MU-TAOX12 51304335-100 is a Honeywell analog output fta for the Honeywell Experion PKS and Series C I/O. The documented identity places it in the Honeywell Series C / Experion PKS product family and defines its role as analog output fta within the installed control or monitoring architecture.
MU-TAOX12 51304335-100 is a Honeywell analog output fta for the Honeywell Experion PKS and Series C I/O. The documented identity places it in the Honeywell Series C / Experion PKS product family and defines its role as analog output fta within the installed control or monitoring architecture.
The listed parameters are limited to the documented model or product-family evidence. Do not import ratings from a similar part number; compare the exact label, slot or carrier, terminal map and connected equipment.
MU-TAOX12 51304335-100 must remain matched to the documented Honeywell Experion PKS and Series C I/O installation. Confirm the receiving hardware generation, connector or terminal arrangement, software or configuration dependencies and system drawings before approving the item.
Photograph labels and connections before removal and preserve the original position, keying, addressing and channel allocation.
Isolate the equipment using the approved procedure, verify all stored energy is removed and inspect the receiving hardware before fitting MU-TAOX12 51304335-100.
After installation, restore power in the documented sequence, review diagnostics and test every affected signal, relay, network, control or protection function against the commissioning record.
Inspect the supplied analog output fta for MU-TAOX12 51304335-100 against the documented product record. Confirm Product Type: AO Redundant and AO Type: 8 Outputs, then check the label, housing, connectors and mounting points for the exact installed execution.
Before returning MU-TAOX12 51304335-100 to service, preserve Output Signal Perturbation During Swap: 1 ms nominal 4 ms maximum and Output Signal Perturbation During Failover: 30 ms nominal 125 ms maximum from the installed arrangement. After fitting the item, exercise each documented output with a controlled load and confirm channel indication and fail-state behavior; record the result with the maintenance history.
Confirm Current OEM Lifecycle Status. The exact MU-TAOX12 51304335-100 identity, revision and included hardware are confirmed against the supplied item.
Moore Automated can provide the documented analog output fta subject to stock and condition. Any alternative or upgrade is quoted only after the receiving system, connectors, configuration and commissioning requirements have been reviewed.