Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China

The General Electric IC694ALG222 is a input module, analog 16 point single ended/8 channel differential, voltage. for PACSystems RX3i industrial automation applications. Documented product details include 16-Channel Analog Voltage Input Module; provides 16 single-ended (or eight); differential input channels; RX3i Universal Backplane; an external source of Isolated +24 VDC. Confirm the complete model code, hardware revision and supplied condition against the installed equipment before replacement.
Verify that the supplied item is marked IC694ALG222 and that its input module, analog 16 point single ended/8 channel differential, voltage. form, connectors and revision agree with the approved PACSystems RX3i receiving record.
For IC694ALG222, state the required condition, quantity, installed position, connected assemblies and document requirements in the written enquiry.
Apply only parameters supported by the exact IC694ALG222 record or a documented family source. Do not infer electrical ratings or interchangeability from appearance.
IC694ALG222 technical scope: No. of channels: 16 single-ended or 8 differential; Voltage Range: -10 to +10 V, 0 to 10 V; Calibration: Factory calibrated; Update Rate: 6 msec(all 16), 3 msec(all 8); Input Filter Response: 41 Hz, 82 Hz.
Use these values only for the listed hardware execution and verify the supplied label before installation.
Match IC694ALG222 to the approved PACSystems RX3i receiving position, connector or terminal arrangement and configuration record.
After power restoration, review diagnostics and test the affected input module, analog 16 point single ended/8 channel differential, voltage. path.
Active / Available from OEM
IC694ALG222 is a General Electric input module, analog 16 point single ended/8 channel differential, voltage. associated with the PACSystems RX3i platform. It interfaces the documented field signals with the control system through the assigned channels, terminals and installed I/O position. Correct selection depends on the complete model code, connector or terminal arrangement, hardware revision and receiving-system configuration. Before replacement, compare the original product label, installed slot or cabinet reference, connected assemblies and approved project records. After installation, review system diagnostics and function-test every affected channel, control path, protection function or communication link before returning the equipment to service.