Registered Address: 32D Floor Guomao Building, No.388, Hubin South Road, Siming District, Xiamen,Fujian, China
IS200VTURH2BAC is a GE turbine protection i/o board engineered for the GE Mark VI and Mark VIe Speedtronic turbine-control system. It performs the documented turbine protection i/o board function within the GE Mark VI / Mark VIe hardware architecture, so the complete order code, hardware execution and receiving position must be retained during selection.
IS200VTURH2BAC is a GE turbine protection i/o board engineered for the GE Mark VI and Mark VIe Speedtronic turbine-control system. It performs the documented turbine protection i/o board function within the GE Mark VI / Mark VIe hardware architecture, so the complete order code, hardware execution and receiving position must be retained during selection.
The listed parameters are limited to the documented model or product-family evidence. Compare the complete label, receiving hardware, terminal map and connected equipment rather than transferring ratings from a nearby code.
IS200VTURH2BAC must remain matched to the documented GE Mark VI and Mark VIe Speedtronic turbine-control system installation. Confirm hardware generation, slot or carrier, connector or terminal arrangement, software or configuration dependencies and system drawings before approval.
Photograph labels and connections before removal and preserve the original position, keying, addressing and channel allocation.
Isolate the equipment using the approved procedure, verify stored energy is removed and inspect the receiving hardware before fitting IS200VTURH2BAC.
After installation, restore power in the documented sequence, review diagnostics and test every affected signal, relay, network, control, safety or monitoring function against the commissioning record.
Inspect the supplied turbine protection i/o board for IS200VTURH2BAC against the documented product record. Confirm Product Type: Turbine Protection I/O Board and Category Series: Mark VI IS200, then check the label, housing, connectors and mounting points for the exact installed execution.
Before returning IS200VTURH2BAC to service, preserve Voltage Supply: 125 V dc and Common Mode Voltage Range: +5 V from the installed arrangement. After fitting the item, apply controlled field signals and compare channel indication, scaling, diagnostics and alarm response; record the result with the maintenance history.
Lifecycle status is confirmed against current manufacturer records at quotation. The exact IS200VTURH2BAC identity, hardware revision and included assemblies are checked against the supplied item.
Any replacement or migration option is proposed only after the receiving GE Mark VI and Mark VIe Speedtronic turbine-control system, connectors, configuration dependencies and commissioning requirements have been reviewed.