Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
Vibro-Meter TQ902-011 111-902-000-011 is a standard-mount eddy-current proximity sensor configured as A1-B1-C40-D2-E5000-F0-G0-H05. Match the M10 x 1 body, 40 mm body length, 2 mm unthreaded length, 5 m integral cable and unprotected execution before replacement.
TQ902-011 111-902-000-011 is a standard-mount high-temperature eddy-current proximity sensor for shaft relative vibration and gap or axial-position measurement. The complete A1-B1-C40-D2-E5000-F0-G0-H05 order string defines the environment, M10 x 1 mounting body, 40 mm geometry, integral cable, optional protection and total measurement-chain execution. Selection must also match the documented EA902 extension cable, IQS900 signal conditioner, required 2 or 4 mm range, target material and monitoring-channel scaling.
Before removal, record the installed probe gap, thread engagement, locknut position, cable routing, connector condition and every associated channel setting. Reproduce the mechanical position and matched measurement chain from the controlled machine record rather than from appearance or another TQ9x2 suffix. After installation, verify gap voltage, polarity, linear response, diagnostics, alarm settings and every affected machinery-protection path before returning the equipment to service.
A1-B1-C40-D2 specifies the standard-environment M10 x 1 body, 40 mm body length and 2 mm unthreaded length. Confirm probe engagement, locknut position and target clearance.
E5000-F0-G0-H05 identifies the 5 m integral-cable execution without optional hose protection. Protect the cable routing and connector while preserving the documented 5 m chain.
Match TQ902 with the documented EA902 extension cable and IQS900 signal conditioner. Confirm 2 or 4 mm range, voltage or current output, total chain length and channel scaling.
TQ902 is an 8.2 mm standard-mount eddy-current sensor. The exact order code defines the M10 x 1 body, 40 mm body length, 2 mm unthreaded section and cable-protection execution.
Record the installed gap, thread engagement, locknut position and cable path before removal. Reproduce the mechanical position without assuming another TQ9x2 suffix is interchangeable.
The official TQ902 chain supports a 2 or 4 mm linear range with DC to 20 kHz response according to its matched IQS900 configuration. Sensor operating temperature is -40 to +180 C and the sensor head protection rating is IP68.
Verify the EA902 cable, IQS900 range and output, total chain length, target material and monitoring-channel scaling. Confirm diagnostics before returning the machine to service.
The cited official data sheet documents TQ902 and order number 111-902-000-011 but does not state a formal OEM lifecycle stage.
Moore Automated can quote the exact A1-B1-C40-D2-E5000-F0-G0-H05 execution subject to confirmed availability, condition and included components. Any proposed alternative must be checked against the complete order code, EA902 and IQS900 measurement chain, mechanical installation and controlled machine record; no drop-in replacement is asserted.