting off the power to the actuator (e.g., a contactor or frequency converter).
Current Status: This product is currently available in the Siemens product portfolio. Modular Expansion: Seamless expansion is possible via device connectors using the SIRIUS 3SK1 output expansion module and 3RQ1 coupling relay, significantly reducing manual wiring.

Ask our team:

  • What essential safety functions does the 3SK2122-1AA10 implement in modern machine safety architectures?
    The 3SK2122-1AA10 is a safety relay designed to reliably monitor emergency stop circuits and safety devices, enabling the machine to quickly transition to a safe state upon detection of a hazardous situation.
  • Why is the 3SK2122-1AA10 considered a key component in functional safety systems?
    The 3SK2122-1AA10 is designed to meet stringent functional safety standards, ensuring reliable shutdown performance and minimizing risks in safety-related control systems.
  • How does the 3SK2122-1AA10 support emergency stop and safety door monitoring applications?
    The 3SK2122-1AA10 continuously monitors input circuits from emergency stop buttons, safety doors, and protective devices, verifying circuit integrity before allowing the machine to operate.
  • What input architecture defines the safety monitoring capabilities of the 3SK2122-1AA10?
    The 3SK2122-1AA10 provides dual-channel safety inputs, supporting cross-circuit monitoring and fault detection for high diagnostic coverage.
  • Which output configuration makes the 3SK2122-1AA10 suitable for safety-critical shutdown circuits?
    The 3SK2122-1AA10 features safety-grade relay outputs designed to reliably interrupt hazardous machine movement or power.
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore automated please read our privacy policy.
Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.