Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
CI871AK01 is an ABB profinet io communication interface kit used with the documented ABB Advant OCS platform. Selection must match the complete product identity, hardware execution, connected assemblies and approved system configuration.
Before replacing CI871AK01, compare the supplied nameplate, revision, connectors or terminals and installed position with the original equipment record. After installation, review diagnostics and complete the approved functional checks before service.
ABB CI871AK01 documentation and reference links.
Important Notice: Every linked document must identify the listed model or its documented family. Confirm the complete order code, hardware revision and installed-system requirements before replacement.
CI871AK01 serves as the documented PROFINET IO master interface for the confirmed AC 800M configuration.
Compare the CEX-Bus position, TP867 base, station names, device topology, IP settings and redundancy design.
Preserve the controller project and network plan, then verify interface status and device communication after installation.
Engineering check: Commission CI871AK01 as a IO master on PROFINET IO. Match the controller hardware configuration, station name, IP subnet, update interval and RJ45 port assignment before downloading the control project.