Request a Parts Quote
Name
Company *
Phone *
Email *
Address
City
State / Province / Region
Zipcode
Country
Quantity *
Part Number *
Manufacturer
Preferred Condition
Additional Information
Cancel
HIMA F3238
HIMA F3238
HIMA F3238
HIMA F3238
HIMA F3238
HIMA F3238
  • ISO 9001:2015 Certified

    Our quality management system covers sourcing,testing and dispatch
  • View Our Success Stories

    Real stories from real customer orders
In Stock
Ships by Thursday, November 12
Fast Shipping Available
Ex(i) Safety Input Module

F3238

Product Information:

F3238 is a HIMA HIQuad eight-channel digital input module for NAMUR proximity switches or resistor-network contacts in intrinsically safe circuits. It supports line-break and short-circuit monitoring, SIL 3 safety functions and hazardous-area field devices. Confirm the complete module revision, approved cable plug and installed HIQuad execution before replacement.

Product image is representative; revision or series may vary. Contact us to request a specific version.
  • One-year warranty
  • Global shipping
  • Exact-model verification
    • PRODUCT OVERVIEW

      What is this product?

      HIMA F3238 evaluates eight NAMUR proximity switches or contacts with resistor networks in intrinsically safe circuits. The module provides open-circuit and short-circuit monitoring for safety-related input loops and is listed for SIL 3 applications. Selection must match the exact module revision, H41q/H51q or HIQuad X architecture, approved Ex cable plug, field-loop design and installed software function block.

      Source boundary

      Exact-model hardware values shown here are qualified from public technical cross-references and require order-stage confirmation.
    • APPLICATIONS

      Where it may be used

      Applications describe qualified uses of the exact product and do not replace system engineering or functional-safety approval.

      Oil & Gas

      Emergency-shutdown and fire-and-gas input loops using approved intrinsically safe field devices.

      Chemical Processing

      SIL 3 process-safety inputs for qualified hazardous-area switches and contacts.

      Power Generation

      Safety interlocks and monitored trip inputs in documented turbine and balance-of-plant systems.

      Marine & Offshore

      Intrinsically safe shutdown and alarm inputs in approved offshore and marine installations.
Technical specifications for

F3238

0 TECHNICAL PARAMETERS
  • Manufacturer:
    HIMA
  • Product Category:
    Safety Automation
  • Product type:
    Eight-channel digital input module for intrinsically safe circuits
  • Compatible platform:
    HIMA H41q/H51q and supported HIQuad X architectures
  • Safety capability:
    Up to SIL 3 in an approved safety function
  • Input channels:
    8
  • Supported field devices:
    NAMUR proximity switches or contacts with resistor network
  • Line monitoring:
    Open-circuit and short-circuit monitoring
  • Nominal sensor supply:
    Approximately 8.2 V DC
  • Switching time:
    Approximately 10 ms
  • 0-signal input current:
    0.35 to 1.2 mA
  • 1-signal input current:
    2.1 to 6.0 mA
  • Wire-break threshold:
    0.28 mA or less
  • Short-circuit threshold:
    6.5 mA or more
  • Maximum line impedance:
    50 ohms
  • Maximum documented line length:
    1000 m with 0.5 mm² conductor
  • Module supply demand:
    5 V DC at 150 mA and 24 V DC at 100 mA
  • Rack space:
    8 space units
  • Ambient temperature:
    0 to +60 °C
  • Installation protection:
    Module and connections installed to at least IP20
  • Stock Availability:
    8
WHAT HAPPENS NEXT?

From enquiry to delivery

Six clear steps show what information is required and what the written quotation will contain.
  • 01

    Find the product

    Search the part number or send an inquiry for obsolete, discontinued or hard-to-find parts.
  • 02

    Provide the details

    Share the exact part number, quantity, condition, revision, destination and any required certificates or photos.
  • 03

    Review the quotation

    Receive price, currency, condition, availability, warranty, lead time, shipping terms and quotation validity in writing.
  • 04

    Confirm the order

    Accept the quotation in writing and complete the required payment before shipment.
  • 05

    Pay by bank transfer

    Pay the full invoiced amount by bank wire in RMB/CNY, GBP, EUR or USD using the official invoice details.
  • 06

    Verify and dispatch

    The item receives a pre-shipment inspection and suitable protective packaging. Functional testing is performed only where appropriate equipment and procedures are available for the specific item. We confirm the applicable inspection scope and provide tracking after dispatch.
BUYER INFORMATION

Product condition level information

Commercial details are confirmed in writing before payment.
  • 01

    Factory Sealed

    Unused product with the original factory seal intact; packaging age or storage marks may still be present.

  • 02

    Original Pack

    Unused product in original manufacturer packaging that was not originally factory sealed.

  • 03

    Factory New

    New and current product sourced through the manufacturer or authorized supply channel when expressly confirmed in the quotation.

Alternative Names

HIMA F 3238 HIQuad F3238 F3238 Ex(i) Input Module HIMA 93 3238 300 Input Module

Information

Overview Manuals Input & Line Monitoring Intrinsic Safety HIQuad Integration

Features:

  • Exact F3238 identity and product function.
  • Verified order-code-specific electrical and system details.
  • Replacement requires complete installed-system matching.
HIMA F3238 evaluates eight NAMUR proximity switches or contacts with resistor networks in intrinsically safe circuits. The module provides open-circuit and short-circuit monitoring for safety-related input loops and is listed for SIL 3 applications. Selection must match the exact module revision, H41q/H51q or HIQuad X architecture, approved Ex cable plug, field-loop design and installed software function block.

Before replacement, record the complete label, installed position, wiring, accessories and retained configuration. After installation, verify diagnostics and every affected function under an approved controlled procedure.

The HIMA F3238 8-Channel Ex(i) Safety Input Module is listed as Active / Available from OEM. Current revision, availability and supplied scope are confirmed in the written quotation.
HIMA F3238 8-Channel Ex(i) Input Module Data Sheet, Link

Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. All prices are shown in USD.

F3238 evaluates eight NAMUR proximity switches or resistor-network contacts. Each commissioned loop must be checked against the documented 0-signal, 1-signal, wire-break and short-circuit current ranges. Unused inputs assigned in the HIMA function block require the documented termination so that false line-error messages are avoided.

The field circuits are intrinsically safe only when the approved Ex installation, cable plug, separation distances, conductor identification and associated apparatus are used. The module itself is installed outside the hazardous area. A module previously used in a general electrical circuit must not later be reassigned to an Ex(i) application.

Match the F3238 revision, rack position, operating-system compatibility and HIMA function block to the installed H41q/H51q or supported HIQuad X system. Record the cable-plug execution and all field-loop terminations before removal. After installation, verify diagnostics and prove every affected safety input under an approved commissioning procedure.

Technical notes

Use F3238 only after the complete manufacturer identity, ratings, installed architecture, wiring and retained configuration have been verified. Preserve the approved system design, isolate all energy sources before work, and complete documented functional testing before return to service.

Installation & Configuration Verification

Verify the complete F3238 identity, hardware revision, rack slot, HIMA operating-system execution, HB-RTE-3 or approved successor logic, Ex cable plug and field-loop drawing before replacement. Maintain the required separation between intrinsically safe and non-intrinsically safe wiring and use only approved installation practices.

Input Circuit & Diagnostic Limits

The documented input thresholds distinguish normal open and closed states from wire break and short circuit. Confirm sensor current, loop resistance, line length and resistor network for every channel. After installation, test the safe state, active state and both line-fault diagnostics without bypassing the approved safety function.

Customs & shipping dimensions / weight

  • Packed shipping dimensions
    Confirmed after final packing
    The matching exact-model warehouse record lists net dimensions of 4 x 19 x 12.8 cm before final protective packing.
  • Packed shipping weight
    Confirmed after final packing
    The matching exact-model warehouse record lists a net weight of 0.3 kg before final protective packing.
  • HS / customs code
    Confirmed for the destination
    Final classification depends on the declared item and destination.
  • Country of origin
    Confirmed from supplied item
    Verified from the product nameplate or traceable documentation.
  • Ships from
    Xiamen, Fujian, China
    Dispatch location is confirmed in the written quotation.
  • Customs documents
    Confirmed for the destination
    Available documentation is stated in the written quotation.
PRODUCT & ORDER FAQS

Questions buyers ask about F3238

  • How is the exact F3238 identified?

    Match the complete F3238 marking, manufacturer label, hardware or coil execution and installed-system requirements before replacement.
  • Can a nearby family model be substituted?

    No direct interchangeability is assumed. Verify the complete order code, electrical ratings, terminals, accessories, software or starter configuration and approved system documentation.
  • What should be recorded before removal?

    Record the complete nameplate, installed position, wiring, connectors, accessories, configuration or protection settings and all field labels before disconnecting the item.
  • What should be checked before installation?

    Confirm the exact order code, supply and signal ratings, terminal arrangement, environmental execution, accessories and compatibility with the documented system design.
  • What should be tested after installation?

    Verify power, diagnostics, wiring and every affected input, output, contact or safety function under an approved controlled commissioning procedure.
  • Are accessories included automatically?

    Only accessories expressly identified in the written quotation are included. Confirm plugs, terminal blocks, cables, mounting hardware and documentation separately.
  • Which documents should be retained?

    Retain the supplied label photographs, order code, quotation, inspection record, configuration backup and applicable manufacturer manual for future maintenance.
  • What information is needed for a quotation?

    Provide the complete model, quantity, required condition, destination and clear nameplate or connector photos together with any certificate, accessory or inspection requirements.
MORE PARTS IN THE SAME PROJECT?

Search another part number

Use the exact manufacturer number where possible.
WHY BUYERS WORK WITH MOORE AUTOMATED

Clear checks before you commit

Product-specific verification and written commercial details help purchasing and maintenance teams reduce mismatch risk.
  • Pre-shipment inspection

    Products are inspected before dispatch to verify model, condition and applicable specifications.
  • Documentation available

    Product photos, packaging photos, certificates and datasheets can be provided when available.
  • Clear commercial terms

    Condition, warranty, lead time, included items and shipping terms are stated clearly in writing.
  • 20+ years of experience

    Over 20 years of experience in industrial automation and hard-to-source legacy parts.
  • Product Lifecycle Stage

    Active / Available from OEM

    HIMA currently lists F3238 in the HIQuad X I/O portfolio and identifies it as an eight-channel SIL 3 digital input module for proximity switches and Ex(i) circuits. Exact revision, system compatibility, certificates, accessories and supplied scope are confirmed in the written quotation.

Trusted by 5,000+ plants worldwide | Backed by our vast inventory of top-tier control parts, drives and servo motors, fast shipments are dispatched to cover your urgent needs. ABOUT US >>
Moore Disclaimer: Moore Automated's sales automation equipment and related solutions are intended for industrial automation and business operational efficiency improvement purposes only. Product information, technical parameters, and application cases are for reference only and do not constitute an absolute guarantee of performance for any specific industry, scenario, or final application. Actual equipment performance may vary depending on factors such as the usage environment, system integration method, and maintenance conditions. Users should confirm compatibility and safety based on professional technical assessments. Moore Automated assumes no liability for any direct or indirect losses caused by improper use, modification, or failure to operate according to specifications, to the extent permitted by law.

Get a quick price for:

F3238
Quantity
Upload
(gif, jpg, jpeg, png, bmp, doc, docx, xls, xlsx, ppt, pdf, csv)
For more information on how your data is processed and stored by Moore Automated please read our privacy policy.